VLM Run // SW 2023-14 · City of Tampa, Stormwater Engineering · issued 2025-05-21

Woodmere & Lois Avenue drainage set

Nine sheets, read end to end. Every annotation, table, structure and surveyed symbol on the set, extracted and placed. Every value on this page points back at the exact spot on the drawing it was read from: hover any row and the sheet zooms to it.

Sheets
936 x 24 in, issued for construction
Text lines
5,376each with its place on the sheet
Symbols located
28220 legend classes
Viewports
42titled drawings
Symbols with callouts
87%30 carry a confirmed ID
Structure IDs
4822 on 2+ sheets

Per sheet

Click a row to open that sheet.

#TitleDiscipline Text linesSymbolsViewports
1COVER SHEETcover27002
2WOODMERE & LOIS AVENUE DRAINAGE IMPROVEMENTS – LEGEND, PROJECT MAP AND EX. INV…general5712010
3WOODMERE & LOIS AVENUE DRAINAGE IMPROVEMENTS NOTES SHEETgeneral57603
4WOODMERE & LOIS AVENUE DRAINAGE IMPROVEMENTS - PLAN AND PROFILEcivil1,122443
5WOODMERE & LOIS AVENUE DRAINAGE IMPROVEMENTS — PLAN AND PROFILEcivil1,205873
6WOODMERE & LOIS AVENUE CROSS-SECTIONS PLAN SHEETcivil18703
7WOODMERE & LOIS AVENUE CROSS-SECTIONS PLAN SHEETcivil17203
8WOODMERE & LOIS DRAINAGE IMPROVEMENTS — PAVEMENT RESTORATION PLAN AND DETAILcivil9501316
9TREE PROTECTION & SILT FENCE SHEETdetail32309

Symbols across the set

Names come from the symbol legend on sheet 2, not from a list written by hand, so the same reading transfers to any set that prints its own legend. Counts are as found.

Legend classTotalSheets
iron pipe532, 4, 5, 8
water meter472, 4, 5, 8
water valve cover392, 4, 5, 8
shared utility pole382, 4, 5, 8
drainage manhole222, 4, 5, 8
telephone pedestal192, 4, 5, 8
reclaimed water valve cover152, 4, 5, 8
single support sign112, 4, 5, 8
sanitary manhole82, 4, 5, 8
post82, 4, 5, 8
fire hydrant72, 5, 8
iron rod32, 5, 8
gas regulator22, 5
cleanout22, 8
telephone manhole22, 8
light pole22, 4
pedestrian signal12
mailbox12
concrete monument12
nail and disk12

Cross-sheet structure index

Every structure callout found anywhere in the set, and the sheets it appears on. Assembled from the drawings themselves, with no manual list. 22 of 48 identifiers appear on more than one sheet, which is the surface where a survey value and a design value can disagree without anyone noticing. Click a row to open the first sheet it appears on.

IDKind SheetsMentions
ST-1Proposed structure4, 64
ST-2Proposed structure42
ST-3Proposed structure4, 64
ST-4Proposed structure4, 64
ST-5Proposed structure4, 64
ST-6Proposed structure42
ST-7Proposed structure4, 64
ST-8Proposed structure53
ST-9Proposed structure53
ST-10Proposed structure53
ST-11Proposed structure53
ST-12Proposed structure53
ST-13Proposed structure53
ST-14Proposed structure5, 73
ST-15Proposed structure5, 74
D-17Existing drainage2, 53
D-18Existing drainage2, 53
D-19Existing drainage21
D-20Existing drainage2, 52
D-21Existing drainage2, 82
D-22Existing drainage2, 52
D-23Existing drainage2, 52
S-4Existing sanitary21
S-5Existing sanitary2, 42
S-6Existing sanitary21
S-7Existing sanitary2, 52
S-8Existing sanitary2, 52
S-16Existing sanitary41
V-1Water valve21
V-2Water valve21
V-3Water valve21
V-4Water valve21
V-5Water valve21
V-6Water valve21
V-7Water valve2, 42
V-8Water valve2, 42
V-9Water valve21
V-10Water valve21
V-11Water valve2, 52
V-12Water valve21
V-13Water valve21
V-14Water valve2, 52
V-15Water valve2, 52
V-16Water valve2, 53
V-1033Water valve51
SL-1Section line41
SL-2Section line41
SL-4Section line51

The same feature, read twice

Sheet 2 tabulates the existing structures and valves with their stations. Sheet 5 draws them. Locating a symbol on sheet 5, reading the callout printed beside it, and then looking that identifier up in the sheet 2 table is a check where neither side sees the other: one number comes from pixel geometry, the other from a printed table read as text. Ten identifiers came back this way, and none is more than three quarters of a foot apart.

IDSymbol located on sheet 5 Station measured thereStation tabulated on sheet 2Delta
V-15water valve cover28+57.3828+57.400.02 ft
V-14water valve cover28+45.5128+45.580.07 ft
D-23drainage manhole28+18.0928+17.840.25 ft
S-8sanitary manhole28+25.5928+25.950.36 ft
D-17drainage manhole27+59.5527+59.170.38 ft
D-18drainage manhole27+38.3227+38.740.42 ft
D-22drainage manhole28+18.0928+18.550.46 ft
S-7sanitary manhole28+25.3828+25.860.48 ft
V-11water valve cover27+53.2127+53.850.64 ft
V-16water valve cover28+52.2528+53.010.76 ft

This is the reconciliation in miniature. Four more identifiers (D-21, S-5, V-7, V-8) were recovered the same way on sheets 4 and 8, but those sheets cover different station ranges at different scales and have not had their alignments fitted, so their positions are not yet comparable. The identification held; only the positional check is outstanding.

How every number was checked

A reading is only worth something if it can be held against a value it never saw. Two independent checks were run on this set.

CheckRead from the drawing Printed elsewhere in the setWhere that value is printedDelta
ST-10 stormwater manhole, station24+54.2 24+54Sheet 5 structure schedule 0.20 ft
S-6 sanitary manhole, station24+96.3 24+96.14Sheet 2 sanitary structures table 0.16 ft
Legend block read as its own test set20 of 20 20Symbol legend, sheet 2 0 missed

Position. Structures are reported by station and offset, not by pixel. The alignment was fitted from the printed station labels alone, then tested against two structures whose stations are tabulated elsewhere in the set, so neither check could see the value it was being measured against. Both landed within a quarter of a foot.

Recall. The symbol legend on sheet 2 is a labelled test set that ships inside the drawing: every glyph is printed beside its own name. Reading sheet 2 with no special handling returned all 20 point-symbol classes, each correctly named and in the right row. The four remaining legend entries are line witness marks rather than point devices, and are correctly excluded rather than missed.

How to read this

Sheet
1 of 9 cover
Text lines
270 each located on the sheet
Symbols
0 0 classes
Viewports
2 titled drawings found

COVER SHEET

This is the cover sheet of the construction set for the Woodmere & Lois Avenue Drainage Improvements project, Mobility Department, Stormwater Engineering Division, City of Tampa (Contract No. 25-C-00041, project no. SW 2023-14). It does not specify construction details itself but orients the contractor to the project by showing the project location on a City of Tampa map and providing an index of the nine sheets in the set. The named project alignment is S. Lois Avenue from W. Dale Ave. to W. Azeele St.

Viewports

TitleKindScaleContents
Project / Location Maplocation mapnoneLine map of the City of Tampa showing the road grid, Tampa City Limits, adjacent Pasco and Hillsborough County lines, the Hillsborough River, Old Tampa Bay, MacDill Air Force Base, and Tampa International Airport. A thick black arrow with a circled area at the south end (around the Dale Ave. / Lois Ave. intersection) is labeled 'PROJECT LOCATION S. LOIS AVENUE W. DALE AVE. TO W. AZEELE ST.' A north arrow is shown at the upper left.
INDEXtable / schedule blocknoneTwo-column table of 'SHEET No.' and 'DESCRIPTION' listing sheets 1–9: (1) COVER SHEET w/ INDEX, (2) PROJECT MAP, LEGEND, CONTROL POINTS & EX. INVERTS, (3) NOTES, (4) PLAN AND PROFILE SHEET, (5) PLAN AND PROFILE SHEET, (6) CROSS-SECTIONS, (7) CROSS-SECTIONS, (8) INTERSECTION REPAVING PLAN & DETAILS, (9) TREE PROTECTION EROSION CONTROL PLANS & SILT FENCE DETAIL.

