Cooling demand reduction approaches for typical buildings in a future ...

The cooling demand of the building increased by employing the extreme climate condition, as a representative for future climate, with factors 3.8 and 6.4 for cooling set points 25°C and 27°C for window to floor ratio 10%. This implies the need for a resilient building to withstand future climate conditions.

The cooling demand of the building increased by employing the extreme climate condition, as a representative for future climate, with factors 3.8 and 6.4 for cooling set points 25°C and 27°C for ...
PDF Cooling Demand Reduction Approaches in a Nearly Zero Energy Building ...

Studies have been conducted to evaluate the importance of climate change and the use of future climate files on the annual energy use of buildings . Santamouris (2016) investigated the future cooling energy use of a building by implementing three scenarios based on parameters such as future climate, population increase, etc. and an average cooling demand was calculated for the future scenario.
Here, an actual engineering case study should be the one that involves the implementation of demand response control strategies for central cooling systems in commercial buildings , with the timing and context also aligning with typical operational settings.

Building Cooling Requirements under Climate Change Scenarios ...
Some mitigation strategies (e.g., thermal insulation, solar shading) showed a potential to reduce the increase in building cooling demand ; however, the reduction varied depending on the strategy and climatic zone. Further research is required to determine if existing cooling systems can handle the future increase in cooling requirements.
These factors make conventional real-time cooling dispatch strategies incompatible with actual demand . Thus, the optimization of cooling systems in office buildings presents a pertinent research domain for mitigating electricity strain and curtailing building energy consumption.

Using Cool Roofs to Reduce Heat Islands
In air-conditioned residential buildings , solar reflectance from a cool roof can reduce peak cooling demand by 11-27%. 1 Reduced air pollution and greenhouse gas emissions: By lowering energy use, cool roofs decrease the associated air pollution and greenhouse gas emissions.
Cooling floor area is growing at a higher rate than heating, driven by 1) GDP per capita growth; 2) increase in building floor area, particularly in developing economies; 3) warming climates +150% Rapid growth in cooling demand in countries with dirtier electricity grids highlights the impetus to rapidly scale up renewables across the world

Full article
Analysis showed that climate change will increase building cooling demand in all climatic zones, with the greatest increase occurring in temperate and cold climatic zones.






Reducing building energy demands can help lower energy costs. Explore the sections below to learn more about using green infrastructure to reduce building energy demands and find resources on implementation.