Understanding Beam Spans in Ontario's Building Code
The Ontario Building Code (OBC) plays a crucial role in ensuring the safety and structural integrity of buildings across the province. One of its key aspects is the regulation of beam spans, which significantly impacts the design and construction process. This article delves into the intricacies of beam spans as per the Ontario Building Code, providing a comprehensive guide for architects, engineers, and builders.
What are Beam Spans?
In structural engineering, a beam span refers to the horizontal distance between two supports, such as walls, columns, or other structural elements that bear the load of the beam. Understanding beam spans is vital as they directly influence the size and strength of beams, as well as the overall structural design of a building.
Ontario Building Code Requirements for Beam Spans
The OBC provides clear guidelines for beam spans, with the primary objective of ensuring the safety and stability of structures. These requirements are outlined in Division B of the code, specifically in Section 4.1.2.2, "Beam Spans".

Maximum Beam Spans
The OBC stipulates maximum beam spans based on the type of construction and the loading conditions. For instance, in light-frame construction, the maximum unbraced beam span is 6.0 m (20 ft) for floors and 4.5 m (15 ft) for roofs. For heavy timber construction, these spans can extend up to 9.0 m (30 ft) and 6.0 m (20 ft) respectively.
Beam Spans and Loads
The OBC also considers the live loads that beams are designed to support. For example, in residential occupancies, the live load for floors is 1.9 kN/m² (40 lb/ft²), while for roofs, it's 0.9 kN/m² (20 lb/ft²). These loads, along with the beam span, determine the size and strength of the beam required.
Factors Affecting Beam Spans
Several factors can influence the allowable beam spans in Ontario buildings. These include:

- Type of construction (e.g., light-frame, heavy timber, masonry)
- Loading conditions (live loads, dead loads, snow loads)
- Beam spacing and orientation
- Presence of continuous or cantilever beams
- Building height and configuration
Design Considerations for Beam Spans
When designing beam spans, it's essential to consider the following:
- Compliance with OBC requirements
- Economy and efficiency in beam size and material usage
- Structural integrity and stability under various loading conditions
- Fire resistance and sound transmission requirements
Table: Maximum Beam Spans as per OBC
| Type of Construction | Maximum Unbraced Beam Span (m) |
|---|---|
| Light-frame | 6.0 (floors), 4.5 (roofs) |
| Heavy timber | 9.0 (floors), 6.0 (roofs) |
| Masonry | 4.5 (floors), 3.0 (roofs) |
It's crucial to note that the table above provides a simplified overview. The actual maximum beam spans can vary based on the specific design and loading conditions of a building.
Conclusion
Understanding and adhering to the Ontario Building Code's requirements for beam spans is paramount for architects, engineers, and builders. By doing so, they ensure the safety, stability, and longevity of buildings in Ontario. This article has provided a detailed overview of beam spans in the context of the OBC, equipping readers with the knowledge necessary to navigate these requirements effectively.
More Details
The enclosed tables, regulations and schedules are copies of various sections of the 2024 Ontario. Building Code. ... (1) Beam spans apply only where the ...

2024 Ontario Building Code | Maximun Span Tables Beams Built Up Wood Beams Steel Beams Joists Ceiling Joists Floor Joists Roof Joists Lintels Notching & ...

The spans for wood joists and rafters shall conform to the spans shown in Tables A-1 to A-7 for the uniform live loads shown in the Tables.

Ontario Building Code span tables A1 & A-8 from Division B Part 9 are provided for floor joists and beams within a building. These tables do not account for ...

11.12.2023 ... Let's learn the difference between Floor Joists and Ceiling Joists [9.23 of the Ontario Building Code, 9.23.4.2.(1), Tables A-1, Table A-2, ...

09.04.2026 ... Factual claims in this post were verified by Konstruction Group against primary regulatory sources including the Ontario Building Code (O. Reg.

... beam. • Max " joist ... IT IS THE CONTRACTOR'S RESPONSIBILITY TO. ENSURE THAT ALL CONSTRUCTION CONFOMS. TO THE REQUIREMENTS OF THE ONTARIO. BUILDING CODE.

09.10.2024 ... The supported length (half of the sum of the joist lengths) is 3.95m. The span of the open space the beam is to support is 17ft. The beam would ...

Get instant Ontario Building Code answers with Part/Section/Article references. 2026 OBC hub for Part 9 residential, Part 7 plumbing, energy codes & PDFs.

of the National Building Code - 2023 Alberta Edition (NBC(AE)) references the span tables ... Ottawa, Ontario K1P 6B9. Phone Number: (613) 747-5544. Fax ...

2.2.) 4) Spans for roof ridge beams shall conform to the spans in Span Table 9.23.4.2.-L for the uniform ...

5/31/2020 The Ontario Building Code | Deflections · 1. Roof rafters, roof joists and roof beams No ceiling 1/180 · 2. ceiling joists Other than plaster or gypsum ...

(1) The spans for steel beams with laterally supported top flanges shall conform to Table 9.23.4.3. for floors and Tables A-20 to A-29 for roofs and floors.

27.06.2023 ... This is a clip from the full On-Demand Course, Building Codes for Building Decks, Down the Load Path, available exclusively at ...

19.10.2024 ... Just wondered if any of you can shed some light on the steel beam tables provided in Part 9 of the Ontario Building Code. I'll take a simple ...

18.07.2012 ... National Research Council Canada. Associate Committee on the National Building Code.

Maximum deflection limits are set by building codes. They are expressed as a fraction; clear span in inches (L) over a given number. For example: a floor joist ...
30.04.2025 ... In this article, we will focus specifically on LVL beam span tables for Ontario, Canada, under the current 2012 version of the Ontario Building ...

... spans more than two suites of residential occupancy or more than two patients' or residents' sleeping rooms in a Group B, Division 2 or 3 occupancy, and the ...

Use these simple calculators to size Trus Joist TimberStrand LSL and Parallam PSL beams and headers. Select the application below you are looking to calculate.