Understanding 2x10 Pressure Treated Span Chart for Deck Building
When it comes to building a durable and long-lasting deck, selecting the right materials and understanding their load-bearing capacities is crucial. One of the most common lumber sizes used in deck construction is 2x10 pressure treated lumber. To ensure your deck is safe and structurally sound, it's essential to understand the 2x10 pressure treated span chart.
What is a Span Chart?
A span chart is a guide that outlines the maximum spacing between supports for a given board size and species, ensuring the board can safely support the intended load. It's crucial to follow these guidelines to prevent sagging, breaking, or even catastrophic failure of your deck.
Understanding 2x10 Pressure Treated Lumber
2x10 pressure treated lumber is a popular choice for deck framing due to its strength, durability, and resistance to rot, decay, and insect damage. The "2x10" refers to the nominal size of the board, which measures 1.5 inches by 9.25 inches when dried. The lumber is treated with preservatives to enhance its longevity and protect it from the elements.

2x10 Pressure Treated Span Chart: Key Factors
Before diving into the span chart, it's essential to understand the key factors that influence the maximum span of a 2x10 pressure treated board:
- Load: The amount of weight the board must support, including the weight of the board itself, any joists or beams it supports, and the live load (people, furniture, etc.).
- Spacing: The distance between supports, such as joists or beams. The span chart provides maximum spacing to prevent excessive deflection (bending) of the board.
- Species: The type of wood used. In this case, we're focusing on pressure treated lumber, which is typically made from southern yellow pine.
2x10 Pressure Treated Span Chart
Here's a simplified 2x10 pressure treated span chart, based on the Southern Pine Inspection Bureau's guidelines. These values assume a live load of 40 lbs/ft² (psf) and a dead load (weight of the board and any supported joists) of 10 lbs/ft². Always consult the most recent and relevant building codes and guidelines for your specific project.
| Support Spacing (on center) | Maximum Span (inches) |
|---|---|
| 12 inches | 48 inches |
| 16 inches | 42 inches |
| 20 inches | 36 inches |
| 24 inches | 30 inches |
Factors Affecting Span Chart Values
While the span chart provides a useful starting point, several factors can affect the maximum span of a 2x10 pressure treated board:

- Load: Increasing the load will reduce the maximum span. Always consider the total load, including the board's weight, any supported joists, and the live load.
- Support conditions: The type of support (e.g., bearing, simple, or cantilever) and the support's condition (e.g., level, plumb, and square) can affect the maximum span.
- Moisture content: Green (unseasoned) lumber has a higher moisture content, which can reduce its maximum span. Always use seasoned lumber for deck construction.
- Building codes: Local building codes may require additional safety factors or impose different load requirements, which can affect the maximum span.
Tips for Using the 2x10 Pressure Treated Span Chart
To ensure the safety and longevity of your deck, follow these tips when using the 2x10 pressure treated span chart:
- Always round down to the nearest whole number when calculating spans.
- Consider using smaller, more frequent supports to reduce deflection and improve the overall appearance of your deck.
- Consult local building codes and guidelines to ensure your deck design complies with all relevant regulations.
- Work with a licensed professional if you're unsure about any aspect of your deck design or construction.
By understanding and following the 2x10 pressure treated span chart, you can build a strong, safe, and durable deck that will provide years of enjoyment. Always prioritize safety and consult relevant resources to ensure your deck is structurally sound.
More Details
Tables 1 through 3 are abbreviated span tables for pressure-treated Southern Pine visual grades No. ... 2 x 10. (1.5 x 9.25). 2 x 12. (1.5 x 11.25). 2 x 6. (1.5 ...

Pressure treated lumber span charts designed for outdoor deck construction. These charts cover 2x4, 2x6, 2x8, 2x10, and 2x12 treated lumber sizes.

Lumber span tables are valuable guides which provide the maximum allowable spans for different types and sizes of Southern Pine and pressure-treated lumber.

Southern Pine # 2, Pressure Treated: MAXIMUM SPAN FOR ONE STORY. 2 (2" X 6"). 5'-0". 3 (2" X 6"). 6'-0". 2 (2" X 8"). 6'-4". 3 (2' x 8"). 8'-0". 2 (2" X 10").

16.04.2025 ... Refer to the span chart below, and double check with your local building official about the specific building code requirements in your area. In ...

2x10, 16′2″, 14′0″, 11′5″. 2x12, 18′0″, 16′6″, 13′6″. Douglas Fir Larchd. Hem Fir ... Beam Span Charts. Pressure Treated Beam Span Charts. Data collected from IRC ...

The only real alternative to pressure-treated lumber for deck builders. Introducing the most boundary-breaking Laminated. Veneer Lumber on the market. PWT ...

03.04.2024 ... NP stands for Not Permitted. I'd suggest going with the IRC tables. Cantilever length can't be more than 25% of the joist span so the longer the ...

2 x 10. 1½ x 9¼. 13'- 4". 12'- 0". 10'- 0". 2 x 12. 1½ x 11¼. 15'- 10". 14'- 0". 11'- 7". Pressure Treated. No. 2 Hem-fir (incised). 2 x 8. 1½ x 7¼. 10'- 5". 9 ...

In this ar- ticle, I'll focus on how to read the new maximum deck beam span tables in the. 2021 IRC, and explain how to use the code's new “joist span factors” ...

2x8. 2x10. 2x12. 2x6. 2x8. 2x10. 2x12. Maximum floor joist spans. JOIST. SPACING. (inches). SPECIES AND GRADE. (ft. - in.) (ft. - in.) (ft. - in.) (ft. - in.) ( ...

... pressure treated S.P.F. guard posts. • Minimum guard height: 35" for decks < 5'•11" above grade. 42" for decks > 5'•11" above grade. THE ONTARIO BUILDING CODE ...

17.07.2020 ... Depending on the species and grade, 2-2x10's can span 12' with pressure treated lumber without incising and 10'-6” with incising.

01.07.2023 ... Naturally durable or pressure treated timber should be specified where necessary to meet the requirements of the application service class ...

... stress in bending (Fb), tension parallel-to-grain. (Ft), horizontal shear (Fv) ... 2 x 10. 2 x 12. Species spacing on center or Group. Grade. 12". 16". 19.2 ...

All other wood not in contact with the ground shall be approved pressure treated, or naturally durable wood, such as; Redwood, Cedar, or other approved material ...

For two 2x10 pressure-treated boards with 1/2" plywood sandwiched between, maximum span depends on load type and spacing. Typically, a floor joist span chart ...

Southern Yellow Pine, for example, has a higher strength-to-weight ratio than Eastern White Pine, meaning it can span longer distances. Typical Span Tables for ...

Non-Incised Pressure Treated Lumber – wood product treated with a preservative using a pressure process. ... Span Tables 9.23.4.2.-H to 9.23.4.2.-K ...

Using the beam span table, select your beam lumber size. Where it intersects ... 6.5” Min for 2 X 10. 7.5” Min for 2 X 12. *distance is permitted to be ...