Understanding 4x4 Beam Span Tables for Structural Design
The 4x4 beam span table is an essential tool for structural engineers, architects, and builders, providing a quick and reliable method to determine the maximum allowable live load for a simply supported 4x4 beam. This table is based on the American Institute of Steel Construction (AISC) 36th Edition and considers the beam's span, material, and section properties.
What is a 4x4 Beam?
A 4x4 beam, also known as a 4-inch by 4-inch beam, is a structural steel beam with a nominal depth of 4 inches and a width of 4 inches. Despite its name, the actual dimensions are slightly larger due to the inclusion of the beam's fillets. The most common 4x4 beam sections are W4x9, W4x14, and W4x19, which have varying depths, widths, and weights per foot.
How to Read a 4x4 Beam Span Table
To use a 4x4 beam span table effectively, you must understand its layout. Typically, the table will have the following columns:

- Beam Section (e.g., W4x9, W4x14, W4x19)
- Depth (in inches)
- Weight per Foot (in pounds per foot)
- Span (in feet)
- Maximum Allowable Live Load (in pounds per foot)
The maximum allowable live load is determined by the beam's section, span, and the applicable load combination. The table provides conservative estimates, ensuring the beam's strength and stability under various loading conditions.
Factors Affecting 4x4 Beam Span Table Values
Several factors influence the maximum allowable live load values in a 4x4 beam span table:
- Beam Section: Different beam sections have varying strengths and stiffnesses, affecting their load-carrying capacities.
- Span: Longer spans require stronger beams to resist bending moments and deflections.
- Material Properties: The yield strength and modulus of elasticity of the steel affect the beam's performance.
- Load Combination: The table considers various load combinations, such as dead load plus live load, to account for different loading scenarios.
Using the 4x4 Beam Span Table in Practice
To use the 4x4 beam span table in practice, follow these steps:

- Identify the beam section and span.
- Locate the corresponding row in the table.
- Determine the maximum allowable live load for the given beam section and span.
- Compare the calculated live load with the applied live load to ensure the beam's safety.
- Consider additional factors, such as beam spacing, load sharing, and support conditions, to refine your design.
Example: Designing a Simply Supported 4x4 Beam
Let's design a simply supported 4x4 beam with a span of 10 feet and an applied live load of 40 psf (pounds per square foot).
| Beam Section | Depth (in) | Weight per Foot (lb/ft) | Span (ft) | Max Allowable Live Load (psf) |
|---|---|---|---|---|
| W4x9 | 8.96 | 2.25 | 10 | 50 |
| W4x14 | 14.07 | 3.60 | 10 | 75 |
| W4x19 | 18.97 | 5.00 | 10 | 100 |
From the table, we can see that a W4x9 beam has a maximum allowable live load of 50 psf, which is sufficient for our applied live load of 40 psf. Therefore, a W4x9 beam is suitable for this application.
In conclusion, understanding and effectively using a 4x4 beam span table is crucial for designing safe and efficient steel structures. By considering the table's layout, influencing factors, and following the design steps, engineers can make informed decisions and create reliable structures.
More Details
18.12.2021 ... A 4x4 header spans 3' -6" if bearing weight, and 4'-0" in non bearing. No waver will protect you. Just the fact that you wrote it up, is ...

The span table below indicates allowable spans for various open beam framing members ... 4x4. 4x6. 4x8. 4x10. 24. 32. 48. 24. 32. 48. 24. 32. 48. 24. 32. 48. 9'-3 ...

03.01.2005 ... Dimensional Lumber Deck Beam Span Chart ; Southern Pine · 3-2X12, 15'-0" ; Douglas Fir-Larch,. Hem-Fir,. Spruce-Pine-Fir,. Redwood,. Cedars,.

09.04.2019 ... These calculators were for different types of woods and 2x sizes "sistered" (sp). There was nothing on true 4x4's that I found. I could not find ...

Size matters: 4x4 beams can usually only support spans up to 6–8 feet. Weight adds up: If you're adding a roof—especially a heavy one made of wood, metal, or ...

19.10.2004 ... I can't find a span table than mentions a 4″ x 4″ beam. Owing to ... I would build it with a 2X10; however, the combination of the 2X6 and 4X4 ...

4X4. 4X4. 4X4. 4X4. 4X4. 4X4. 4X4. 4X6. 10. 2X6. 2X6. 2X6. 6. 4X4. 4X4. 4X6. 4X6. 4X6. 4X6 ... BEAM TABLE IS BASED ON. VALUES FOR DOUGLAS. FIR/LARCH #2 OR BETTER.

The beam tables provide the allowable uniform load in pounds per linear foot for Douglas fir-Larch beams of varying spans from 6 to 15 feet and sizes from 2x6 ...

vor 8 Tagen ... Enter lumber size, type of use, and span requirements in the Design Criteria section. Calculator generates the maximum span distance as well ...

Beam Span (ft). 4x6. 4x8. 4x10. 4x12. 4x14. 6x6. 6x8. 6x10. 4x6. 4x8. 4x10. 4x12. 4x14 ... 1 Douglar Fir-Larch Column Capacity (lbs.) Column Length (ft). 4x4.

SFPA provides size selection tables for various beam spans and loading combinations for Southern Pine dimension lumber and glulam.

20.04.2024 ... 4x4s are Fence posts, not Deck supports and a double 2x8 is just weak by design. It may carry the loads on the chart but you can expect a lot of deflection and ...

Douglas fir is one of the most popular types of lumber in North America, valued for its strength, versatility, and relative affordability.

13.02.2021 ... A 4x4 typically cannot span 10 feet unsupported due to limited load capacity and deflection risk. For a 10-foot table, consider using larger ...

BEAM SIZE. Up to 4'-0". 4X4. 4'-1" to 6'-0". 4X6. 6'-1" to 8'-0". 4X8. 8'-1" to 10 ... Maximum span of tributary load 20'-0". RAFTER SIZE. SPACING. ALLOWABLE ...

Our floor joist span tables are based on loadings given in the newer, amended version of BS 6399-1. This means that some values are slightly more conservative.

HEADER SPAN & SIZE: SEE TABLE “B”. CLEARANCE: 6' - 8" MIN. 8' - 0" MAX ... 4x4 Posts min. 4X4 POST. 1" STANDOFF BETWEEN. CONCRETE AND WOOD. POST. COLUMN BASE ...

25.11.2019 ... I'm hoping to use 4x4 (nominal) wood beams as living room floor joists, but none of the online span tables/calculators seem to handle 4x lumber.

8' - 0" MAX. RAFTER SPAN & SIZE SEE TABLE "A". EXISTING WOOD. STUD WALL. ROOF ... *4x4 BRACES FOR H.F.Z. KNEE BRACING REQUIRED WHEN. RAFTER SPAN EXCEEDS 12 ...

02.06.1993 ... The TS 4x4 weighs less. USE TS 4x4x0.1875" dia ... For the 12'-0" floor span and 12.2 foot beam span: From the table on page 12 a 3" dia.