Quantities this sheet can support

None for construction takeoff; this cover sheet carries no measurable quantities (no pipe lengths, structure counts, etc.). The only counts present are the set size (9 sheets) and the index list of sheet numbers 1–9.

Key notes read from the sheet

  • Top-right project number: 'SW 2023-14'.
  • Project location callout: 'PROJECT LOCATION — S. LOIS AVENUE — W. DALE AVE. TO W. AZEELE ST.'
  • Title block: 'PLANS FOR WOODMERE & LOIS AVENUE DRAINAGE IMPROVEMENTS', Mobility Department, Stormwater Engineering Division, City of Tampa.
  • Contract No. 25-C-00041.
  • Title block stamp: 'Yuan Li, P.E. #66595, CHIEF ENGINEER'; date 05/21/25; DES: SEB; DRN: ZB; CKD: JDM.
  • Sheet number block: 'COVER SHEET', SHEET 1 OF 9.
  • Plot date (left margin): 'Wednesday, May 21, 2025'.

Every line on the sheet is typed by what it is: a structure callout, a station, an invert value, a utility witness tag, a proposed or existing note. That is what makes an annotation addressable rather than merely readable. Hover a row to light every instance of that type on the sheet.

Annotation typeCountExample
Note or long string6TREE PROTECTION EROSION CONTROL PLANS & SILT FENCE DETAIL
Other lettering264MACDILL AIR FORCE BASE

Surveyed symbols found on this sheet, named by the set's own legend. Hover a class to light every instance at once. Counts are reported as found, never adjusted to match an expectation.

Legend classCount
None detected on this sheet.

Every instance, with the callouts printed beside it

Each located symbol, and the text on the sheet within reach of it, nearest first. Distances are real feet at the sheet scale, not pixels. Where a callout carries an identifier that names this kind of feature, it is promoted to ID; proximity alone does not establish labelling, agreement does. Hover a row to zoom to that symbol.

SymbolStationIDCallouts within reach
None.

270 lines read from this sheet, including rotated title block lettering. The 400 longest are listed here. Hover a row to zoom to it on the sheet.

TextConfidenceType
TREE PROTECTION EROSION CONTROL PLANS & SILT FENCE DETAIL0.996Note or long string
PROJECT MAP, LEGEND, CONTROL POINTS & EX. INVERTS0.989Note or long string
INTERSECTION REPAVING PLAN & DETAILS1.0Note or long string
Stormwater Engineering Division1.0Note or long string
Stormwater Engineering Division1.0Note or long string
W. DALE AVE. TO W. AZEELE ST.0.983Note or long string
MACDILL AIR FORCE BASE0.996Other lettering
WOODMERE & LOIS AVENUE0.998Other lettering
PLAN AND PROFILE SHEET1.0Other lettering
PLAN AND PROFILE SHEET0.968Other lettering
DRAINAGE IMPROVEMENTS1.0Other lettering
COVER SHEET w/ INDEX1.0Other lettering
Yuan Li, P.E. #665950.999Other lettering
HILLSBOROUGH COUNTY0.999Other lettering
Mobility Department1.0Other lettering
Mobility Department0.998Other lettering
TAMPA CITY LIMITS0.983Other lettering
TAMPA CITY LIMITS0.992Other lettering
HOWARD-FRANKLAND1.0Other lettering
IN TERNA TIONAL0.951Other lettering
S. LOIS AVENUE0.978Other lettering
INTERNA TIONAL0.977Other lettering
CROSS-SECTIONS1.0Other lettering
CROSS-SECTIONS1.0Other lettering
DATE: 05/21/250.999Other lettering
CHIEF ENGINEER1.0Other lettering
OLD TAMPA BAY0.998Other lettering
Stormwater Er1.0Other lettering
CITY of TAMPA0.987Other lettering
PASCO COUNTY0.999Other lettering
HILLSBOROUGH1.0Other lettering
HILLSBOROUGH1.0Other lettering
SAN JOSE ST.0.995Other lettering
BLOOMINGDALE1.0Other lettering
HILLSBOROUGH0.964Other lettering
Contract No.1.0Other lettering
DOWNS BLVD.1.0Other lettering
CITY LIMITS0.965Other lettering
DESCRIPTION1.0Other lettering
COVER SHEET0.966Other lettering
SW 2023-140.973Other lettering
ot 1 11 250.779Other lettering
25-C-000411.0Other lettering
MAGDALENE1.0Other lettering
LINEBAUGH1.0Other lettering
ISENHOWER0.893Other lettering
CROSSTOWN1.0Other lettering
EVERETTST1.0Other lettering
PLANS FOR1.0Other lettering
SHEET No.1.0Other lettering
REVISIONS1.0Other lettering
REVISIONS0.998Other lettering
/ER SHEET1.0Other lettering
ITV MPA0.772Other lettering
FLETCHER1.0Other lettering
LOCATION1.0Other lettering
MASCOTTE1.0Other lettering
COLUMBUS0.995Other lettering
CAUSEWAY1.0Other lettering
MAHATNAN0.806Other lettering
BAYSHORE0.934Other lettering
INTERBAY1.0Other lettering
WOODMERI0.957Other lettering
ott 250.624Other lettering
HILUNTY0.813Other lettering
FLORIDA1.0Other lettering
SKIPPER1.0Other lettering
TERRACE1.0Other lettering
OULVARD0.859Other lettering
PROJECT1.0Other lettering
FLORIDA0.755Other lettering
AIRPORT1.0Other lettering
KENNEDY1.0Other lettering
ANHATAN0.727Other lettering
MACDILL0.989Other lettering
BAY AVE0.943Other lettering
BRIDGE1.0Other lettering
BEARSS1.0Other lettering
MORRIS1.0Other lettering
FOWLER1.0Other lettering
CARROL1.0Other lettering
TEMPLE1.0Other lettering
WATERS1.0Other lettering
SPRUCE1.0Other lettering
BRIDGE1.0Other lettering
EUCLID1.0Other lettering
MACILL0.885Other lettering
BRIDGE1.0Other lettering
BRUCE1.0Other lettering
RIVER1.0Other lettering
TAMPA1.0Other lettering
VENUE0.971Other lettering
BLVD.1.0Other lettering
BUSCH1.0Other lettering
OUARD0.843Other lettering
SLIGH1.0Other lettering
BLVD.0.961Other lettering
TAMPA1.0Other lettering
LOIDA0.783Other lettering
TAMPA1.0Other lettering
M. L.0.997Other lettering
BLVD.1.0Other lettering
RMNIA0.682Other lettering
HIMES0.971Other lettering
FRANK1.0Other lettering
ADAMO1.0Other lettering
BLVD.0.999Other lettering
SWANN1.0Other lettering
BLVD.1.0Other lettering
HWMY.0.708Other lettering
BLVD.1.0Other lettering
BLVD.0.995Other lettering
BLVD.1.0Other lettering
BLVD.1.0Other lettering
SHORE0.986Other lettering
GANDY1.0Other lettering
BLVD.1.0Other lettering
INDEX1.0Other lettering
NOTES1.0Other lettering
SHEET1.0Other lettering
LAKE1.0Other lettering
AVE.1.0Other lettering
CITY0.901Other lettering
GUNN1.0Other lettering
LAKE1.0Other lettering
HWY.1.0Other lettering
3OTH0.907Other lettering
AVE.1.0Other lettering
HWY.0.832Other lettering
AVE.1.0Other lettering
AVE.1.0Other lettering
DALE0.856Other lettering
4OTH0.773Other lettering
40TH0.914Other lettering
AVE.1.0Other lettering
4 220.518Other lettering
SEER0.786Other lettering
AVE.0.827Other lettering
JULY1.0Other lettering
34TH0.905Other lettering
KING1.0Other lettering
ESKA0.719Other lettering
ORTH0.817Other lettering
AVE.1.0Other lettering
26TH1.0Other lettering
15TH0.929Other lettering
AVE.0.895Other lettering
AVE.1.0Other lettering
AVE.0.852Other lettering
5OTH0.907Other lettering
H00H0.537Other lettering
BRY`0.723Other lettering
GAND1.0Other lettering
DALE0.982Other lettering
WEST0.938Other lettering
DATE1.0Other lettering
DATE1.0Other lettering
DES:1.0Other lettering
DRN:1.0Other lettering
CKD:1.0Other lettering
Stol0.831Other lettering
2751.0Other lettering
RD.1.0Other lettering
5971.0Other lettering
5811.0Other lettering
3011.0Other lettering
RD.1.0Other lettering
SI.0.655Other lettering
ST.0.84Other lettering
AVE1.0Other lettering
ST.0.751Other lettering
6851.0Other lettering
RD.1.0Other lettering
ARY0.88Other lettering
MAB0.868Other lettering
2751.0Other lettering
ST.0.987Other lettering
VE.0.927Other lettering
ZED1.0Other lettering
EKA0.726Other lettering
ST.0.77Other lettering
VE.0.738Other lettering
2ND0.97Other lettering
VE.0.663Other lettering
8R10.558Other lettering
ST.0.84Other lettering
ST.0.746Other lettering
DR.1.0Other lettering
OME0.962Other lettering
2751.0Other lettering
3011.0Other lettering
HWY0.892Other lettering
5070.87Other lettering
1050.714Other lettering
AVE1.0Other lettering
ARY0.72Other lettering
ARE0.861Other lettering
BAY1.0Other lettering
ST.1.0Other lettering
0250.971Other lettering
Vo.0.945Other lettering
No.1.0Other lettering
No.1.0Other lettering
SEB1.0Other lettering
JDM1.0Other lettering
411.0Other lettering
B.0.79Other lettering
OF0.998Other lettering
ST0.969Other lettering
ST0.848Other lettering
411.0Other lettering
810.689Other lettering
560.969Other lettering
411.0Other lettering
921.0Other lettering
921.0Other lettering
411.0Other lettering
921.0Other lettering
601.0Other lettering
DR1.0Other lettering
BR1.0Other lettering
411.0Other lettering
IS0.887Other lettering
601.0Other lettering
601.0Other lettering
BR1.0Other lettering
411.0Other lettering
601.0Other lettering
411.0Other lettering
921.0Other lettering
921.0Other lettering
751.0Other lettering
411.0Other lettering
BB1.0Other lettering
OF1.0Other lettering
A0.665Other lettering
A0.84Other lettering
T0.599Other lettering
N0.867Other lettering
O0.86Other lettering
V0.832Other lettering
10.839Other lettering
口0.775Other lettering
20.678Other lettering
81.0Other lettering
41.0Other lettering
41.0Other lettering
C0.675Other lettering
50.872Other lettering
11.0Other lettering
21.0Other lettering
00.999Other lettering
31.0Other lettering
41.0Other lettering
51.0Other lettering
60.989Other lettering
71.0Other lettering
81.0Other lettering
60.988Other lettering
90.997Other lettering
90.998Other lettering
61.0Other lettering
31.0Other lettering
11.0Other lettering
51.0Other lettering
21.0Other lettering
41.0Other lettering
10.999Other lettering
91.0Other lettering
60.952Other lettering

