The Ontario Building Code (OBC) is a critical resource for anyone involved in the construction industry in the province. It sets out the minimum requirements for the design, construction, and safety of buildings. One of the key components of the OBC is the beam table, which provides essential guidance on the design and sizing of beams. This article aims to provide a comprehensive, yet easy-to-understand guide to the Ontario Building Code beam table.
Why the Beam Table Matters
The beam table in the OBC is a vital tool for engineers, architects, and builders. It simplifies the process of designing beams that meet the code's strength and stiffness requirements. By using the beam table, designers can ensure that their beams will safely support the loads they are expected to bear, contributing to the overall safety and longevity of the structure.
How the Beam Table Works
The Ontario Building Code beam table is organized by beam depth and span, providing allowable loads for various beam configurations. It covers a range of beam depths from 8 inches to 36 inches, and spans from 6 feet to 24 feet. The table accounts for different beam materials, including wood, steel, and concrete.

Key Factors in Beam Design
- Beam Depth: The depth of a beam refers to its height, or the distance from the top of the beam to the bottom. Deeper beams can typically support more load than shallower ones.
- Beam Span: The span of a beam is the distance between its supports. Longer spans require stronger beams to prevent excessive deflection.
- Material: The strength and stiffness of the beam material significantly impact its performance. The OBC beam table accounts for different materials by providing separate tables for each.
Using the Beam Table: A Step-by-Step Guide
To use the Ontario Building Code beam table, follow these steps:
- Determine the beam's span and depth based on your design requirements.
- Identify the beam material you plan to use.
- Locate the appropriate table in the OBC that corresponds to your beam's material and dimensions.
- Find the intersection of your beam's depth and span in the table. The allowable load for that beam configuration will be listed.
- Compare the allowable load to the actual load your beam will bear. If the allowable load is greater than the actual load, your beam design meets the OBC requirements.
When to Consult a Professional
While the Ontario Building Code beam table is a powerful tool, it's essential to remember that it's not a substitute for professional expertise. If you're unsure about any aspect of beam design or have complex design requirements, it's always best to consult with a qualified engineer or architect.
Staying Up-to-Date with Changes to the OBC
The Ontario Building Code is periodically updated to reflect changes in building practices, materials, and safety standards. It's crucial to use the most recent version of the OBC when designing beams. You can find the latest version on the Ontario government's official website.

Conclusion
The Ontario Building Code beam table is an invaluable resource for anyone designing or building structures in Ontario. By understanding and using the beam table effectively, you can ensure that your beams meet the OBC's stringent requirements, contributing to the safety and longevity of your structures. Always remember that while the beam table is a powerful tool, it's just one part of the comprehensive approach to safe and sustainable building that the OBC promotes.
More Details
... tables, regulations and schedules are copies of various sections of the 2024 Ontario. Building Code. ... beam. 82. 2 per joist. Joist to joist splice (See also ...

(1) Except as required in Sentence (2) and Article 9.23.13.10., the spans for wood joists and rafters shall conform to the spans shown in Tables A-1 to A-7 for ...

2024 Ontario Building Code | Maximun Span Tables Beams Built Up Wood Beams Steel Beams Joists Ceiling Joists Floor Joists Roof Joists Lintels Notching & ...

09.04.2026 ... Factual claims in this post were verified by Konstruction Group against primary regulatory sources including the Ontario Building Code (O. Reg.

... beam. • Max " joist ... IT IS THE CONTRACTOR'S RESPONSIBILITY TO. ENSURE THAT ALL CONSTRUCTION CONFOMS. TO THE REQUIREMENTS OF THE ONTARIO. BUILDING CODE.

19.10.2024 ... I am in the US and am not familiar with those tables. That said, deflection is a serviceability issue – not a strength limit state.

25.09.2025 ... BUILT-UP BEAMS, made of dimensional wood lumber have been ... certain conditions. These tables are OBC TABLES A8-A11. A carpenter must be able to ...

2.2.) 4) Spans for roof ridge beams shall conform to the spans in Span Table 9.23.4.2.-L for the uniform ...

meets requirements of the Ontario Building Code; this will be at the discretion of your local building ... REQUIREMENTS TABLE ON PG. 5A. NOTE: FOR ALL ...

(1) The spans for steel beams with laterally supported top flanges shall conform to Table 9.23.4.3. for floors and Tables A-20 to A-29 for roofs and floors.

09.10.2024 ... This specifies "Maximum Spans for Built-up Floor Beams Supporting not more than One Floor" and my question is where is the table for beams only supporting the ...

Ontario Building Code span tables A1 & A-8 from Division B Part 9 are provided for floor joists and beams within a building. These tables do not account for ...

25.01.2024 ... Span tables provide information about the maximum allowable spans for beams used in construction projects in the province.

The definition of “House” has been removed. New rules for ceiling heights and 5/8″ Type X fire separation are now standard for multiplexes. ⚡ Energy Efficiency.

11.12.2023 ... Let's learn the difference between Floor Joists and Ceiling Joists [9.23 of the Ontario Building Code, 9.23.4.2.(1), Tables A-1, Table A-2, ...

2006 BUILDING CODE FOR HOUSING. Table A-1 (Cont'd). Maximum Spans for Floor ... (5) for alternatives to strapping. 236. Ontario.

18.07.2012 ... National Research Council Canada. Associate Committee on the National Building Code. 'Span Tables for Wood Joists, Rafters, Trusses and Beams: ...

5/31/2020 The Ontario Building Code | Deflections · 1. Roof rafters, roof joists and roof beams No ceiling 1/180 · 2. ceiling joists Other than plaster or gypsum ...

(1) The objectives of this Code shall be those set out in Table 2.2.1.1 ... Beams. Table 11.5.1.1.A. Table 11.5.1.1.B. Table 11.5.1.1.C. Table 11.5.1.1 ...

9.23.4.3-J · 2024 ontario building code spand table part 9. Maximum Spans for Steel Beams Supporting a Roof and one Floor in Dwelling Units Where Beams ...