As the temperature drops and the first snowflakes start to fall, it's time to prepare your hunter sprinkler system for the harsh winter months ahead. Winterizing your sprinkler system is a crucial task that helps prevent costly repairs and prolongs the life of your system.

Neglecting to winterize your sprinkler system can lead to frozen pipes, cracked heads, and other expensive damages. This guide will walk you through the process of properly winterizing your hunter sprinkler system step by step.

Understanding the Winterization Process
The primary goal of winterizing your sprinkler system is to drain all water from the pipes and heads to prevent freezing. This process ensures that your system is ready to resume operations as soon as spring arrives.

While you can hire a professional to winterize your sprinkler system, it's a relatively simple task that can be done by homeowners with the right tools and knowledge.
Essential Tools for Winterizing

Before you begin, gather the following tools and materials to ensure a smooth winterization process:
- Adjustable wrench
- Air compressor
- Bleach (optional, but recommended)
- Compressed air"*. Yates P2272-P 5.5-Gallon 200-PSI Pancake Air Compressor" (ensure it's compatible with your system)*
- Manual drain valves
- Rice air* (for automated systems)
Preparation and Safety Measures

Before starting, turn off the water supply to your sprinkler system at the main shut-off valve, usually located near the manifold or underground pipe connector. Then, open the manual drain valves on the lowest points of your system to drain any remaining water.
If your hunter sprinkler system is automated, you'll need to shut off the controller and disconnect the battery. Always consult your system's user manual for specific instructions.
Draining the Sprinkler System

Now that your sprinkler system is prepared, it's time to drain the water from the pipes and heads. For manual systems, follow these steps:
- Manually open each zone valve, one at a time, and leave it open.
- Turn on the water supply to your sprinkler system and let it run until it trickles to a stop. This will help to drain all the water and pressure from the system.




![How To Winterize A Sprinkler System [Infographic] - Yards Improved](https://i.pinimg.com/originals/46/a8/6b/46a86bab3c1c916012df05acf3f3c933.png)

For automated systems, use the riser escutcheon* to manually open each zone valve to drain water.
Removing Water from Sprinkler Heads
Even after draining the system, water can remain in the sprinkler heads and risers. To remove this residual water, use an air compressor or a compressed air sprayer to blow air through the system.
Connect the air compressor to an ejection port on your sprinkler system's backflow preventer. Slowly increase the compressor's pressure, blowing air through the system until no water comes out of the sprinkler heads. Be cautious not to exceed the recommended pressure for your system, usually 80 psi.
Underground Noise Makers
For low elevation systems, you can use underground noise makers to help remove water and air from the system. These devices create vibrations that dislodge water from the pipe walls, allowing it to drain from the system.
Additional Steps for a Comprehensive Winterization
In addition to draining your system, consider these steps to further protect your sprinkler system from winter damage:
Adding Antifreeze
While not necessary in mild climates, adding antifreeze to your system can provide extra protection against freezing temperatures. Use a non-toxic, food-grade antifreeze made specifically for sprinkler systems. Mix the antifreeze with water in a 2.5:1 ratio and run it through the system following the same process used to drain the water.
Inspecting and Repairing Sprinkler Heads
Walk your property and inspect each sprinkler head for signs of damage. Cracks, leaks, or unexplained moisture around the heads can indicate issues that need to be addressed before winter. Replace any damaged heads and ensure that all remaining heads are properly secured to prevent movement during the freeze-thaw cycle.
Winterizing the Backflow Preventer
The backflow preventer is a critical component of your sprinkler system that prevents wastewater from flowing back into your drinking water supply. To winterize your backflow preventer, follow these steps:
- Shut off the water supply to the backflow preventer.
- Open the test cocks on both sides of the backflow preventer to drain any remaining water.
- Remove the dome cap and open the relief valve to allow any residual water to drain out.
- Reclose the relief valve and replace the dome cap.
- Close the test cocks.
It's essential to consult your backflow preventer's user manual for specific instructions, as the process may vary depending on the model.
Regular maintenance and proper winterization are vital for ensuring the longevity and optimal performance of your hunter sprinkler system. By following the steps outlined in this guide, you can protect your investment and enjoy a well-maintained sprinkler system for seasons to come. Don't forget to schedule a spring start-up service to prepare your system for the growing season and ensure all components are functioning correctly.