The sheet as continuous text, in the order a person would read it. Note columns become prose, printed tables stay tables.

CITY of TAMPA

Mobility Department Stormwater Engineering Division

PLANS FOR WOODMERE & LOIS AVENUE DRAINAGE IMPROVEMENTS

Contract No. 25-C-00041

Yuan Li, P.E. #66595 CHIEF ENGINEER

No.DATEREVISIONS
3
2
1
No.DATEREVISIONS
6
5
4

DES: SEB DRN: BB CKD: JDM DATE: 05/21/25

CITY of TAMPA Mobility Department Stormwater Engineering Division

COVER SHEET

SHEET 1 OF 9

Every printed table on this sheet, recovered as rows and cells.

Revision block

No.DATEREVISIONSNo.DATEREVISIONSDE
36DR
25CK
Sheet
2 of 9 general
Text lines
571 each located on the sheet
Symbols
20 20 classes
Viewports
10 titled drawings found

WOODMERE & LOIS AVENUE DRAINAGE IMPROVEMENTS – LEGEND, PROJECT MAP AND EX. INVERTS

This is a legend and reference sheet for the Woodmere & Lois Avenue drainage improvements. It provides the line, symbol, abbreviation, and hatching legends used throughout the set, plus a not‑to‑scale project location map showing existing and proposed stormwater pipes, inlets, and manholes. It also tabulates existing conditions that a contractor must verify in the field: control points, the horizontal alignment, water valves, and the invert/top elevations of existing drainage and sanitary structures.

Viewports

TitleKindScaleContents
LEGENDlegend block (line/symbol legend)noneLine-type key: 'UP TO 18" & SMALLER' vs '24" & LARGER' pipe sizes; Sanitary Sewer Gravity Line, Drainage Pipe, Electrical Cable Or Duct, Telephone Cable Or Duct, Tree Protection Zone, Fence, Overhang/awning/Canopy, Overhead Lines, Bank Line, Reclaimed Water, Water.
ABBREVIATION LEGENDtable/legend blocknoneTwo-column list of abbreviations (A=Arc Length, CLF=Chainlink Fence, CONC.=Concrete, ELEV=Elevation, ERCP=Elliptical RCP, GPS, HDPE, INV=Invert, LB, LS, NGS, PSM, PVC, PVCF, RCP=Reinforced Concrete Pipe, VCP=Vitrified Clay Pipe, BFOC=Buried Fiber Optic Cable).
SYMBOL LEGENDlegend block (utility/structure symbols)noneGraphic symbols for Concrete Monument, Fire Hydrant, Gas Regulator, Guy Wire, Iron Pipe, Iron Rod, Licensed Business, Light Pole, Manhole - Drainage, Manhole - Sanitary, Meter - Water, Nail and Disk, Shared Utility Pole, Single Support Sign, Witness-Telephone, Pedestrian Signal, Telephone Pedestal, Mailbox, Post, Cleanout, Valve Cover-Reclaimed Water, Valve Cover-Water, Witness-Gas, Witness-Fiber Optic.
HATCHING LEGENDlegend blocknoneHatch patterns for 'Concrete' and 'Tac Mat'.
CONTROL POINTStablenoneRows 101–113 with Point, Station, Offset, Alignment (SRL1/SRL2), Northing, Easting, Elev, and Description (e.g. 'Set 1/2" Iron Rod GFY', 'Set Nail & Disk GFY').
ALIGNMENTtablenoneHorizontal alignment for W. DALE AVE (SRL1) and S. LOIS AVE (SRL2): Station, Northing, Easting, Bearing (S 89°19'55" E / N 00°48'12" E), and Distance (1000.00' each).
WATER VALVEStablenoneEntries V-1 through V-16 with NAME, STA, OFF, ALIGNMENT (SRL1/SRL2), TYPE (POTABLE/RECLAIMED), and RIM/NUT dimensions.
EX. DRAINAGE STRUCTURESschedule blocknoneExisting drainage manholes/curb inlets D-17 through D-23 with station, offset, top elevation, throat elevation, and individual pipe inverts (e.g. 30" ERCP, 18" RCP, 15" RCP).
EX. SANITARY STRUCTURESschedule blocknoneExisting sanitary manholes S-4 through S-8 with station, offset, top elevation, and 8" VCP inverts; several flagged 'PIPES NOT VERIFIED DUE TO EXCESSIVE TRAFFIC'.
PROJECT LOCATION MAPlocation map (plan)NOT TO SCALEStreet grid (John F. Kennedy, State Road 60, Cleveland, Rosband, Platt, Cleveland St, Dale, Horatio, De Leon, etc.) with north arrow; labels for EXISTING STORMWATER PIPES, EXISTING STORMWATER MANHOLES, EXISTING STORMWATER INLETS, PROP. STORM PIPES, PROP. STORM INLETS, PROP. STORM MANHOLES, and an 'AREA TO BE RESURFACED'.

