A Loop
The document presents a novel surgical technique called the loop-wiring method (LWT) for treating volarly displaced distal radius fractures (VD-DRFs) with small thin volar marginal fragments (VMFs), which are difficult to manage using conventional volar locking plates. The LWT involves anatomical reduction of VMFs, drilling K-wires through the fragments, and applying a soft wire for secure ...

Volarly displaced distal radius fractures (VD-DRFs) with small thin volar marginal fragments (VMFs) are challenging to treat with conventional volar locking plates (VLPs) alone. Several alternative surgical options have been reported to treat these fractures, including wire- loop fixation, spring-wire xation, hook plates, headless compression screws, and tension-band fi wiring , but the optimal ...
A Loop

Volarly displaced distal radius fractures (VD-DRFs) with small thin volar marginal fragments (VMFs) are challenging to treat with conventional volar locking plates (VLPs) alone. Several alternative surgical options have been reported to treat these fractures, including wire- loop fixation, spring-wire fixation, hook plates, headless compression screws, and tension-band wiring , but the optimal ...
We describe the technique of wire- loop fixation to treat 4 young men with a unique variant of Melone's type 4 articular fracture of the volar lunate facet, characterized by a displaced rotated ...

A Loop
The loop-wiring technique applies compressive pressure securely to the articular side of the fracture site as well as to the whole fracture site and may be advantageous in terms of secure fixation of small thin volar marginal fragments, stability of the carpus, and bone healing. Volarly displaced distal radius fractures (VD-DRFs) with small thin volar marginal fragments (VMFs) are challenging ...
The loop-wiring technique applies compressive pressure securely to the articular side of the fracture site as well as to the whole fracture site and may be advantageous in terms of secure fixation of small thin volar marginal fragments, stability of the carpus, and bone healing.

A Loop
Article " A Loop-Wiring Technique for Volarly Displaced Distal Radius Fractures With Small Thin Volar Marginal Fragments" Detailed information of the J-GLOBAL is an information service managed by the Japan Science and Technology Agency (hereinafter referred to as "JST"). It provides free access to secondary information on researchers, articles, patents, etc., in science and technology, medicine ...
Care must be taken to avoid injury to the superficial branch of the radial nerve. The first dorsal compartment is released. The tendons are retracted volarly . The fracture should be reduced and stabilized with a K-Wire placed from the distal radial styloid and aimed dorsal and proximal. Fragment specific plates should not be used in isolation.

(PDF) Wire
The displaced volar-articular fragment, however, may be relatively small; therefore, direct manipulation could lead to soft tissue stripping and osteonecrosis. We have found the technique of wire- loop fixation to be a simple, reproducible, and effective alternative method of internal fixation for these difficult fractures.






Instrument for Restoration of the Volar Tilt Preparing the instrument The 2.5 instrument for restoration of the volar tilt (A-2794) can only be used together with the correction plates 4750.11-12, A-4750.15-20) and the ADAPTIVE plates 4750.61-64, A-4750.101-112). Position the laser marking of the guide wire at the required correction angle.