  "affected": [
    {
      "ranges": [
        {
          "database_specific": {
            "extracted_events": [
              {
                "introduced": "0"
              },
              {
                "fixed": "4.7"
              }
            ],
            "source": "AFFECTED_FIELD"
          },
          "events": [
            {
              "introduced": "0"
            },
            {
              "fixed": "a5313885d44c496ef0f5b8a689c84840e0f9e3fd"
            }
          ],
          "repo": "https://github.com/contiki-ng/contiki-ng",
          "type": "GIT"
        }
      ]
    }
  ],
  "aliases": [
    "GHSA-9rm9-3phh-p4wm"
  ],
  "database_specific": {
    "cna_assigner": "GitHub_M",
    "cwe_ids": [
      "CWE-120"
    ],
    "osv_generated_from": "https://github.com/CVEProject/cvelistV5/tree/main/cves/2022/35xxx/CVE-2022-35927.json"
  },
  "details": "Contiki-NG is an open-source, cross-platform operating system for IoT devices. In the RPL-Classic routing protocol implementation in the Contiki-NG operating system, an incoming DODAG Information Option (DIO) control message can contain a prefix information option with a length parameter. The value of the length parameter is not validated, however, and it is possible to cause a buffer overflow when copying the prefix in the set_ip_from_prefix function. This vulnerability affects anyone running a Contiki-NG version prior to 4.7 that can receive RPL DIO messages from external parties. To obtain a patched version, users should upgrade to Contiki-NG 4.7 or later. There are no workarounds for this issue.",
  "id": "CVE-2022-35927",
  "modified": "2026-07-15T01:48:55.998141807Z",
  "published": "2022-08-04T20:35:14Z",
  "references": [
    {
      "type": "WEB",
      "url": "https://github.com/contiki-ng/contiki-ng/pull/1589/commits/4fffab0e632c4d01910fa957d1fd9ef321eb87d2"
    },
    {
      "type": "ADVISORY",
      "url": "https://github.com/CVEProject/cvelistV5/tree/main/cves/2022/35xxx/CVE-2022-35927.json"
    },
    {
      "type": "ADVISORY",
      "url": "https://github.com/contiki-ng/contiki-ng/security/advisories/GHSA-9rm9-3phh-p4wm"
    },
    {
      "type": "ADVISORY",
      "url": "https://nvd.nist.gov/vuln/detail/CVE-2022-35927"
    },
    {
      "type": "FIX",
      "url": "https://github.com/contiki-ng/contiki-ng/pull/1589"
    }
  ],
  "schema_version": "1.8.0",
  "severity": [
    {
      "score": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
      "type": "CVSS_V3"
    }
  ],
  "summary": "Unverified DIO prefix info lengths in RPL-Classic in Contiki-NG"
}