Quantities this sheet can support

count of existing drainage structures (D-17 to D-23, 7 entries) with top/throat elevations and pipe invertscount of existing sanitary structures (S-4 to S-8, 5 entries) with invertscount of control points (points 101–113, 13 rows) with coordinates and elevationscount of water valves (V-1 to V-16, 16 entries) with rim/nut sizeslinear distances of horizontal alignment segments (1000.00' per segment, SRL1 and SRL2) with bearingspipe sizes noted in invert schedules (e.g. 30" ERCP, 18" RCP, 15" RCP, 8" VCP)

Key notes read from the sheet

  • Multiple existing structures carry the warning 'PIPES NOT VERIFIED DUE TO EXCESSIVE TRAFFIC' (e.g. S-7, S-8, D-22, D-23).
  • Project Location Map is explicitly labeled 'NOT TO SCALE'.
  • The map distinguishes EXISTING vs PROP. (proposed) stormwater pipes, inlets, and manholes and marks an 'AREA TO BE RESURFACED'.
  • Pipe legend differentiates sizes: 'UP TO 18" & SMALLER' vs '24" & LARGER'.

Every line on the sheet is typed by what it is: a structure callout, a station, an invert value, a utility witness tag, a proposed or existing note. That is what makes an annotation addressable rather than merely readable. Hover a row to light every instance of that type on the sheet.

Annotation typeCountExample
Structure callout28V-10
Station3311+54.74
Proposed work callout5PROP. STORM MANHOLES
Existing condition callout6EXISTING STORMWATER MANHOLES
Invert or rim value3230" ERCP INV(SW)=4.18
Pipe or utility spec1018" RCP(NW)=4.75
Utility witness tag8OHL
Spot elevation913.85
Note or long string17LEGEND, PROJECT MAP AND EX. INVERTS
Other lettering423BT(B) — - - - - BT(B) — -

Surveyed symbols found on this sheet, named by the set's own legend. Hover a class to light every instance at once. Counts are reported as found, never adjusted to match an expectation.

Legend classCount
pedestrian signal1
shared utility pole1
reclaimed water valve cover1
sanitary manhole1
drainage manhole1
mailbox1
gas regulator1
water valve cover1
telephone pedestal1
cleanout1
fire hydrant1
water meter1
telephone manhole1
single support sign1
iron rod1
concrete monument1
nail and disk1
light pole1
post1
iron pipe1

Every instance, with the callouts printed beside it

Each located symbol, and the text on the sheet within reach of it, nearest first. Distances are real feet at the sheet scale, not pixels. Where a callout carries an identifier that names this kind of feature, it is promoted to ID; proximity alone does not establish labelling, agreement does. Hover a row to zoom to that symbol.

SymbolStationIDCallouts within reach
light pole24+63.45·nothing within reach
water meter24+63.70·S
shared utility pole24+63.70·nothing within reach
drainage manhole24+63.80·S
gas regulator24+63.80·nothing within reach
sanitary manhole24+63.85·S
fire hydrant24+63.75·nothing within reach
nail and disk24+63.70·nothing within reach
iron rod24+63.80·nothing within reach
concrete monument24+63.80·nothing within reach
iron pipe24+63.80·nothing within reach
pedestrian signal25+25.96·nothing within reach
single support sign25+25.76·nothing within reach
reclaimed water valve cover25+25.76·RCW  W  G
water valve cover25+25.76·W  RCW  G
mailbox25+25.91·nothing within reach
cleanout25+25.86·RCW
telephone manhole25+25.81·nothing within reach
telephone pedestal25+26.11·nothing within reach
post25+25.91·nothing within reach

571 lines read from this sheet, including rotated title block lettering. The 400 longest are listed here. Hover a row to zoom to it on the sheet.

