Daylight factor

Learn how to calculate and improve the ratio of light level inside a structure to the light level outside. Find out the design guidance and software tools for daylighting assessment and simulation.

The daylight factor is the index that defines the correct ventilation and lighting of a dwelling. Discover why it is important and how it is calculated.
Daylight Factor

Daylight Factor (DF) is defined as the ratio of daylight illumination at a specific point on a plane, due to both direct and indirect light from the sky, to the illumination on a horizontal plane under an unobstructed hemisphere of the same sky. It is expressed as a percentage and is used to assess the amount of natural light in a space, excluding direct sunlight. AI generated definition based ...
Daylight factor (DF) is a daylight availability metric that expresses as a percentage the amount of daylight available inside a room (on a work plane) compared to the amount of unobstructed daylight available outside under overcast sky conditions (Hopkins,1963). The key building properties that determine the magnitude and distribution of the daylight factor in a space are (Mardaljevic, J ...

Free Daylight Factor Calculator
Free daylight factor calculator for architects and lighting designers. Calculate DF = Ei/Eo × 100%, sky component, internally reflected component. Check LEED v4.1 sDA 300/50%, WELL, and EN17037 daylight requirements. Glass type presets, material finishes, skylight support, and interactive DF probe tool. Try it free!
For purposes of calculating daylight factors associated with beam solar illuminance, the direct normal solar illuminance is taken to be 1.0 W/m 2. The actual direct normal solar illuminance, determined from direct normal solar irradiance from the weather file and empirically-determined luminous efficacy, is used in the time-step calculation.

Daylight Factor Calculator
The Daylight Factor Calculator estimates how much useful daylight reaches an interior space by comparing indoor daylight illuminance with simultaneous outdoor daylight illuminance under a standard overcast-sky assumption. It returns the daylight factor as a percentage and also shows indoor illuminance and outdoor reference illuminance. This calculator is intended for daylight adequacy ...
4 The implications of using Daylight Factor as the basis for assessing compliance with Building Codes/Regulations and/or Environmental assessment Method Credits. 5 What are the alternatives to Daylight Factor ? 5.1 Daylight Autonomy 5.2 Useful Daylight Illuminance 5.3 Cumulative illuminance 6 Conclusion 7 Acknowledgement 8 Other definitions

How to Calculate Daylight Factor
Daylight factor thresholds differ across jurisdictions because codes are calibrated to local sky conditions. The UK and Australia regulate to a 2% floor because their overcast reference skies deliver about 5,000 lux. Warmer climates have brighter skies (9,000-10,500 lux in hot humid regions), so codes there rely on glazing-area ratios or sky-component reach rules instead.





daylight factor [10.5.9.11] A measure of daylight illuminance at a point on a plane, expressed as the ratio of the illuminance at that point to the simultaneous exterior illuminance on a horizontal plane from an unobstructed sky of assumed or known luminance distribution (typically overcast).