Selecting the correct cable for your kitchen extractor fan is a critical detail that significantly impacts both safety and performance. While it may seem like a minor component compared to the fan itself, using an inadequate or incorrectly specified cable can lead to overheating, voltage drop, or even pose a serious fire hazard. The cable must carry the necessary current to the motor without excessive resistance, ensuring the fan runs smoothly and reliably for years to come.
Understanding the Electrical Requirements
The first step in determining the right cable size is understanding the power needs of your specific extractor fan. These requirements are usually found on the manufacturer's label, typically located on the back or bottom of the unit. You need to identify two key figures: the power consumption measured in Watts (W) and the rated current measured in Amps (A).
Most modern domestic extractor fans operate on a standard 230V supply in the UK and Europe. To calculate the current draw, you divide the wattage by the voltage (Current(A) = Power(W) / Voltage(V)). For example, a 230W fan running on a 230V supply will draw approximately 1 Amp, while a more powerful 920W model will draw around 4 Amps. Always check the specific rating for your model rather than relying on generic assumptions.

Cable Sizing Based on Current Load
Once you know the current draw of your fan, you can select a cable that can safely handle that load. Standard electrical wiring relies on a system of American Wire Gauge (AWG) or cross-sectional area measured in square millimeters (mm²). For kitchen extractor applications, the cable size is primarily determined by the amperage of the circuit.
For the majority of residential extractor fans, which typically draw less than 5 Amps, a cable with a cross-sectional area of 1.5 mm² is generally sufficient. This size is commonly used for lighting circuits and small appliances, making it a reliable choice for low to medium power extraction units.
When to Use Thicker Cables
While 1.5 mm² cable works for most standard fans, there are scenarios where you must step up to a heavier gauge. If you are installing a high-performance industrial-style extractor, a unit with a heater function, or a very large ducting run that increases resistance, the current draw might exceed 5 Amps.

In these situations, a 2.5 mm² cable is the appropriate choice. This thicker conductor reduces the risk of overheating and ensures the fan receives the full voltage it needs to operate at full power. Always refer to the manufacturer’s wiring diagram, as some high-output models may explicitly require 2.5 mm² wiring to meet safety specifications.
The Role of Cable Composition
Beyond the physical thickness of the conductors, the material and construction of the cable are vital considerations. Solid core cables, which consist of a single piece of metal, are stiff and ideal for fixed installations where the cable remains stationary. These are perfect for wiring directly from a junction box to a wall-mounted switch.
On the other hand, stranded cable is composed of multiple thin wires twisted together. This design offers superior flexibility, making it the better option for scenarios where the connection might experience vibration, such as near a window or door that opens frequently. Stranded cable is also generally easier to terminate in standard electrical terminals without the wire fraying.
Wiring Configuration and Safety
How you route and terminate the cable is just as important as its physical dimensions. The cable must be protected from physical damage, which often means running it through conduit or trunking if it passes through areas where it could be nicked or pinched. You must never connect the extractor fan directly to a standard plug and socket; this method is unsafe and usually violates electrical regulations.
The connection should be made into a dedicated spur socket or, preferably, wired directly into the consumer unit via a switched fused spur. This ensures the power is controlled by a proper switch and protected by a correctly rated fuse. If you are unsure about the local wiring regulations in your area, consulting a certified electrician is the safest course of action to ensure compliance and safety.