TextConfidenceType
LEGEND, PROJECT MAP AND EX. INVERTS0.999Note or long string
Professional Surveyor and Mapper1.0Note or long string
Stormwater Engineering Division1.0Note or long string
Valve Cover - Reclaimed Water0.993Note or long string
EXISTING STORMWATER MANHOLES0.995Existing condition callout
Sanitary Sewer Gravity Line1.0Note or long string
STA 27+59.17 23.21' LT SRL20.988Note or long string
STA 18+45.82 18.35' LT SRL10.998Note or long string
STA 27+38.74 26.07' RT SRL20.985Note or long string
STA 23+19.90 20.30' RT SRL20.997Note or long string
STA 27+38.97 37.23' RT SRL20.997Note or long string
STA 24+96.14 19.81' RT SRL20.984Note or long string
STA 28+10.83 63.89' RT SRL20.983Note or long string
STA 28+25.86 30.06' RT SRL20.983Note or long string
STA 28+40.39 71.33' RT SRL20.977Note or long string
STA 28+25.95 18.65' RT SRL20.979Note or long string
STA 28+18.55 25.52' RT SRL20.997Note or long string
STA 23+19.90 20.30'RT SRL20.985Note or long string
EXISTING STORMWATER INLETS0.993Existing condition callout
BT(B) — - - - - BT(B) — -0.804Other lettering
3TA 18+45.8218.33 LT 3RL10.836Other lettering
Global Positioning System1.0Other lettering
High Density Polyethylene1.0Other lettering
EXISTING STORMWATER PIPES0.997Existing condition callout
Electrical Cable Or Duct1.0Other lettering
National Geodetic Survey0.999Other lettering
Reinforced Concrete Pipe1.0Other lettering
Buried Fiber Optic Cable1.0Other lettering
DUE TO EXCESSIVE TRAFFIC0.985Other lettering
DUE TO EXCESSIVE TRAFFIC0.995Other lettering
DUE TO EXCESSIVE TRAFFIC0.97Other lettering
DUE TO EXCESSIVE TRAFFIC0.992Other lettering
Telephone Cable Or Duct1.0Other lettering
EX. SANITARY STRUCTURES0.998Existing condition callout
EX. DRAINAGE STRUCTURES0.996Existing condition callout
Overhang/Awning/Canopy1.0Other lettering
STA 28+17.84 43.82' RT0.992Other lettering
WOODMERE & LOIS AVENUE0.986Other lettering
Set 1/2" Iron Rod GFY1.0Other lettering
Set 1/2" Iron Rod GFY1.0Other lettering
Set 1/2" Iron Rod GFY1.0Other lettering
Set 1/2" Iron Rod GFY1.0Other lettering
Set 1/2" Iron Rod GFY0.999Other lettering
Set 1/2" Iron Rod GFY1.0Other lettering
Set 1/2" Iron Rod GFY1.0Other lettering
Set 1/2" Iron Rod GFY1.0Other lettering
Set 1/2" Iron Rod GFY1.0Other lettering
Set 1/2" Iron Rod GFY0.999Other lettering
Set 1/2" Iron Rod GFY0.998Other lettering
30" ERCP INV(SW)=4.180.985Invert or rim value
18" ERCP INV(NW)=4.340.995Invert or rim value
CURB INLET W/ MANHOLE0.998Other lettering
Witness - Fiber Optic0.993Other lettering
CURB INLET W/ MANHOLE0.999Other lettering
FING CTORMWATER PIREC0.838Other lettering
CURB INLET W/ MANHOLE0.999Other lettering
AREA TO BE RESURFACED1.0Other lettering
DRAINAGE IMPROVEMENTS1.0Other lettering
Tree Protection Zone1.0Other lettering
ABBREVIATION LEGEND:1.0Other lettering
18" RCP INV(SE)=4.600.98Invert or rim value
8" VCP INV(SE)=10.080.987Invert or rim value
8" VCP INV(SSE)=6.350.975Invert or rim value
18" RCP INV(NW)=7.270.996Invert or rim value
PROP. STORM MANHOLES0.996Proposed work callout
PROJECT LOCATION MAP0.997Other lettering
Set Nail & Disk GFY1.0Other lettering
Set Nail & Disk GFY1.0Other lettering
Single Support Sign1.0Other lettering
1O"EDCD INV/NA—4 240.796Invert or rim value
Witness - Telephone0.994Other lettering
Valve Cover - Water1.0Other lettering
Vitrified Clay Pipe0.999Other lettering
15" RCP INV(W)=8.230.987Invert or rim value
Shared Utility Pole1.0Other lettering
18" RCP INV(N)=7.300.994Invert or rim value
18" RCP INV(S)=7.610.994Invert or rim value
Mobility Department1.0Other lettering
8" VCP INV(W)=6.080.977Invert or rim value
8" VCP INV(E)=6.490.994Invert or rim value
8" VCP INV(N)=9.450.991Invert or rim value
Manhole - Drainage0.998Other lettering
Manhole - Sanitary1.0Other lettering
Polyvinyl Chloride1.0Other lettering
8" VCP INV(S)=8.610.995Invert or rim value
8" VCP INV(N)=8.750.979Invert or rim value
8" VCP INV(E)=8.660.978Invert or rim value
PIPES NOT VERIFIED0.996Other lettering
PROP. STORM INLETS0.968Proposed work callout
PIPES NOT VERIFIED0.997Other lettering
PIPES NOT VERIFIED0.993Other lettering
PIPES NOT VERIFIED0.999Other lettering
Concrete Monument1.0Other lettering
Pedestrian Signal1.0Other lettering
Telepone Pedestal1.0Other lettering
Licensed Business1.0Other lettering
Licensed Surveyor1.0Other lettering
THROAT ELEV=11.781.0Invert or rim value
PROP. STORM PIPES0.993Proposed work callout
THROAT ELEV=11.961.0Invert or rim value
PROP. STORM PIPES0.995Proposed work callout
DRAINAGE MANHOLE1.0Other lettering
SANITARY MANHOLE0.991Other lettering
DRAINAGE MANHOLE1.0Other lettering
Telepone Manhole1.0Other lettering
SANITARY MANHOLE1.0Other lettering
18" RCP(NW)=4.750.975Pipe or utility spec
SANITARY MANHOLE0.999Other lettering
SANITARY MANHOLE0.999Other lettering
HATCHING LEGEND:0.998Other lettering
SANITARY MANHOLE1.0Other lettering
DRAINAGE MANHOLE1.0Other lettering
DRAINAGE MANHOLE1.0Other lettering
Reclaimed Water1.0Other lettering
Chainlink Fence1.0Other lettering
18" RCP(S)=5.880.992Pipe or utility spec
15" RCP(E)=7.750.982Pipe or utility spec
JOHN F. KENNEDY0.998Other lettering
CONTROL POINTS0.996Other lettering
Overhead Lines1.0Other lettering
SYMBOL LEGEND:1.0Other lettering
TOP ELEV=10.520.999Invert or rim value
TOP ELEV=13.691.0Invert or rim value
Elliptical RCP1.0Pipe or utility spec
TOP ELEV=12.001.0Invert or rim value
TOP ELEV=13.521.0Invert or rim value
TOP ELEV=12.411.0Invert or rim value
TOP ELEV=13.241.0Invert or rim value
TOP ELEV=12.831.0Invert or rim value
EXISTING STORI0.985Existing condition callout
TOP ELEV=11.601.0Invert or rim value
TOP ELEV=12.851.0Invert or rim value
TOP ELEV=11.461.0Invert or rim value
TOP ELEV=11.531.0Invert or rim value
TOP ELEV=11.821.0Invert or rim value
DATE: 05/21/250.968Other lettering
Drainage Pipe1.0Other lettering
S 89°19'55" E0.993Other lettering
N 00°48'12" E0.969Other lettering
Gas Regulator1.0Other lettering
Meter - Water0.993Other lettering
STATE ROAD 601.0Other lettering
Witness - Gas1.0Other lettering
Nail and Disk1.0Other lettering
CITY of TAMPA0.971Other lettering
24" & LARGER0.998Other lettering
WATER VALVES0.999Other lettering
Fire Hydrant1.0Other lettering
EXICTIG-CTOR0.837Other lettering
ott a a 0250.641Other lettering
NOT TO SCALE1.0Other lettering
Description1.0Other lettering
W. DALE AVE0.999Other lettering
S. LOIS AVE0.999Other lettering
SW 2023-140.993Other lettering
386.26' LT0.97Other lettering
1311409.431.0Other lettering
1311031.601.0Other lettering
1311041.901.0Other lettering
1311007.621.0Other lettering
1311390.171.0Other lettering
1311614.901.0Other lettering
223.64' LT0.965Other lettering
1311452.741.0Other lettering
1311164.491.0Other lettering
1310838.421.0Other lettering
177.04' RT0.977Other lettering
1311025.001.0Other lettering
1311013.351.0Other lettering
1310873.861.0Other lettering
1311873.761.0Other lettering
1311025.001.0Other lettering
1311013.351.0Other lettering
1310873.861.0Other lettering
1311873.761.0Other lettering
Arc Length1.0Other lettering
Light Pole1.0Other lettering
Alignment1.0Other lettering
UP TO 18"0.999Other lettering
489505.081.0Other lettering
& SMALLER0.999Other lettering
489558.231.0Other lettering
24.37' LT0.977Other lettering
489988.841.0Other lettering
490168.631.0Other lettering
490215.011.0Other lettering
39.63' RT0.954Other lettering
490157.511.0Other lettering
21.02' LT0.988Other lettering
489952.601.0Other lettering
ALIGNMENT1.0Other lettering
42.14' LT0.97Other lettering
490177.791.0Other lettering
60.24' LT0.97Other lettering
RECLAIMED1.0Other lettering
490163.461.0Other lettering
66.53' LT0.967Other lettering
RECLAIMED1.0Other lettering
489345.851.0Other lettering
32.91' LT0.974Other lettering
490345.781.0Other lettering
10.53' RT0.953Other lettering
16.76' LT0.966Other lettering
490168.141.0Other lettering
30.57' LT0.949Other lettering
RECLAIMED1.0Other lettering
490182.161.0Other lettering
25.77' LT0.968Other lettering
RECLAIMED1.0Other lettering
48.82' RT0.969Other lettering
45.00' RT0.965Other lettering
RECLAIMED1.0Other lettering
58.80' LT0.975Other lettering
RECLAIMED1.0Other lettering
53.41' LT0.947Other lettering
RECLAIMED1.0Other lettering
ALIGNMENT1.0Other lettering
Bank Line1.0Other lettering
48.80' RT0.968Other lettering
RECLAIMED1.0Other lettering
489345.851.0Other lettering
490345.781.0Other lettering
490168.141.0Other lettering
490182.161.0Other lettering
Elevation1.0Other lettering
Iron Pipe1.0Other lettering
PVC Fence0.949Pipe or utility spec
CLEVELAND1.0Other lettering
PROP. STC0.935Proposed work callout
REVISIONS1.0Other lettering
REVISIONS1.0Other lettering
Northing1.0Other lettering
11+54.741.0Station
9.03' LT0.966Other lettering
12+12.291.0Station
16+42.751.0Station
1.39' LT0.986Other lettering
21+33.751.0Station
25+16.921.0Station
27+40.811.0Station
25+75.811.0Station
11+50.311.0Station
22+90.731.0Station
5.57' RT0.958Other lettering
11+89.491.0Station
18+19.731.0Station
66.53'LT1.0Other lettering
11+93.251.0Station
0.00' RT0.984Other lettering
10+00.001.0Station
13+00.281.0Station
0.00' RT0.984Other lettering
20+00.001.0Station
18+28.321.0Station
18+75.731.0Station
0.00' RT0.983Other lettering
20+00.001.0Station
18+99.821.0Station
0.00' RT0.948Other lettering
30+00.001.0Station
25.77'LT1.0Other lettering
19+01.181.0Station
7.48' RT0.959Other lettering
24+87.591.0Station
25+03.911.0Station
27+53.851.0Station
28+04.771.0Station
28+04.361.0Station
1.26' LT0.946Other lettering
28+45.581.0Station
6.25' RT0.973Other lettering
28+57.401.0Station
NORTHING1.0Other lettering
DISTANCE1.0Other lettering
28+53.011.0Station
10+00.001.0Station
1000.00'1.0Other lettering
20+00.001.0Station
20+00.001.0Station
1000.00'1.0Other lettering
30+00.001.0Station
Concrete1.0Other lettering
Guy Wire1.0Other lettering
Iron Rod1.0Other lettering
Cleanout1.0Other lettering
Concrete1.0Other lettering
COOLIDGE0.955Other lettering
WOCDMERE0.916Other lettering
WOODMERE0.999Other lettering
LEGEND:1.0Other lettering
Easting1.0Other lettering
Station1.0Other lettering
POTABLE1.0Other lettering
POTABLE1.0Other lettering
POTABLE1.0Other lettering
POTABLE1.0Other lettering
POTABLE1.0Other lettering
POTABLE1.0Other lettering
POTABLE1.0Other lettering
6.25'RT1.0Other lettering
POTABLE1.0Other lettering
EASTING1.0Other lettering
STATION1.0Other lettering
BEARING1.0Other lettering
Mailbox1.0Other lettering
KRENTEL0.911Other lettering
Tac Mat0.937Other lettering
HORATIO1.0Other lettering
DE LEON0.999Other lettering
ot 1 250.782Other lettering
Offset1.0Other lettering
DTABLE0.992Other lettering
DTABLE0.987Other lettering
13.94'1.0Other lettering
13.62'1.0Other lettering
DTABLE0.987Other lettering
13.96'1.0Other lettering
11.83'1.0Other lettering
DTABLE0.987Other lettering
10.97'1.0Other lettering
14.66'1.0Other lettering
14.74'0.998Other lettering
11.41'0.996Other lettering
13.44'1.0Other lettering
13.59'1.0Other lettering
DTABLE0.987Other lettering
13.22'1.0Other lettering
11.33'1.0Other lettering
DTABLE0.993Other lettering
13.08'1.0Other lettering
10.62'1.0Other lettering
10.09'1.0Other lettering
10.29'1.0Other lettering
DTABLE0.985Other lettering
11.44'1.0Other lettering
10.41'1.0Other lettering
11.75'1.0Other lettering
10.88'0.986Other lettering
DTABLE0.993Other lettering
STREET1.0Other lettering
12.19'1.0Other lettering
- RCW-0.96Other lettering
Invert1.0Other lettering
Cleand0.923Other lettering
ROLAND1.0Other lettering
ROLAND1.0Other lettering
AZEELE1.0Other lettering
HUBERT0.906Other lettering
Point1.0Other lettering
13.851.0Spot elevation
13.761.0Spot elevation
10.881.0Spot elevation
3.93'0.999Other lettering
5.66'1.0Other lettering
13.741.0Spot elevation
5.74'1.0Other lettering
4.65'1.0Other lettering
15.051.0Spot elevation
5.24'1.0Other lettering
5.57'1.0Other lettering
5.63'1.0Other lettering
4.88'1.0Other lettering
Fence0.994Other lettering
8.21'0.999Other lettering
8.67'1.0Other lettering
9.96'1.0Other lettering
-RCW-0.944Other lettering
Water1.0Other lettering
CONC.1.0Other lettering
GRADY0.834Other lettering
RETEL0.876Other lettering
PLATT1.0Other lettering
PLATT1.0Other lettering
PLATT1.0Other lettering
ROBIN1.0Other lettering
BEACH1.0Other lettering
HUERT0.925Other lettering
_LARK0.672Other lettering
GRADY0.869Other lettering
SWANN1.0Other lettering
SHEET1.0Other lettering
Elev1.0Other lettering
6.001.0Spot elevation
SRL11.0Other lettering
SRL11.0Other lettering
5.841.0Spot elevation
8.971.0Spot elevation
SRL11.0Other lettering
SRL21.0Other lettering
SRL21.0Other lettering
SRL21.0Other lettering
7.951.0Spot elevation
SRL21.0Other lettering
NAME1.0Other lettering
TYPE1.0Other lettering
SRL11.0Other lettering
SRL21.0Other lettering
SRL11.0Other lettering
SRL11.0Other lettering
SRL11.0Other lettering

