Selecting the correct cable for a high-power shower is a critical safety decision, and the search for an "8.5 kw shower cable size screwfix" highlights the specific requirements needed to handle the significant electrical load. Screwfix, as a leading UK trade and DIY retailer, stocks various cables, but understanding the technical specifications is essential before placing an order. This guide breaks down the exact cable size required for an 8.5 kW shower unit, explaining the reasoning behind the specifications to ensure a safe and compliant installation.
Understanding Power Requirements for Showers
To determine the appropriate cable, you first need to understand the power rating of your shower. An 8.5 kW shower is considered a high-power appliance, drawing a substantial current from the electrical supply. Standard domestic lighting circuits or radial circuits protected by 16 or 20 amp breakers are entirely insufficient for this level of demand. Installing an undersized cable risks overheating, insulation damage, and potentially a fire, making the correct gauge non-negotiable for safety.
The Electrical Calculation
The cable size is dictated by the current (amps) the shower draws. Using the standard UK voltage of 230V, the calculation involves dividing the power (in watts) by the voltage. For an 8.5 kW unit, the math results in approximately 37 amps (8500 watts / 230 volts). This figure immediately rules out standard 1.5mm² or 2.5mm² cables, which are rated for much lower currents, and pushes the requirement firmly into the domain of thicker cables suitable for main ring circuits.

Recommended Cable Specifications for Screwfix
For a sustainable and safe installation of an 8.5 kW shower, the cable must be robust enough to handle the 37-amp draw with a comfortable safety margin. The industry standard and correct choice for this application is a 6.0mm² cable. This cross-sectional area provides the necessary current-carrying capacity and minimizes voltage drop over the length of the run. When searching on Screwfix, filtering for "6.0mm² cable" will yield the correct products, typically found in the wiring or cable accessories section.
Specific Products to Look For
On the Screwfix website or in their stores, you should be looking for specific types of 6.0mm² cable rather than just any 6mm option. The most common and suitable choices are:
- 100mm² Twin & Earth (T+E):This is the standard cable for shower circuits. It consists of three conductors (brown, blue, and green/yellow) within an outer sheath, providing phase, neutral, and earth protection.
- Mains Cable 6.0mm²:Ensure the product description specifies 6.0mm² and is approved for mains electricity.
Why 6mm² is the Standard for 8.5 kW Showers
While it might be tempting to opt for a 4.0mm² cable to save on materials, this is dangerous and violates electrical regulations for a load of this size. A 4mm² cable is generally rated for around 25-30 amps, which is far below the 37 amps an 8.5 kW shower demands. The 6mm² cable, however, is typically rated for 32-40 amps depending on the installation method and ambient temperature, placing it perfectly within the required range and ensuring longevity and safety.

Compliance and Safety Standards
Installing the correct cable size is not just a recommendation; it is a legal requirement under the UK Electrical Regulations (BS 7671). Using the wrong gauge can cause your circuit breaker to trip constantly, or worse, it can lead to cable overheating without warning. By choosing the appropriate 6.0mm² cable available at Screwfix, you ensure the installation passes building control inspections and complies with the Wiring Regulations, protecting both your property and your family.
Additional Considerations for Installation
Beyond just the cable size, there are other factors to consider when wiring an 8.5 kW shower. The cable length is a crucial variable; the longer the run from the consumer unit to the shower, the more the voltage can drop, potentially affecting performance. You may need to factor in slightly longer cable runs to compensate for this. Furthermore, ensure that the final circuit is protected by a Residual Current Device (RCD) and a suitable Miniature Circuit Breaker (MCB) rated for the specific current.
Summary of Specifications
When searching for the right hardware on Screwfix, condense the requirements into a simple checklist. An 8.5 kW shower demands a specific cable to operate safely and efficiently. Adhering to these specifications guarantees that your new shower operates at full power without overloading your home's electrical system.

| Parameter | Specification |
|---|---|
| Appliance Power | 8.5 kW |
| Calculated Current | ~37 Amps |
| Required Cable Size | 6.0mm² |
| Recommended Cable Type | Twin & Earth (T+E) |
| Protective Device | 32-40 Amp MCB |