Understanding the 2018 IRC Girder Span Table
The 2018 International Residential Code (IRC) Girder Span Table is a crucial resource for architects, engineers, and builders, providing essential data for designing safe and efficient floor and roof systems. This table, found in Section R502.3 of the 2018 IRC, outlines the maximum allowable spans for various joist and girder sizes, helping ensure structural integrity and compliance with building codes.
Why the 2018 IRC Girder Span Table Matters
The 2018 IRC Girder Span Table is not just a list of numbers; it's a tool that promotes safety, efficiency, and consistency in residential construction. By providing clear guidelines on girder spans, it helps prevent overloading and failure of floor and roof systems, reducing the risk of structural collapse and other safety hazards. Moreover, it enables builders to optimize material usage, saving time and resources.
Key Changes in the 2018 Edition
Before delving into the table itself, it's important to note some key changes introduced in the 2018 IRC. One significant update is the inclusion of engineered wood products, such as I-joists and LVL (Laminated Veneer Lumber) girders. These materials offer enhanced strength and stiffness, allowing for longer spans compared to traditional dimensional lumber. Additionally, the 2018 IRC introduced more stringent load requirements, ensuring structures can withstand increased live loads.

Reading the 2018 IRC Girder Span Table
The 2018 IRC Girder Span Table is organized by girder size and material, with separate tables for dimensional lumber, engineered wood products, and steel joists. Each table lists the girder size, material, and maximum allowable span for various loading conditions, including dead loads (D), live loads (L), and total loads (D+L).
Example: Dimensional Lumber Girder Span Table
| Girder Size (in) | Maximum Span (ft) |
|---|---|
| 2x8 | 8 |
| 2x10 | 10 |
| 2x12 | 12 |
In this example, a 2x8 dimensional lumber girder can span up to 8 feet, while a 2x12 girder can span up to 12 feet, under the specified loading conditions.
Factors Affecting Girder Span
While the 2018 IRC Girder Span Table provides valuable guidance, it's essential to consider other factors that can affect girder span, such as:

- Loading conditions: The table assumes uniformly distributed loads. Concentrated loads, like those from heavy furniture or equipment, may require additional support.
- Slope: Girders supporting sloped floors or roofs may have reduced capacity.
- Support conditions: Girders supported at both ends have greater capacity than those cantilevered from a single support.
- Building location: Structures in areas prone to high winds, earthquakes, or snow loads may require additional reinforcement.
When to Consult an Engineer
While the 2018 IRC Girder Span Table is a helpful starting point, it's not a substitute for professional engineering services. For complex projects, unusual loading conditions, or structures with non-standard designs, it's crucial to consult a licensed structural engineer. They can provide tailored solutions, ensuring your project's structural integrity and compliance with local building codes.
More Details
ICC Digital Codes is the largest provider of model codes, custom codes and standards used worldwide to construct safe, sustainable, affordable and resilient ...

... Tables R602.7(1), R602.7(2... Texas State Residential Code Board of Plumbing Examiners 2018 > Chapter 5 Floors > Section R502 Wood Floor Framing > R502.5 ...

NOTE: R507.5 Beam plies shall be fastened with two rows of 10d nails 16” OC along each edge. Deck Beam Span Chart.

TABLE R602.7(1). GIRDER SPANS AND HEADER SPANS FOR EXTERIOR BEARING WALLS ... NJd Span NJ Span NJ Span NJ Span NJ Span NJ Span NJ Span. NJ Span NJd. 2-2 × 4. 2 ...

girder shall not exceed 1/600 of span. Provision of suitable camber to ... The positive design bending strength of composite beams has been summarized in Table I.

23.08.2023 ... Comparison of IRC 2018 and IRC 2021 codes. Expert tips for using IRC beam span tables. Deck girder span chart best practices. Open App.

28.03.2021 ... The 2021 has a footnote now to make that clear. The most important thing to know about this beam span table is it assumes every joist is ...

Where multiple span beams bear on intermediate posts, each ply must have full bearing on the post in accordance with Figures R507.5.1(1) and. R507.5.1(2). Page ...
Tables for interior and exterior wall girder and header spans were revised to reflect Southern Pine. No. 2 instead of Southern Pine No. 1 design values in IRC ...

5. See 2018 IRC for complete span table. b. Beams supporting deck joists from one side only. c. No. 2 grade, ...
... 2018 IRC beam tables grouped all species other than southern pine into a ... These are the numbers you mul- tiply the actual joist span by to deter- mine the ...

30.05.2019 ... Specific design guidance includes convenient span tables for joists and beams and charts of post sizing limitations and connection methods.

Allowable span tables are provided that greatly simplify the determination of joist, girder and sheathing sizes for raised floor systems of wood framing and ...

2018 IRC Chapter 5. 1. 2. ▫. Wood Framing and Sheathing. ▫. Span Tables ... 7(3). IRC: R502.5 Girder and Header Spans. Class Exercise #4. Joist & Girder ...

... # Posted: 30 Mar 2018 08:39pm - Edited by: ... The IRC leaves ridge beams to the engineers. As well as the strength and stiffness of the ridge beam the ...

30.01.2020 ... ▫ Review 2018 IRC ... For other grades and species and for other loading conditions, refer to the American Wood. Council for span tables -. Joists ...

04.09.2018 ... Table R507.6 Deck Beam Span Lengths. *2018 Table. TABLE R507.6. DECK BEAM SPAN LENGTHSa, b, g (ft. ‐ in.) SPECIESc. SIZEd. DECK JOIST SPAN LESS ...

... 2018 International Residential Code IRC. Knox County Code ... TABLE 4: DECK BEAM SPAN LENGTHS. WOOD. SPECIES. SIZE. DECK JOIST SPAN LESS THAN ...

Use the 2018 IRC to size deck beams and calculate beam span. By Mike Guertin ... IRC Table R50706 Deck Beam Span Lengths. The beam spans are based on ...

28.11.2021 ... ... 2018 International Building Code Book Reference Number - Table 2308.4.1.1(1) page 510 - 511 Headers Usually Are Loacted At Top Of Window or ...