LVL (Laminated Veneer Lumber) beams are a popular choice in construction due to their strength, stability, and aesthetic appeal. When designing structures that incorporate LVL beams, it's crucial to understand how to read and apply LVL beam span tables. This guide will walk you through the intricacies of LVL beam span tables, ensuring you can make informed decisions for your construction projects.
What are LVL Beam Span Tables?
LVL beam span tables are resources that outline the safe spans for LVL beams based on their size, load, and support conditions. These tables are typically provided by the manufacturer and are essential for determining the maximum distance between supports for a given beam without exceeding its load-carrying capacity.
Why Use LVL Beam Span Tables?
- Safety: Following the recommended spans ensures the beams can safely support the intended loads without deflecting excessively or failing.
- Efficiency: Using the correct span saves material and reduces costs by avoiding over-engineering.
- Compliance: Adhering to the manufacturer's recommendations helps ensure your project meets building codes and standards.
How to Read LVL Beam Span Tables
LVL beam span tables typically present data in a grid format, with columns for beam size, support conditions, and live loads. Here's a breakdown of how to read these tables:

| Beam Size (Depth x Width) | Support Conditions | Live Load (psf) | Maximum Span (inches) |
|---|---|---|---|
| 2x6 | Simple Span | 40 | 8-1/2 |
| 2x6 | Continuous Span | 40 | 12-1/2 |
| 2x8 | Simple Span | 40 | 10-1/2 |
In this example, a 2x6 LVL beam with simple support can safely span 8-1/2 inches when subjected to a live load of 40 pounds per square foot (psf). The same beam with continuous support can span 12-1/2 inches under the same load conditions.
Factors Affecting LVL Beam Span
Several factors influence the safe span of LVL beams, including:
- Beam size: Larger beams can span further than smaller ones.
- Support conditions: Continuous spans allow beams to span further than simple or cantilevered spans.
- Load: Heavier loads require shorter spans.
- Grade and species: Different LVL grades and species have varying strengths.
- Deflection criteria: Building codes may impose limits on beam deflection to prevent excessive movement.
When to Consult an Engineer
While LVL beam span tables provide a starting point, it's essential to consult a licensed engineer for complex or critical applications. Engineers can perform detailed calculations, account for unique loading conditions, and ensure your project meets all relevant codes and standards.

In conclusion, understanding and correctly applying LVL beam span tables is vital for designing safe, efficient, and code-compliant structures. By familiarizing yourself with these tables and considering the factors that affect beam span, you can make informed decisions that enhance your construction projects.
More Details
Span. For the purpose of using these tables, span may be interpreted as the clear distance between supports measured along the beam. Single Span Beams are beams ...

Basic information. Laminated Veneer Lumber (LVL) made from spruce. ... 1. Tables are for simple span beams (no cantilever) and uniformly distributed loads.

installed edgewise as a single-span beam) the STEICO LVL R lintel is designed. The table shows the maximum clear opening and the required bearing length.

FLOOR BEAM SPAN TABLES (feet). Loads (lb/feet2). Tributary width. (feet) ... 5- TABLES ASSUME SINGLE LVL BEAM SPANS;. 6- CLEAR SPAN IS MEASURED CENTRE-TO ...

Floor Beam Span Tables (One Storey) . ... over the VERSA-LAM® LVL beam, multiply the tributary width by 1.25 and always select the value closer.

This Design Guide and Load Tables assist in the selection of. SmartLVL® 14 beams for most of the common structural arrange- ments met in domestic construction.

For the purpose of using the following tables, span may be interpreted as the clear distance between supports measured along the beam. Single Span Beams are ...

Roof must have positive slope to prevent ponding. • Tables will accomodate beam slopes to a maximum of. 2:12. Span (ft) Condition 5 ...
To use these charts: 1. Select the correct table for the beam application you need. 2. Choose the required beam span in the left column.

* Indicates Total Load value controls. 2.0E Microllam® LVL: Floor—100% (PLF). How to Use This Table. 1.

Wesbeam e-beam Span Tables. Roof Members. Rafters. 4. Roof Beams. 6. Strutting ... The spans listed in this brochure for e-beam LVL manufactured by Wesbeam apply.

Roof must have positive slope to prevent ponding. • Tables will accomodate beam slopes to a maximum of. 2:12. Span (ft) Condition 5 ...

To use these charts: 1. Select the correct table for the beam application you need. 2. Choose the required beam span in the left column.

They are stronger yet lighter than steel beams. Span tables provide the maximum spans of e-splay beams for different sizes, roofing types, and roof areas ...

Tables are for simple span beams (with a support at each end) and uniformly distributed loads. 2. Continuous lateral restraint must be provided at the top ( ...

Where floor joists are continuous over the beam, this table applies only when the 'A' span is ... LVL Beam. Width. 1¾". 3½". 1¾". 3½". 1¾". 3½". 1¾". 3½".

* Can be applied to the Max-Lam™ LVL beam in addition to its own weight. Simple or multiple Max-Lam™ LVL beam spans. Key to Table: LL- Maximum live load ...

For beams that are continuous over two unequal spans, the design span. & resultant span description, depend on the percentage span differences between the two ...

Output files (PDF) can be created in each of these languages ... Span table: LVL S – single span beam. Char. permanent load gk. 1,0. kN/m². 1,5.

LVL span tables are technical charts that specify the maximum distance (span) a Laminated. Veneer Lumber (LVL) beam can safely cover between supports, based on ...