Understanding Treated LVL Beam Span Charts
In the realm of construction and engineering, the selection of the right beam for a given span is a critical decision. Treated Laminated Veneer Lumber (LVL) beams have gained significant traction due to their strength, durability, and dimensional stability. To aid in this selection process, treated LVL beam span charts have been developed. This article delves into the intricacies of these charts, their importance, and how to use them effectively.
What are Treated LVL Beam Span Charts?
Treated LVL beam span charts are comprehensive guides that outline the safe and efficient use of treated LVL beams. They provide a clear breakdown of beam sizes, their respective spans, and the loads they can safely bear. These charts are typically provided by the manufacturers and are based on rigorous testing and calculations that adhere to established engineering standards.
Why are Treated LVL Beam Span Charts Important?
Treated LVL beam span charts serve several crucial purposes:

- Safety: They ensure that beams are not overloaded, preventing structural failures and potential accidents.
- Efficiency: By selecting the right beam for the span, these charts help optimize material usage and reduce costs.
- Compliance: They help ensure that structures comply with relevant building codes and standards.
How to Read Treated LVL Beam Span Charts
Treated LVL beam span charts typically present information in a tabular format. Here's a breakdown of how to read them:
| Beam Size (width x depth) | Span (center-to-center) | Uniformly Distributed Load (UDL) per ft |
|---|---|---|
| 2x6 | 6 ft | 40 psf |
| 2x8 | 8 ft | 60 psf |
| 2x10 | 10 ft | 80 psf |
The chart above shows that a 2x6 treated LVL beam can safely span 6 feet and bear a uniformly distributed load of 40 pounds per square foot (psf). Similarly, a 2x8 beam can span 8 feet and bear 60 psf, and so on.
Factors Affecting Beam Selection
While treated LVL beam span charts provide a solid starting point, several factors can influence beam selection:

- Load Type: The type of load (uniformly distributed, concentrated, etc.) can affect the beam's performance.
- Span Length: Longer spans may require larger beams or additional support.
- Support Conditions: The type of support (simple, continuous, etc.) can impact the beam's capacity.
- Building Codes: Local building codes may have specific requirements that must be met.
When to Consult an Engineer
While treated LVL beam span charts are invaluable tools, they should not replace professional judgment. If you're unsure about a beam selection, it's always best to consult with a qualified structural engineer. They can provide tailored advice based on the specific requirements of your project.
More Details
5. Joist tables are based upon 100% duration of load. 6. Spans based on hanger on ledger side and 3" bearing on LVL beam.

4 Beams require support across their full width. 5 Conditions outside the scope of this guide may be designed using CSD Software. 6 Shaded cells controlled by ...

Span. For the purpose of using these tables, span may be interpreted as the clear distance between supports measured along the beam. Single Span Beams are beams ...
Beam Span Table. DRY USE — MAXIMUM ALLOWABLE DECK BEAM SPANS SUPPORTING ... installation required by code and required in the PWT Treated™ LVL Installation Guide.

The spans for Pressure Treated Dimension Lumber are provided as a reference only. ... These spans are from the PWT Treated LVL Tech Guide. All procedures and ...

23.03.2026 ... LVL (Laminated Veneer Lumber) beams offer predictable, consistent performance across spans that traditional timber cannot match. This guide ...

... LVL beam. For bearing on other wood materials, the bearing resistance of ... The tabulated values are for simple span or for continuous span beams. 4 ...

Versa-Lam® laminated veneer lumber (LVL) beams and headers eliminate twisting, shrinking and splitting, and deliver flatter, quieter floors and structures.

Use these simple calculators to size Trus Joist TimberStrand LSL, Parallam PSL and Microllam LVL beams and headers and Treated Parallam Plus PSL deck beams and ...

Product description: PWT™ preservative-treated laminated veneer lumber (LVL), designated as PWT TREATED ... The deflection equation for a simple-span beam under ...

Information about Treated LVL Framing Lumber is from Pacific Wood Tech and for beam spans for double-1.5″ material references this spans chart. Treated LVL ...

LVL span tables are technical charts that specify the maximum distance (span) a Laminated Veneer Lumber (LVL) beam can safely cover between supports, ...

mm wide LVL beam would reduce the beam capacity at that sec- tion by ... Maximum recommended Ridge or Intermediate roof beam span - Single span (mm). 2 ...

... Beam 15c - Span Tables - Deck , Floor , Lintels · Treated Pine Deck Joist Span Tables · HYSPAN LVL Span Tables Engineered Wood - Available H2-s treated or H3 ...

Joist Span Charts ; JOIST SPECIES, JOIST SIZE · MAXIMUM DECK JOIST SPAN LENGTH (feet-inches) ; PWT Treated LVL, 1 – 2×6, 11′1″ ; PWT Treated LVL · 1 – 2×8, 14′10″ ...

19.03.2024 ... What are the experiences with using pressure-treated LVL beams for large span deck construction? Tony Dudek ▻ Deck Construction Tips and Tricks.

PRIOR TO PRESERVATIVE OR FIRE-RETARDANT TREATMENT. UNAUTHORIZED ... 5- TABLES ASSUME SINGLE LVL BEAM SPANS;. 6- CLEAR SPAN IS MEASURED CENTRE-TO ...

e-beam span tables can be downloaded here. Read More. View as PDF.

Full imposed loading is applied to all spans in the multi-span roof beam table. The multispan beam tables are based on multiple equal spans. In determining the ...

2024 Span Tables. Span Tables. Softwood Lumber – North EPD. EPD ...