Selecting the correct spray nozzle tip is the single most critical decision when optimizing any liquid application process. From agricultural irrigation to precision cleaning and industrial coating, the nozzle dictates droplet size, spray pattern, and distribution uniformity. A spray nozzle tip chart serves as the essential map for navigating this complex landscape, translating technical specifications into actionable data for every user.
Decoding the Anatomy of a Spray Nozzle Tip Chart
At first glance, a spray nozzle tip chart can appear overwhelming, filled with cryptic numbers and abbreviations. However, understanding its structure is fundamental to making an informed choice. The chart is typically organized by brand and series, with each row representing a specific model designed for a distinct purpose. The core columns provide the technical specifications that define performance, including orifice size, flow rate, and the resulting spray pattern.
Key Specifications to Interpret
Two primary metrics dominate any reliable spray nozzle tip chart: Orifice Size and Flow Rate. The orifice, or nozzle hole, is measured in millimeters (mm) or thousandths of an inch, and it directly controls the volume of liquid passing through. Flow Rate, usually listed in gallons per minute (GPM) or liters per minute (LPM), indicates the volume of liquid the nozzle will consume at a given pressure. A larger orifice typically yields a higher flow rate and a coarser droplet, while a smaller orifice produces a finer mist with a lower flow rate.

The Critical Role of Spray Angle
Beyond size and volume, the spray nozzle tip chart must clearly define the spray angle, a parameter that dictates coverage. Angles range from a narrow, concentrated stream at 0-15 degrees to a full flat fan of 110 degrees or more. A narrow angle is ideal for spot-cleaning or deep penetration, whereas a wide angle provides broad, uniform coverage for painting or lawn care. Selecting the wrong angle can lead to overlapping waste or streaked, uneven results, making this specification paramount.
Material and Pressure Considerations
Durability is another pillar detailed within the chart, dictated by the materials used in construction. Charts will specify whether a nozzle is made of brass, stainless steel, or hardened polymers, each offering different levels of resistance to abrasion and chemical corrosion. Furthermore, every nozzle operates within a recommended pressure range, typically listed in PSI or bar. Exceeding this range not only alters the droplet size but can also damage the nozzle tip, leading to inconsistent performance and premature failure.
Matching the Chart to Your Application
Utilizing a spray nozzle tip chart effectively requires aligning the data with your specific task. For agricultural pesticide application, you need a cone nozzle that produces moderately coarse droplets to prevent drift and ensure foliage penetration. Conversely, an automotive painter requires a flat fan nozzle that yields a soft, edge-free glaze for a flawless finish. Referencing the chart allows you to systematically filter options based on these functional requirements rather than guesswork.

Visualizing the Data: A Sample Nozzle Comparison
To translate theory into practice, consider the following hypothetical data commonly found in a spray nozzle tip chart. This table illustrates how different configurations serve unique purposes.
| Nozzle Model | Orifice (mm) | Flow Rate (GPM @ 40 PSI) | Spray Angle | Recommended Use |
|---|---|---|---|---|
| TF-6 | 0.45 | 0.85 | 65° | General Purpose Spraying |
| SS-8 | 0.60 | 1.20 | 40° | Heavy-Duty Cleaning |
| DC-12 | 0.30 | 0.35 | 110° | Foliage Irrigation |
Maintaining Precision Over Time
Finally, a spray nozzle tip chart is not merely a selection tool but a reference for maintenance and troubleshooting. Over time, mineral deposits and debris can clog the orifice, altering the flow and pattern. By routinely checking the chart, technicians can identify when a nozzle is performing outside its specified parameters. Regular cleaning and timely replacement, guided by the original specifications, ensure that the application remains efficient, cost-effective, and consistent throughout the lifespan of the equipment.
□ Automatic spray alignment for sizes 10 and 15 with 25610-*-NYR Quick ... * Wide angle spray nozzle height is influenced by nozzle orientation. The ...
What Do The Numbers On Spray Nozzles Mean at Martha Porter blog
09.04.2026 ... ... nozzle size and spray pressure. Ensure travel speeds are reached at the correct pressure; most air-induced nozzles use about 60 to 70 psi.
