Garage Door Seal For Uneven Concrete
If the garage is located beneath any habitable space, the separation requirements are more stringent, necessitating the use of 5/8-inch (15.9 mm) Type X gypsum board or a material that offers equivalent protection. Because this garage is over 1,000 SF it falls outside the scope of a "private garage" and is, for code purposes, a "public garage". Section 311.3 Classifies "Parking garages, open or enclosed" as a group S-2 Occupancy.
Because the Business Occupancy is a hazard to the S-2 occupancy, a fire barrier wall must be constructed between the two. 2024 IRC R302.5.3 says "Penetrations through the separation required in Section R302.6 shall be protected as required by Section R302.11, Item 4," while 2024 IRC Table R302.6 requires separation on a wall between the dwelling unit and the garage of "Not less than 1/2-inch gypsum board or... The city is telling us that we have to have a means of egress from the space that does not require travel through the garage, per IRC Section R311.1.
To do this, they want us to build a wall across the back portion of our garage to create an enclosed hallway from a man door out the back of our garage to the stairs that lead up to the space. I have a single car garage with a sectional overhead door, I have space on one stucco wall for a 24 x 75 pedestrian door. will that size be acceptable since it is not the main egress door?
A detached garage is not going to require egress in the same manner as a habitable space. How do you egress out of a garage itself? Good question. A detached garage as i understand it wouldn't obligate a typical egress component i.e.
door EEO or similar. The leakage around a garage door and the cubic volume of a double car garage should provide an adquate supply of combustion air to any "B" vented unit. We have encouraged CO detectors in homes with attached garages for years especially if a HVAC unit is installed in the garage.
The garage is 100% residential- not a business. The first floor has lights & outlets, the second floor only has a preexisting light fixture (exterior light) from the original house and no added wiring. My attached garage has a man door, and my detached garage has a man door.
On the other hand, under the IBC an overhead garage door is allowed to be used as a required exit door for occupant loads of 10 or fewer (or maybe it's under 10 -- I don't remember). So if the IBC allows a garage door as an exit door, should the IRC be different? Does IBC specify a minimum clear height is for parking garages? If so, in what section is this found?