* A variable represents a change on a equipment or on a group of equipments. The supported variable types are:
* <ul>
* <li>Use {@link #INJECTION_ACTIVE_POWER} to model a change on the production of a generator or on a group of generators, on
* the consumption of a load or on a group of loads or on GLSK (for Generation and Load Shift keys) that describes a
* linear combination of power injection shifts on generators and loads. The variable increase is in MW.</li>
* <li>Use {@link #INJECTION_REACTIVE_POWER} to model a change on the reactive production of a generator or on
* the reactive consumption of a load. The variable increase is in MVar.</li>
* <li>Use {@link #TRANSFORMER_PHASE} to model the change of the tap position of a phase tap changer of a two windings transformer
* or a three windings transformer that contains only one phase tap changer. The increase is in degree.</li>
* <li>Use {@link #BUS_TARGET_VOLTAGE} to model an increase of the voltage target of a generator, a static var compensator, a two
* or three windings transformer, a shunt compensator or a VSC converter station. The increase is in KV.</li>
* <li>Use {@link #HVDC_LINE_ACTIVE_POWER} to model the change of the active power set point of an HVDC line. The increase is in MW.</li>
* <li>Use {@link #TRANSFORMER_PHASE_1}, {@link #TRANSFORMER_PHASE_2} or {@link #TRANSFORMER_PHASE_3} to model the change of the tap position of a phase
* tap changer of a three windings transformer that contains several phase tap changers.</li>
* </ul>
* @author Geoffroy Jamgotchian {@literal <geoffroy.jamgotchian at rte-france.com>}
*/
public enum SensitivityVariableType {
/** increase in MW */
INJECTION_ACTIVE_POWER,
/** increase in MVar */
INJECTION_REACTIVE_POWER,
/** increase in degrees */
TRANSFORMER_PHASE,
/** increase in kV */
BUS_TARGET_VOLTAGE,
/** increase in MW */
HVDC_LINE_ACTIVE_POWER,
/** increase in degrees */
TRANSFORMER_PHASE_1(1),
/** increase in degrees */
TRANSFORMER_PHASE_2(2),
/** increase in degrees */
TRANSFORMER_PHASE_3(3);
private final Integer side;
SensitivityVariableType() {
this.side = null;
}
SensitivityVariableType(int side) {
this.side = side;
}
public OptionalInt getSide() {
return side == null ? OptionalInt.empty() : OptionalInt.of(side);
}
}