The sheet as continuous text, in the order a person would read it. Note columns become prose, printed tables stay tables.

SW 2023-14

LEGEND:

ABBREVIATION LEGEND:

A Arc Length CLF Chainlink Fence CONC. Concrete ELEV Elevation ERCP Elliptical RCP GPS Global Positioning System HDPE High Density Polyethylene INV Invert LB Licensed Business LS Licensed Surveyor NGS National Geodetic Survey PSM Professional Surveyor and Mapper PVC Polyvinyl Chloride PVCF PVC Fence RCP Reinforced Concrete Pipe VCP Vitrified Clay Pipe BFOC Buried Fiber Optic Cable

SYMBOL LEGEND:

Concrete Monument Fire Hydrant Gas Regulator Guy Wire Iron Pipe Iron Rod Light Pole Manhole - Drainage Manhole - Sanitary Meter - Water Nail and Disk Shared Utility Pole Single Support Sign Witness - Telephone Pedestrian Signal Telephone Pedestal Telephone Manhole Mailbox Post Cleanout Valve Cover - Reclaimed Water Valve Cover - Water Witness - Gas Witness - Fiber Optic

HATCHING LEGEND:

Concrete Tac Mat

CONTROL POINTS

PointStationOffsetAlignmentNorthingEastingElevDescription
10111+54.74386.26' LTSRL11311409.43489505.086.00Set 1/2" Iron Rod GFY
10212+12.299.03' LTSRL11311031.60489558.235.84Set Nail & Disk GFY
10316+42.7524.37' LTSRL11311041.90489988.848.97Set 1/2" Iron Rod GFY
10421+33.751.39' LTSRL21311007.62490168.6313.85Set 1/2" Iron Rod GFY
10525+16.9239.63' RTSRL21311390.17490215.0113.76Set 1/2" Iron Rod GFY
10627+40.8121.02' LTSRL21311614.90490157.5110.88Set 1/2" Iron Rod GFY
10725+75.81223.64' LTSRL21311452.74489952.607.95Set Nail & Disk GFY
10822+90.735.57' RTSRL21311164.49490177.7913.74Set 1/2" Iron Rod GFY
10918+19.73177.04' RTSRL11310838.42490163.4615.05Set 1/2" Iron Rod GFY
11010+00.000.00' RTSRL11311025.00489345.85N/ASet 1/2" Iron Rod GFY
11120+00.000.00' RTSRL11311013.35490345.78N/ASet 1/2" Iron Rod GFY
11220+00.000.00' RTSRL21310873.86490168.14N/ASet 1/2" Iron Rod GFY
11330+00.000.00' RTSRL21311873.76490182.16N/ASet 1/2" Iron Rod GFY

WATER VALVES

NAMESTAOFFALIGNMENTTYPERIMNUT
V-111+50.3142.14' LTSRL1POTABLE5.66'3.93'
V-211+89.4960.24' LTSRL1RECLAIMED5.74'4.65'
V-311+93.2566.53' LTSRL1RECLAIMED5.57'5.24'
V-413+00.2832.91' LTSRL1POTABLE5.63'4.88'
V-518+28.3210.53' RTSRL1POTABLE13.94'13.62'
V-618+75.7316.76' LTSRL1POTABLE13.96'11.83'
V-718+99.8230.57' LTSRL1RECLAIMED14.66'10.97'
V-819+01.1825.77' LTSRL1RECLAIMED14.74'11.41'
V-924+87.597.48' RTSRL2POTABLE13.59'13.44'
V-1025+03.9148.82' RTSRL2POTABLE13.22'11.33'
V-1127+53.8545.00' RTSRL2RECLAIMED13.08'10.62'
V-1228+04.7758.80' LTSRL2RECLAIMED10.09'8.21'
V-1328+04.3653.41' LTSRL2RECLAIMED10.29'8.67'
V-1428+45.581.26' LTSRL2POTABLE11.44'10.41'
V-1528+57.406.25' RTSRL2POTABLE11.75'10.88'
V-1628+53.0148.80' RTSRL2RECLAIMED12.19'9.96'

