Structural steel beam splice design is a critical aspect of construction engineering, enabling the connection of two steel beams to create a continuous structural element. This process involves careful calculation, selection of appropriate splice types, and adherence to relevant design standards. In this article, we will delve into the intricacies of structural steel beam splice design, providing a comprehensive guide for engineers and architects.
Understanding Steel Beam Splices
Steel beam splices are designed to transfer shear forces, bending moments, and normal forces between two connected beams. They are categorized into three types based on their function:
- Moment Splices: Transfer bending moments and shear forces.
- Shear Splices: Transfer shear forces only, with negligible moment transfer.
- End Splices: Transfer normal forces and shear forces, with minimal moment transfer.
Design Considerations
When designing steel beam splices, several factors must be considered:

Load Compatibility
The splice must be capable of transferring the applied forces at the beam ends. This involves checking the splice for adequate strength and stiffness to prevent excessive deformations.
Splice Type Selection
The choice of splice type depends on the beam size, loading, and available space. Common splice types include:
- Bolted Splices
- Welded Splices
- Overlapped Splices
- Through-Plate Splices
Material Properties
The yield strength, ultimate tensile strength, and modulus of elasticity of the beam and splice material must be considered in the design process.

Design Standards and Codes
Design of steel beam splices should comply with relevant building codes and standards, such as:
- American Institute of Steel Construction (AISC) 36th Edition
- American Society of Civil Engineers (ASCE) 7-16
- American Welding Society (AWS) D1.1
Design Procedure
The design procedure for steel beam splices involves the following steps:
Calculate Applied Forces
Determine the shear force (V), bending moment (M), and normal force (N) at the splice location using structural analysis software or manual calculations.

Select Splice Type
Choose an appropriate splice type based on the applied forces, beam size, and available space.
Size the Splice
Calculate the required splice size and plate thickness using the selected splice type and applied forces. Ensure the splice has adequate strength and stiffness to prevent excessive deformations.
Check Code Compliance
Verify that the design complies with relevant building codes and standards, such as AISC, ASCE, and AWS.
Example: Bolted Moment Splice Design
Let's consider an example of designing a bolted moment splice for a W14x90 beam with an applied bending moment of 120 kip-ft and shear force of 40 kips.
| Parameter | Value |
|---|---|
| Beam Size | W14x90 |
| Applied Moment | 120 kip-ft |
| Applied Shear | 40 kips |
| Bolt Size | 3/4" (M16) |
| Bolt Spacing | 6" (150 mm) |
| Number of Bolts | 5 |
| Plate Thickness | 1/2" (12.7 mm) |
Using the AISC 36th Edition, the design of the bolted moment splice can be checked for strength and stiffness, ensuring compliance with relevant code provisions.
In conclusion, the design of structural steel beam splices requires careful consideration of applied forces, splice types, material properties, and adherence to relevant design standards. By following the design procedure outlined in this article, engineers can create safe, efficient, and code-compliant steel beam splices for various construction applications.