Understanding Treated Glulam Span Charts: A Comprehensive Guide
Treated glulam, a engineered wood product, is renowned for its strength, durability, and aesthetic appeal. When designing structures with treated glulam, understanding the span capabilities is crucial. This guide delves into treated glulam span charts, their importance, and how to interpret them.
Why Use Treated Glulam?
Treated glulam offers numerous benefits, including resistance to rot, decay, and insect damage, thanks to its preservative treatment. This makes it an ideal choice for outdoor structures and harsh environments. Moreover, its strength-to-weight ratio allows for longer, unsupported spans compared to solid sawn lumber.
What is a Span Chart?
A span chart is a design tool that outlines the maximum allowable spans for joists, beams, and other structural members based on their size and loading conditions. It ensures that the structural member can support the intended load without excessive deflection or failure.

Interpreting Treated Glulam Span Charts
Treated glulam span charts typically present data in a tabular format, with columns for member size (depth and width), loading conditions (dead load, live load, snow load, etc.), and maximum allowable span. Here's a simplified example:
| Member Size (inches) | Loading Condition (psf) | Maximum Allowable Span (feet) |
|---|---|---|
| 4x6 | 30 | 8 |
| 4x8 | 30 | 10 |
| 6x8 | 30 | 14 |
In this chart, a 4x6 treated glulam beam can span up to 8 feet under a loading condition of 30 psf. A larger beam, like a 6x8, can span up to 14 feet under the same loading condition.
Factors Affecting Treated Glulam Span
Several factors influence the maximum allowable span of treated glulam members:

- Member Size: Larger members can span longer distances.
- Loading Conditions: Heavier loads require shorter spans.
- Grade of Treated Glulam: Higher grades offer greater strength and longer spans.
- Support Conditions: Continuous supports allow longer spans than simple or cantilever supports.
Using Span Charts in Design
To use a treated glulam span chart in design, follow these steps:
- Determine the loading conditions for the member.
- Identify the available member sizes.
- Locate the intersection of loading condition and member size in the span chart.
- Ensure the proposed span does not exceed the maximum allowable span.
- Consider other design factors, such as support conditions and grade of treated glulam.
Always consult with a structural engineer for complex or critical designs to ensure safety and compliance with building codes.
Conclusion
Treated glulam span charts are invaluable tools for designers and builders working with treated glulam. By understanding how to interpret and apply these charts, you can ensure the structural integrity and longevity of your treated glulam structures. Always remember, the key to successful design is a balance of strength, durability, and aesthetics.
More Details
... Glulam Floor Beams - 100% Floor Load. Span (ft). Span Type. Glulam Depth (in.) 6. 8. 10. 12. 14. 16. 18. 34. 36. 38. 40. 22. 24. 26. 28. 30. 32. March 28, 2013.

These conditions necessitate the use of the Table 2 capacity chart. Due to ... (2) Span = simply supported beam. (3) Maximum deflection = L/180 under ...

A 5 1/4" x 5 1/2" treated glulam column up to 14' will support all glulam beams in Tables 1 and 2 for simple span applications. Anthony Forest. Span Calculator.

Treated in accordance with EN BS351-1:2007 and EN335. Tolerances. +/- ... Glulam quality GL28c. Loading: Dead load + live load (domesƟc acc. to EN1990 ...

The span tables and details in this brochure for glue laminated beams (Glulam) have been designed in accordance with sound and widely accepted engineering ...
Allowable moment shall be multipled by (21/Span Length [ft])1/10 for longer spans. Page 3. 3. Boise Cascade EWP • BOISE GLULAM® IJC Guide • 01/ ...

They can span long distances and carry virtually any design load. The Glulam Ridge Beam Application Tables are designed to provide the smallest glulam beam ...

All exterior timber needs to be protected from termites, by treatment or well-planned detailing to avoid any damage of the timber. Page 7. FLOOR JOISTS ...

Design properties: Table 1 lists the allowable design properties for Rosboro Treated Glulam 24F-V4/DF and. 24F-V8/DF. The allowable spans for Rosboro Treated ...

All timber treatment is to comply with NZS 3640:2003 and AS/NZS1604.5:2002. To mitigate long-term beam deflection for beams spanning over. 3m, a mid-span ...

Visual and Glulam Grades. The Southern Forest Products Association provides ... Treated · Southern Pine Decks · Raised Floor Living · How to Use · Span Tables ...

continuously over the beam, these tables require that both spans are equal on either side of the beam. ... glulam beams are supplied with zero camber which makes ...

Table 23 Guidance on the choice of surface treatment for interior glulam ... span tables, quantities, volumes, surface areas and angles. Download the ...

and hardwood glulam beams available. ... The span to use in the case of unequal continuous spans is the "resultant span description " as shown in the table above.

Access Unalam's glulam technical resources, including span tables, design values, and engineering specifications for structural and architectural laminated ...

Longitudinal glulam deck section and span charts for multilane bridges (on this and all similar figures, fasteners and asphalt wearing surface were omitted for ...

FINGER JOINTED LAMINATED TREATED SUSTAINABLE WARRANTED. Niagara Sales and Distribution, 145 Alford Forest Road, PO Box 332, Ashburton 7740, New Zealand p: +64 3 ...

A V8 glulam can be designed for multiple-span conditions and canti levers ... Please note that when glulam beams are treated and installed in exterior ...

27.02.2026 ... Glulam Span Tables were developed primarily for domestic applications in accordance with NZ and Australian Standards.

A chart of glulam strength grades for varying load conditions. Need help calculating the size or weight? Ask one of our engineers.