ALIGNMENT

NAMESTREETSTATIONNORTHINGEASTINGBEARINGDISTANCE
SRL1W. DALE AVE10+00.001311025.00489345.85S 89°19'55" E1000.00'
20+00.001311013.35490345.78
SRL2S. LOIS AVE20+00.001310873.86490168.14N 00°48'12" E1000.00'
30+00.001311873.76490182.16

PROJECT LOCATION MAP NOT TO SCALE

EX. DRAINAGE STRUCTURES

D-17 DRAINAGE MANHOLE STA 27+59.17 23.21' LT SRL2 TOP ELEV=10.52 30" ERCP INV(SW)=4.18 18" ERCP INV(NW)=4.34 18" RCP INV(SE)=4.60

D-18 DRAINAGE MANHOLE STA 27+38.74 26.07' RT SRL2 TOP ELEV=12.00 18" RCP(NW)=4.75 18" RCP(S)=5.88 15" RCP(E)=7.75

D-19 CURB INLET W/ MANHOLE STA 27+38.97 37.23' RT SRL2 TOP ELEV=12.41 15" RCP INV(W)=8.23

D-20 CURB INLET W/ MANHOLE STA 28+10.83 63.89' RT SRL2 TOP ELEV=12.83 THROAT ELEV=11.78 18" RCP INV(N)=7.30 18" RCP INV(NW)=7.27

D-21 CURB INLET W/ MANHOLE STA 28+40.39 71.33' RT SRL2 TOP ELEV=12.85 THROAT ELEV=11.96 18" RCP INV(S)=7.61

D-22 DRAINAGE MANHOLE STA 28+18.55 25.52' RT SRL2 TOP ELEV=11.53 PIPES NOT VERIFIED DUE TO EXCESSIVE TRAFFIC

D-23 DRAINAGE MANHOLE STA 28+17.84 43.82' RT TOP ELEV=11.82 PIPES NOT VERIFIED DUE TO EXCESSIVE TRAFFIC

EX. SANITARY STRUCTURES

S-4 SANITARY MANHOLE STA 18+45.82 18.35' LT SRL1 TOP ELEV=13.69 8" VCP INV(W)=6.08 8" VCP INV(E)=6.49 8" VCP INV(SE)=10.08 8" VCP INV(SSE)=6.35

S-5 SANITARY MANHOLE STA 23+19.90 20.30' RT SRL2 TOP ELEV=13.52 8" VCP INV(N)=9.45

S-6 SANITARY MANHOLE STA 24+96.14 19.81' RT SRL2 TOP ELEV=13.24 8" VCP INV(S)=8.61 8" VCP INV(N)=8.75 8" VCP INV(E)=8.66

S-7 SANITARY MANHOLE STA 28+25.86 30.06' RT SRL2 TOP ELEV=11.60 PIPES NOT VERIFIED DUE TO EXCESSIVE TRAFFIC

S-8 SANITARY MANHOLE STA 28+25.95 18.65' RT SRL2 TOP ELEV=11.46 PIPES NOT VERIFIED DUE TO EXCESSIVE TRAFFIC

No.DATEREVISIONSNo.DATEREVISIONSDES: SEB
36DRN: BB
25CKD: JDM
14DATE: 05/21/25

CITY of TAMPA Mobility Department Stormwater Engineering Division

WOODMERE & LOIS AVENUE DRAINAGE IMPROVEMENTS LEGEND, PROJECT MAP AND EX. INVERTS

SHEET 2

OF 9

Every printed table on this sheet, recovered as rows and cells.

Control points

CONTROL POINTS
PointStationOffsetAlignmentNorthingEastingElevDescription
10111+54.74386.26' LTSRL11311409.43489505.086.00Set 1/2" Iron Rod GFY
10212+12.299.03' LTSRL11311031.60489558.235.84Set Nail & Disk GFY
10316+42.7524.37' LTSRL11311041.90489988.848.97Set 1/2" Iron Rod GFY
10421+33.751.39' LTSRL21311007.62490168.6313.85Set 1/2" Iron Rod GFY
10525+16.9239.63' RTSRL21311390.17490215.0113.76Set 1/2" Iron Rod GFY
10627+40.8121.02' LTSRL21311614.90490157.5110.88Set 1/2" Iron Rod GFY
10725+75.81223.64' LTSRL21311452.74489952.607.95Set Nail & Disk GFY
10822+90.735.57' RTSRL21311164.49490177.7913.74Set 1/2" Iron Rod GFY
10918+19.73177.04' RTSRL11310838.42490163.4615.05Set 1/2" Iron Rod GFY
11010+00.000.00' RTSRL11311025.00489345.85N/ASet 1/2" Iron Rod GFY
11120+00.000.00' RTSRL11311013.35490345.78N/ASet 1/2" Iron Rod GFY
11220+00.000.00' RTSRL21310873.86490168.14N/ASet 1/2" Iron Rod GFY
11330+00.000.00' RTSRL21311873.76490182.16N/ASet 1/2" Iron Rod GFY

Alignment

ALIGNMENT
NAMESTREETSTATIONNORTHINGEASTINGBEARINGDISTANCE
SRL1W. DALE AVE10+00.001311025.00489345.85S 89°19'55" E1000.00'
SRL2S. LOIS AVE20+00.001311013.35490345.78
20+00.001310873.86490168.14N 00°48'12" E
30+00.001311873.76490182.16

Water valves

NAME | STA | OFF | ALIGNMENT | TYPE | RIM | NUT V-1 | 11+50.31 | 42.14' LT | SRL1 | POTABLE | 5.66' | 3.93' V-2 | 11+89.49 | 60.24' LT | SRL1 | RECLAIMED | 5.74' | 4.65' V-3 | 11+93.25 | 66.53' LT | SRL1 | RECLAIMED | 5.57' | 5.24' V-4 | 13+00.28 | 32.91' LT | SRL1 | POTABLE | 5.63' | 4.88' V-5 | 18+28.32 | 10.53' RT | SRL1 | POTABLE | 13.94' | 13.62' V-6 | 18+75.73 | 16.76' LT | SRL1 | POTABLE | 13.96' | 11.83' V-7 | 18+99.82 | 30.57' LT | SRL1 | RECLAIMED | 14.66' | 10.97' V-8 | 19+01.18 | 25.77' LT | SRL1 | RECLAIMED | 14.74' | 11.41' V-9 | 24+87.59 | 7.48' RT | SRL2 | POTABLE | 13.59' | 13.44' V-10 | 25+03.91 | 48.82' RT | SRL2 | POTABLE | 13.22' | 11.33' V-11 | 27+53.85 | 45.00' RT | SRL2 | RECLAIMED | 13.08' | 10.62' V-12 | 28+04.77 | 58.80' LT | SRL2 | RECLAIMED | 10.09' | 8.21' V-13 | 28+04.36 | 53.41' LT | SRL2 | RECLAIMED | 10.29' | 8.67' V-14 | 28+45.58 | 1.26' LT | SRL2 | POTABLE | 11.44' | 10.41' V-15 | 28+57.40 | 6.25' RT | SRL2 | POTABLE | 11.75' | 10.88' V-16 | 28+53.01 | 48.80' RT | SRL2 | RECLAIMED | 12.19' | 9.96'

Revision block

No. | DATE | REVISIONS | No. | DATE | REVISIONS | DE | DR | CK 3 | | | 6 | | | | DR | CK

Sheet
3 of 9 general
Text lines
576 each located on the sheet
Symbols
0 0 classes
Viewports
3 titled drawings found

WOODMERE & LOIS AVENUE DRAINAGE IMPROVEMENTS NOTES SHEET

This is a text‑only notes sheet for the Woodmere & Lois Avenue stormwater drainage improvements project (City of Tampa, Mobility Department, Stormwater Engineering Division). It does not show any graphic plan, profile, or section; instead it provides the contractual and construction instructions the contractor must follow, organized into General Notes, Construction Notes, Utilities, Erosion & Sediment Control, Demolition, Bidding Notes, and Environmental Protection. It governs vertical datums, utility location and restoration, traffic‑signal coordination, pipe and manhole standards, erosion/sediment control measures, demolition and waste disposal, and bidding/environmental requirements for the drainage work.