Spray Tips Nozzles
Spray mist is reduced to a minimum. Patent-registered dual nozzle technology. Pre-atomiser nozzle (Pre-Tip) ... -No. Spray nozzle set for Fine-. Coat Gun. Nozzle ...
Teejet Spray Nozzle Chart at Angela Milligan blog
21.01.2016 ... For broadcast applications, W = nozzle spacing (distance between two nozzles on the boom) in inches. · For band spraying, W = band width in ...
ST Spray Nozzle Chart - RB Spraytech
STEP 1: Sizing Up Your Spray Tips. To “size up” a spray tip means to ensure the flow rate of a ...
The Key to Sprayer Nozzle Selection: How to Read Spray Nozzle Charts
08.10.2024 ... Nozzles affect spray quality and spraying efficiency. GRDC has two Standard Nozzle Selection Guides for standard boom sprays to help select ...
Toro Nozzle Charts | SprinklerDude®
23.05.2022 ... Spray tip sizes. Spray tips are numbered from 108 all the way to 1235. Lets look at some common spray tips for paint. If we tabulate the bore ...
Pressure Washer Nozzles | Quick Tips for Optimal Performance - Spraywell
For example an 02 nozzle is always yellow, and an 04 nozzle is always red. See the chart below for what all of the nozzle colours mean. Chart of nozzle tip ...
Nozzle Tips and Strainers - Pesticide Safety Education Program ...
25.02.2024 ... If you want to choose the correct size spray nozzle you need to know how to read a spray nozzle chart ... Understanding Sprayer Tip Charts. PR ...
How to Use a Nozzle Flow Chart, With a Surprising Twist | Sprayers 101
border nozzle OC. Backpack sprayer. Series ST only. Technical data: ISO. Nozzle sizes. 01 – 08. Spray angles. 80°, 110°. Materials. POM, ceramic, brass on ...
Graco Tips Color Chart – Graco Spray Tip Size Chart – CREM
28.06.2024 ... Chart displaying ISO nozzle color codes for various spray applications. Not all spray tips make it this easy. In some cases, spray tip numbers ...
Spray Nozzle Orifice Size Chart at Mary Baylor blog
... spray nozzles. The number will always be used when calculating MPH, GPA, and GPM. Now that you have GPM, you can look at the spray nozzle chart and find the GPM ...
Sprayer Tip Number Chart: Sprayer Tip Size Chart – MTSIVC
What is a High-Efficiency Nozzle? Typical nozzles – Un-Even Watering. With typical nozzles, part of the lawn may not have enough water and other ...
Spray Nozzle Chart Australia at Mackenzie Sheehy blog
of spray angle and nozzle sizes using TurboDrop® TD 80/60/40/20 nozzles (see ... • Nozzle tip and cap one piece, no fumbling when changing nozzles ...
Surface Cleaner Nozzle Chart and Guide - Spraywell
15.11.2019 ... This video is all about understanding tip charts. If you're spraying you need to know this not to mention it takes the guess work out of ...
High Efficiency Airless Sprayer Tip Chart - Wagner SprayTech
Each rear incline nozzle tip that is compatible with See & Spray Select is ... • When selecting straight down nozzle tips, use the generic nozzle tip sizes.
John Deere Sprayer Nozzles Guide at Eugene Bergeron blog
Nozzle application rate chart - Standard ISO tips. The majority of nozzles these days are manufactured to the ISO standard which means they have a common ...
Hypro Nozzles Chart – HYPRO ® SPRAY NOZZLE SELECTION GUIDE – TLWK
NOTE: When using nozzle tip table to select appropriate tip sizes for a specific application rate, you will seldom have a calculated need that fits a given.
Spray Nozzle Charts: Why They Are Important & How to Read Them ...
Airless spray tips will always have a 3 digit number on the side e.g. 415, 517 etc., the first number tells you what size the fan is and second 2 numbers are ...
Pressure Washer Nozzles Guide: Types, Sizes, And Tips – WATQVT
The first digit is half of the fan width, the "5" in "517" equals a 10 inch spray fan width (5 x 2 = 10) · The last two digits are the size of the tip opening in ...
Toro Nozzle Charts | SprinklerDude®