Understanding BC Building Code Beam Span Tables
The BC Building Code, also known as the National Building Code of Canada, provides a comprehensive set of guidelines for the design and construction of buildings in British Columbia. One of the key aspects covered in the code is the sizing and spacing of structural elements, including beams. The code provides tables to help determine the maximum span of beams based on their material and loading conditions.
Why Use Beam Span Tables?
Beam span tables are a quick and efficient way to size beams for common loading conditions. They are based on extensive calculations and testing, ensuring that beams designed using these tables will meet the strength and serviceability requirements of the BC Building Code. Using these tables can save time and ensure compliance with the code.
How to Read Beam Span Tables
Beam span tables typically display the maximum allowable span for a given beam depth, material, and loading condition. The tables are organized with beam depth on the y-axis and span on the x-axis. The loading conditions are usually indicated by different tables or colors. Here's a simple example:
| Span (ft) | Depth (in) | Loading Condition 1 | Loading Condition 2 |
|---|---|---|---|
| 10 | 12 | 12 | 10 |
| 12 | 14 | 14 | 12 |
| 14 | 16 | 16 | 14 |
In this example, a beam with a depth of 12 inches can span 10 feet under Loading Condition 1, but only 12 feet under Loading Condition 2.
Factors Affecting Beam Span
Several factors can affect the maximum span of a beam, including:
- Material: The strength and stiffness of the beam material (e.g., steel, wood, concrete) significantly impact its maximum span.
- Loading Condition: The type and magnitude of loads on the beam can affect its span. The BC Building Code defines several loading conditions, including dead loads (the weight of the beam and any permanent fixtures) and live loads (temporary loads like people or furniture).
- Beam Depth: Deeper beams are stronger and can span further than shallower beams of the same material.
- Support Conditions: The way a beam is supported at its ends and intermediate points can affect its maximum span.
When to Use Beam Span Tables and When to Calculate
Beam span tables are designed for common loading conditions and beam depths. If your beam doesn't fit these criteria, you'll need to perform a detailed calculation to determine its maximum span. Always consult the BC Building Code for specific requirements and exceptions.

Conclusion
Understanding and correctly using beam span tables in the BC Building Code can save time and ensure compliance with the code. Always remember that these tables are a guide and may not cover all scenarios. When in doubt, consult a professional engineer or perform a detailed calculation.
More Details
Span Tables. British Columbia Building Code 2018. Division B. Span Tables. Table 9.20.17.4.-A. Maximum Allowable Clear Spans for Lintels in Flat Loadbearing ...
Beam and lintel spans are calculated based on a maximum supported length of 4.9 m. Spans may be increased by 5% for supported lengths of not more than 4.3 m, by ...

12.05.2025 ... ... beam and joists sizes using the British Columbia Building Code (BCBC). Note: The BCBC span tables are essentially the same as the National ...

22.04.2026 ... You most likely need a steel beam, architect or engineer should be able to look it up easily enough. ... You can find the Span Tables at the end, ...

(joists and beams) can usually be selected from span tables in the Code. ... * BC Building Code is freely available at all public libraries in British Columbia.

24.11.2023 ... and Appendix C of Division B of the. 2018 Code. 3. Page 5. Table of ... Span Book. A-9.23.4.2. CWC. 2014. Engineering Guide for Wood Frame.

BC Calc® performs engineering analysis to help our customers size beams, joists, columns, studs and tall walls for their building projects. It is simple to use, ...

20.02.2025 ... Council's span tables. Question – can an Engineer grade a timber ... Loads within the BC Building Code are expressed in. kN or kN/m (kilo ...

VERSA-LAM® One Floor Beam Span Tables . . . . . . . . . . . . . . . . 5 ... Refer to the building code evaluation report or the. BC CALC® software.

Table 5a – Beam Selection Incised Supporting Single Span (m). 11. Table 5b ... Reference should always be made to the appropriate Building. Code and/or standard.

18.07.2012 ... Associate Committee on the National Building Code. Access condition. For questions about Code licensing, sales, technical support, to obtain ...

09.12.2020 ... See also Figure 5. BEAM SPANS. (SPANS TAKEN BETWEEN SUPPORTING POSTS) ... The Building Code requires stair width to be at least 900 ...

Locate a span that meets or exceeds the required beam span, ... addition to complying with the deflection limits of the applicable building code, other deflection ...

Readily available tables in residential building codes provide maximum allowable ... Answers to Self-Test for BC Building Code Divisions A, B, C - Part 1.

This new edition of The Span Book includes added tables for deck joists and beams, more lintel options, and recalculates all spans using revised shear ...

vor 8 Tagen ... PLIB believes the information generated by this calculator is accurate and conforms with design standards referenced by U.S. building codes.

27.10.2024 ... ... BC BUILDING CODE-PART 9 SINGLE FAMILY DWELLING BUILDINGS Module 23 Section 9.23 ... span of the beam according to the Notes to Table (1) .

The floor load design for this type of building can be found in Part 4, Table [Link]. ... Span Tables provided in Part 9. Part 9 is limited in scope and only ...

29.04.2025 ... Parowan Timber Beam. https://awc ...

The span tables for wood roof trusses have been calculated for the Associate Committee on the National Building Code by the Division of Building Research of the ...