Is your above ground well pump not performing as it should? Don't worry, you're not alone. Well pumps, like any other mechanical equipment, can develop issues over time. The good news is, many problems can be diagnosed and resolved with a bit of troubleshooting. Let's dive into some common above ground well pump issues and how to troubleshoot them.
Understanding Your Above Ground Well Pump
Before we start troubleshooting, it's essential to understand the basic components of an above ground well pump system. These typically include:
- Pump
- Pressure tank
- Control switch
- Power supply
- Piping and fittings
Common Above Ground Well Pump Issues
Now that we've covered the basics, let's look at some common problems you might encounter with your above ground well pump:

- Pump running constantly
- Low water pressure
- Air in the lines
- Pump not turning on
- Excessive noise
- Water leaks
Pump Running Constantly
If your pump is running non-stop, it's likely due to a problem with the pressure switch. Here's how to troubleshoot:
- Check the pressure switch settings. The cut-in pressure (when the pump turns on) should be lower than the cut-out pressure (when the pump turns off).
- Inspect the pressure switch diaphragm. If it's damaged or worn out, replace it.
- Ensure the pressure tank is functioning correctly. If it's not holding pressure, it may need to be replaced.
Low Water Pressure
Low water pressure can be caused by several issues:
- Clogged or worn-out pump impeller
- Air in the lines
- Leaks in the system
- Incorrect pressure switch settings
To troubleshoot, start by checking the pump impeller. If it's clogged or worn, replace it. Next, bleed the air from the lines. If that doesn't solve the issue, check for leaks and ensure your pressure switch settings are correct.

Air in the Lines
Air in the lines can cause a variety of issues, including low water pressure and pump running constantly. To bleed the air:
- Turn off the power to the pump.
- Open a faucet at the highest point in your home to allow air to escape.
- Slowly turn the power back on to the pump.
If air continues to be a problem, you may have a leak in your system that needs to be repaired.
Pump Not Turning On
If your pump isn't turning on, the first thing to check is the power supply. Ensure the circuit breaker hasn't tripped and that the pump is receiving power. If the power supply is fine, the problem could be with the control switch or the pump itself.

Excessive Noise
Excessive noise can be caused by a variety of issues, including a worn-out pump, air in the lines, or a problem with the pressure tank. To troubleshoot:
- Check the pump for any signs of wear or damage. If necessary, replace it.
- Bleed the air from the lines.
- Inspect the pressure tank for any signs of issues.
Water Leaks
Water leaks can occur in various places in your well pump system, including the pump, pressure tank, or piping. To find the leak:
- Turn off the power to the pump.
- Inspect the entire system for any signs of water.
- Once you've found the leak, repair it as necessary.
Remember, if you're unsure about any part of the troubleshooting process, it's always best to contact a professional. They have the tools and expertise to diagnose and repair any issues with your above ground well pump.