Open riser stairs, characterized by the absence of solid material between treads, have become a popular design choice in modern architecture. However, the quest...
Open riser stairs, characterized by the absence of solid material between treads, have become a popular design choice in modern architecture. However, the question of whether stairs can have open risers often arises due to safety concerns and building codes. This article delves into the intricacies of open riser stairs, their safety implications, design considerations, and adherence to building codes.
Open riser stairs, also known as gap risers, feature treads that are not connected by a solid riser. Instead, the riser is open, allowing light to filter through and creating a visually appealing, airy effect. This design can enhance the aesthetic appeal of a space, making it appear more spacious and inviting. However, the open riser design also presents unique challenges, particularly in terms of safety.
Safety is a primary concern when considering open riser stairs. The open space between treads can pose a hazard, especially for young children, elderly individuals, or those with mobility challenges. The risk of accidents, such as tripping or falling, is higher with open riser stairs compared to traditional stairs with solid risers. Therefore, it's crucial to consider the potential risks and benefits before installing open riser stairs.

Another safety concern with open riser stairs is the risk of objects falling through the open space. This can be particularly problematic in homes with small children or pets, as toys, food, or other items could fall through the gaps, potentially causing damage or creating a choking hazard.
Building codes play a significant role in determining whether stairs can have open risers. The International Residential Code (IRC) and the International Building Code (IBC) both address the issue of open riser stairs. According to these codes, open risers are not permitted in residential construction, with the exception of certain decorative features that do not exceed 4 inches in height. However, commercial buildings may have more flexibility in their design, allowing for open riser stairs in some cases.
| Code | Open Riser Stair Requirements |
|---|---|
| International Residential Code (IRC) | Open risers are not permitted, except for decorative features not exceeding 4 inches in height. |
| International Building Code (IBC) | Open risers may be permitted in commercial buildings, subject to specific design and safety requirements. |
When designing open riser stairs, several factors should be taken into account to mitigate safety risks and ensure compliance with building codes.

The depth of the tread and the height of the riser play a crucial role in the safety and stability of open riser stairs. Treads should be deep enough to provide adequate support for the foot, while risers should be low enough to prevent tripping hazards. The IRC recommends a maximum riser height of 7 inches and a minimum tread depth of 10 inches.
Guardrails and handrails are essential safety features for open riser stairs. They help prevent falls and provide support for individuals using the stairs. According to the IRC, guardrails must be at least 42 inches high and capable of withstanding a load of 200 pounds applied in any direction. Handrails should be designed to provide a secure grip and be capable of withstanding a load of 200 pounds applied in a downward or outward direction.
Proper lighting is crucial for the safety of open riser stairs. Adequate lighting ensures that the stairs are visible and reduces the risk of accidents. The IRC recommends a minimum illumination level of 10 foot-candles for stairs, with additional lighting required for areas with low visibility or high traffic.

If open riser stairs are not suitable for your space due to safety concerns or building code restrictions, several alternatives can provide the same aesthetic appeal while addressing these issues.
Glass or wire mesh risers can create a similar open feel to open riser stairs while providing a solid surface that addresses safety concerns. These materials allow light to pass through, creating a visually appealing effect, while also providing the necessary support and stability.
Partial open risers, also known as half-open risers, feature a solid riser at the bottom of the stair and an open riser above it. This design provides some of the visual appeal of open riser stairs while addressing safety concerns by providing a solid surface at the bottom of the stair.
Open riser stairs can be a visually appealing and modern design choice, but they also present unique safety challenges and building code considerations. By understanding the intricacies of open riser stairs, their safety implications, and the relevant building codes, homeowners and designers can make informed decisions about whether stairs can have open risers in their specific situation. When designing open riser stairs, it's essential to prioritize safety and compliance with building codes to create a functional and visually appealing space.