Understanding LVL Beam Span Tables in Australia: A Comprehensive Guide
When it comes to construction and engineering projects in Australia, understanding the correct beam span and loading is crucial for structural integrity and safety. This is where LVL (Laminated Veneer Lumber) beam span tables come into play. These tables provide essential data to ensure your beams are fit for purpose and comply with Australian standards.
What are LVL Beam Span Tables?
LVL beam span tables are a set of data that outline the maximum span lengths for LVL beams under various loading conditions. They are designed to help engineers, architects, and builders select the appropriate beam size for their project. The tables typically display span lengths for different beam depths and loading scenarios, such as uniformly distributed load (UDL) and concentrated load.
Why Use LVL Beam Span Tables?
Using LVL beam span tables offers several benefits:

- Ensures compliance with Australian standards (AS 1720.1 - 2010 and AS 1720.2 - 2010)
- Promotes safety and structural integrity
- Saves time and resources by reducing the need for complex calculations
- Enables quick and easy selection of appropriate beam sizes
Understanding LVL Beam Span Tables: Key Factors
Before diving into the tables, it's essential to understand the key factors that influence beam selection:
- Span Length: The distance between supports
- Beam Depth: The height of the beam
- Loading: The weight or force applied to the beam (UDL or concentrated load)
- Grade of LVL: The strength and stiffness of the LVL
Where to Find LVL Beam Span Tables in Australia
LVL beam span tables are typically provided by LVL manufacturers and can be found on their websites. Some popular LVL suppliers in Australia include:
- Hyne Timber
- Stirling Timber Products
- Lysaght
- Boral
How to Read and Use LVL Beam Span Tables
LVL beam span tables usually present data in a table format, with columns for beam depth, loading, and maximum span length. Here's an example of how to read and use the tables:
| Beam Depth (mm) | Loading (kN/m) | Maximum Span Length (mm) |
|---|---|---|
| 200 | 1.0 | 4500 |
| 200 | 1.5 | 3000 |
| 300 | 1.0 | 6500 |
In this example, a 200mm deep LVL beam can span up to 4500mm under a uniformly distributed load of 1.0 kN/m. However, if the loading increases to 1.5 kN/m, the maximum span length reduces to 3000mm. A 300mm deep beam can span up to 6500mm under the same 1.0 kN/m loading.
Tips for Using LVL Beam Span Tables
To ensure accurate and safe beam selection, consider the following tips:
- Always use the latest tables and standards
- Consider additional loads, such as imposed loads and wind loads
- Account for any beam cantilevers or overhangs
- Consult with a structural engineer if unsure
In conclusion, LVL beam span tables are an invaluable resource for selecting appropriate LVL beams in Australian construction projects. By understanding and using these tables correctly, engineers, architects, and builders can ensure structural safety, compliance with standards, and efficient project delivery.
More Details
Span. For the purpose of using these tables, span may be interpreted as the clear distance between supports measured along the beam. Single Span Beams are beams ...

This Design Guide and Load Tables assist in the selection of. SmartLVL® 14 beams for most of the common structural arrange- ments met in domestic construction.
LVL span tables are technical charts that specify the maximum distance (span) a Laminated. Veneer Lumber (LVL) beam can safely cover between supports, based on ...

Table 2: Continuous Span. Table 1: Single Span. Important: These Span Tables only apply to Metrix Timber LVL products. LVL Manufacturing: AS/NZS 4357.0.

CHH Woodproducts Australia also has a range of composite plywood LVL I-Joists ... Strutting Beams. Supporting Underpurlins and Ceiling Joists#/Hanging Beams#.

e-beam is the premier laminated veneer lumber (LVL) product available in. Australia. LVL has many advantages over traditional building products, including its ...

For beams that are continuous over two unequal spans, the design span. & resultant span description, depend on the percentage span differences between the two ...

Table A8-6: Unit-Load Deflection Span Tables for a Simply Supported Box Beam with a Uniformly ... LINTEL BEAM TO BE 3.6 M SPAN, 300 X 45 mm BBF BRAND LVL.

... Span Tables. Index of span tables. 10. Scope of this publication. This Design Guide and Load Tables assist in the selection of. SmartLVL® 14-15 beams for most ...

This table displays Formply Australia E12 joints supporting concrete formwork, with a deflection criterion of Class III (span/270). 225. 300. 400. 450. 480. 600.

Laminated Veneer Lumber (LVL) is an engineered wood material with defined and reliable ... Table 2: Purlin Span Guidance. Product. Span i-Beams. (LVL flanged i- ...

This value tells you the longest distance that specific LVL beam can safely span ... We have developed a quick guide on reading the Dindas LVL Span Tables. To ...
e-beam is the premier laminated veneer lumber (LVL) product available in Australia and has many advantages over traditional building products.

Span tables for Kerto. LVL beams, panels and studs are presented on Metsä Wood web site. The tables help designers to work faster and more efficiently. For more.

TecBeam · SmartFloor · SmartForm · Form Ply · SmartEdge · SmartPlank · FrameSmart · H2S ... LVL Span Tables. Downloads -. Smart10 LVL Design Guide 2024, 8.19 MB ...

Australia. These Span Tables have been prepared in accordance with standard engineering principles, the relevant test reports and. Australian standards, ie ...

17.12.2019 ... This document provides an overview of resources available from Dindas Australia including span tables, design guides, installation guides, ...

03.10.2016 ... The joint strength group for Nelson Pine LVL depends on the orientation and type of fasteners as in Table 3. ... The two span tables below define ...

Scarf Cuts are permitted for Kerto LVL beams as specified in the table. ... KERTO LVL PRODUCT MANUAL 17. Page 18. SPAN TABLES. 18 KERTO LVL PRODUCT MANUAL. Page ...

formwork LVL beams in Australia. A high wax loading in the moisture ... Values of load or deflection may not be interpolated for spans intermediate to those ...
