Understanding 2018 IRC Span Charts: A Comprehensive Guide
The 2018 International Residential Code (IRC) introduced significant changes to span charts, which are crucial for determining the maximum allowable span of joists, rafters, and other structural members in residential construction. This guide delves into the updates, their implications, and how to effectively use the 2018 IRC span charts.
2018 IRC Span Chart Updates: What's New?
The 2018 IRC brought several updates to span charts, including new load combinations, adjusted span tables, and revised deflection criteria. These changes aim to enhance structural integrity, safety, and efficiency in residential construction.
- Load Combinations: The 2018 IRC introduced new load combinations, particularly for wind and seismic loads, which can impact the maximum allowable spans.
- Span Tables: Some span tables were adjusted, with certain members now requiring larger sizes or different species to meet the new criteria.
- Deflection Criteria: The 2018 IRC tightened deflection limits, requiring floors and roofs to deflect less than L/360 and L/240, respectively, where L is the span length.
Navigating the 2018 IRC Span Charts
To effectively use the 2018 IRC span charts, follow these steps:

- Identify the member type (e.g., joist, rafter, beam) and its material (e.g., lumber, engineered wood, steel).
- Determine the span length and the live load (LL) or dead load (DL) for the member.
- Locate the appropriate span chart for the member type and material.
- Find the intersection of the span length and load in the chart to determine the required size or species.
- Verify that the selected member meets the deflection criteria (L/360 or L/240).
Key Changes in 2018 IRC Span Charts for Common Members
Here are some notable changes in the 2018 IRC span charts for common residential members:
Floor Joists
| Span (ft) | 2015 IRC (2x10) | 2018 IRC (2x10) |
|---|---|---|
| 10 | 40 psf | 40 psf |
| 12 | 36 psf | 32 psf |
Roof Rafters
The 2018 IRC reduced the allowable spans for certain roof rafter sizes, particularly for longer spans and higher loads. For example, a 2x10 rafter with a 24 ft span now requires a #2 grade, while the 2015 IRC allowed a #3 grade.
Conclusion
The 2018 IRC span charts offer updated and more stringent criteria for determining the maximum allowable spans of structural members in residential construction. By understanding these changes and effectively using the new span charts, builders and designers can ensure the structural integrity and safety of residential structures while complying with the latest building codes.

More Details
ICC Digital Codes is the largest provider of model codes, custom codes and standards used worldwide to construct safe, sustainable, affordable and resilient ...

NOTE: R507.5 Beam plies shall be fastened with two rows of 10d nails 16” OC along each edge. Deck Beam Span Chart.

22.05.2019 ... Specific design guidance includes convenient span tables for joists and beams and charts of ... joist span lengths using IRC provisions.

Allowable span tables are provided that greatly simplify the determination of joist, girder and sheathing sizes for raised floor systems of wood framing and ...

A redundant footnote, footnote (f), was removed from IRC Table R802.5.2 ... o Deck joist span table and diagrams were revised, reflecting in part the ...

Maximum allowable spans for wood deck joists, as shown in Figure. R507.6, shall be in accordance with Table R507.6. The maximum joist spacing shall be limited ...

30.05.2019 ... This webinar introduces basic design and construction methods for single-story residential wood decks focusing on the significant changes ...

23.08.2023 ... 33') whereas this table that comes with my plans says “all spans are assuming a maximum of 24' of supported roof framing”. Can anybody help ...

DECK JOIST SPANS FOR COMMON LUMBER SPECIES (ft.-in.) Based on IRC Table R507.6. See 2018 IRC for complete span table. No. 2 grade minimum. Table 9. 14. Figure ...

The joist span tables currently in the IRC are not suitable for exterior, treated or incised lumber and there is no method for sizing beams appropriately. RB264 ...
The joist span tables currently in the IRC are not suitable for exterior, treated or incised lumber and there is no method for sizing beams appropriately. RB264 ...

The same will be true for other span tables in the code. ... Prescriptive Deck Details Design Document was not brought forward with the 2018 IRC Georgia ...
o.c. Building width = 36 ft Roof slope = 5:12. 115 MPH wind speed, Exposure B. Table R802.11 – Rafter or Truss Rafter or Truss Roof Span Roof Pitch Spacing ...

Spans for floor joists shall be in accordance with Tables R502.3.1(1) and ... Texas State Residential Code Board of Plumbing Examiners 2018 > Chapter 5 ...

16.11.2017 ... Table R-8-B. Number of openings for the Reference Houses. Reference Houses - # openings. Header. Span (ft). Reference House.

IRC 2018 International Residential Code. EFFECTIVE USE OF THE INTERNATIONAL ... span tables are provided to simplify the selection of rafter and ceiling ...
01.01.2018 ... Numerals indicated in parenthesis are applicable code sections of the 2018 International Residential Code (IRC). ... _________Allowable span [ ...

Adoption of International Residential Code® 2018 (IRC® 2018). (a) The ... The allowable span shall not exceed the values set forth in Table R703.8.3.1 ...

ICC Digital Codes is the largest provider of model codes, custom codes and standards used worldwide to construct safe, sustainable, affordable and resilient ...

13.06.2025 ... 5 - The deck beam span table is divided into several tables that provide spans ... from Appendix C of the 2018 IRC and arranged into a new table ...