Viewports

TitleKindScaleContents
Revisions / Revisions tableschedule block (table)noneA two‑column 'No. / DATE / REVISIONS' revision log (rows numbered 4–6) plus a design‑stamp block listing DES: SEB, DKN: JB, CKO: JDM, DATE: 05/21/25.
Title blocklegend/title blocknoneCity of Tampa seal, 'Mobility Department / Stormwater Engineering Division', project title 'WOODMERE & LOIS AVENUE DRAINAGE IMPROVEMENTS NOTES SHEET', and sheet number '3 of 9'.
Note blocks (General / Construction / Utilities / Erosion & Sediment Control / Demolition / Bidding / Environmental Protection)table (text note blocks, no graphic drawing)noneNumbered paragraph text giving instructions; no graphical plan, profile, map, section, or detail is drawn anywhere on this sheet.

Quantities this sheet can support

none measurable for a quantity takeoff — the sheet is a notes sheet containing no graphical lines, structures, pipe runs, or structures to count; only counts of note items (e.g., numbered note clauses) and a design‑revision stamp are present

Key notes read from the sheet

  • ELEVATIONS SHOWN HEREON ARE BASED ON THE NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD88) AND UTILIZE CITY OF TAMPA BENCHMARK HV-02072, HAVING AN ELEVATION OF 13.855', NAVD 88.
  • BEARINGS AND COORDINATES SHOWN HEREON ARE BASED ON THE FLORIDA STATE PLANE COORDINATE SYSTEM, WEST ZONE AS REFERENCED TO THE NORTH AMERICAN DATUM 1983, ADJUSTMENT OF 2011, NAD83(2011) AND ARE SHOWN IN US SURVEY FEET.
  • THE CONTRACTOR SHALL CALL SUNSHINE (1-800-432-4770) AT LEAST 72 HOURS PRIOR TO ANY CONSTRUCTION ACTIVITIES.
  • ALL STORM SEWER PIPES SHALL BE REINFORCED CONCRETE PIPE (RCP), MINIMUM CLASS III, UNLESS OTHERWISE NOTED. STORM DRAIN INLET STRUCTURES SHALL BE PRECAST AND CONSTRUCTED IN ACCORDANCE WITH THE CITY OF TAMPA TECHNICAL STANDARDS AND STANDARD DETAILS.
  • COMPACTION FOR PIPE BACKFILL SHALL COMPLY WITH AASHTO T-99 (100%).
  • UTILIZE A TRAFFIC SIGNAL SPECIALTY SUBCONTRACTOR TO HANDLE ALL TRAFFIC SIGNAL WORK... AT THE INTERSECTION OF WOODMERE AND LOIS DURING THE ROAD CLOSURE.
  • NO OPEN BURNING WILL BE ALLOWED AT THE SITE UNLESS A PLAN IS APPROVED BY THE OWNER, ENGINEER AND THE APPROPRIATE REGULATORY AUTHORITY.
  • ALL PROPOSED CONSTRUCTION WITHIN LIMITS OF WORK AREAS ARE PART OF PIPE, INLET AND / OR MANHOLE CONSTRUCTION.
  • NO EXCAVATION SHALL EXTEND BELOW THE PERMITTED DESIGN DEPTHS OR ELEVATIONS SHOWN ON THE DRAWINGS UNLESS ADDITIONAL TESTING SUPPORTS SUCH OVER-EXCAVATION AND NO LOWER SEMI-CONFINING UNIT...
  • ALL BOX CULVERTS AND STORM PIPE SHALL BE WATER TIGHT. BOX CULVERT AND STORM PIPE TRENCH BACKFILL SHALL CONFORM TO FDOT STANDARD SPECIFICATION...

Every line on the sheet is typed by what it is: a structure callout, a station, an invert value, a utility witness tag, a proposed or existing note. That is what makes an annotation addressable rather than merely readable. Hover a row to light every instance of that type on the sheet.

Annotation typeCountExample
Proposed work callout2PROPERLY DISPOSED OF AT THE CONTRACTOR'S EXPENSE UNLESS ON-SITE USE IS
Existing condition callout2EXISTING PUBLIC AND PRIVATE UTILITIES. THE CONTRACTOR SHALL VERIFY THE
Invert or rim value2CLEANOUTS AND SERVICE CONNECTIONS: MANHOLE RIM AND INVERT ELEVA TIONS:
Pipe or utility spec221. ALL STORM SEWER PIPES SHALL BE REINFORCED CONCRETE PIPE (RCP), MINIMUM
Note or long string4321. LOCA TIONS, ELEVA TIONS AND DIMENSIONS OF THE EXISTING UTILITIES, STRUCTURES
Other lettering136LOCATIONS, ELEVATIONS, AI

Surveyed symbols found on this sheet, named by the set's own legend. Hover a class to light every instance at once. Counts are reported as found, never adjusted to match an expectation.

Legend classCount
None detected on this sheet.

Every instance, with the callouts printed beside it

Each located symbol, and the text on the sheet within reach of it, nearest first. Distances are real feet at the sheet scale, not pixels. Where a callout carries an identifier that names this kind of feature, it is promoted to ID; proximity alone does not establish labelling, agreement does. Hover a row to zoom to that symbol.

SymbolStationIDCallouts within reach
None.

576 lines read from this sheet, including rotated title block lettering. The 400 longest are listed here. Hover a row to zoom to it on the sheet.

TextConfidenceType
1. LOCA TIONS, ELEVA TIONS AND DIMENSIONS OF THE EXISTING UTILITIES, STRUCTURES0.985Note or long string
LOCA TIONS, ELEVA TIONS, AND DIMENSIONS, OF ALL EXISTING UTILITIES, STRUCTURE,0.976Note or long string
6. CITY OWNED UTILITIES WITHIN THE PROJECT LIMITS INCLUDE WA TER, WASTEWA TER,0.982Note or long string
SEEDING. MULCHING. GEOTEXTILES. SOD STABILIZA TION. SWALE SODDING. VEGETA TIVE0.961Note or long string
LOCA TIONS, ELEVA TIONS AND DIMENSIONS OF ALL EXISTING UTILITIES, STRUCTURES,0.982Note or long string
UTILITIES ARE RESPONSIBLE FOR LOCATING THEIR UTILITIES PRIOR TO CONSTRUCTION0.997Note or long string
8. CONTRACTOR TO PROTECT EXISTING IRRIGATION SYSTEMS AND ANY OTHER UTILITIES0.988Note or long string
22. UPON FINAL PAVEMENT RESTORA TION, RE-STRIPE ROAD CENTERLINE TO EXISTING.0.99Note or long string
LOCA TION OF UNDERGROUND LINES. VERIZON TO RELOCA TE ANY CONFLICTING LINES.0.976Note or long string
9. THE SOLID WASTE DEPARTMENT (813-348-1146) IS TO BE NOTIFIED PRIOR TO ANY0.988Note or long string
5. ALL UTILITIES SHALL BE KEPT IN OPERATION EXCEPT WITH THE EXPRESS WRITTEN0.996Note or long string
TO PRESERVE EXISTING UTILITIES AND ANY AND ALL DAMAGE TO EXISTING UTILITIES0.979Note or long string
1. WHERE CONNECTIONS TO EXISTING DRIVES AND WALKS ARE NOT INDICA TED ON THE0.989Note or long string
13. UTILIZE A TRAFFIC SIGNAL SPECIALTY SUBCONTRACTOR TO HANDLE ALL TRAFFIC0.997Note or long string
1. STAKED OR FLOA TING SILT SCREENS, HAY BALES, OR OTHER APPROPRIA TE BEST0.986Note or long string
BY DIALING 811. FURTHER, THE CONTRACTOR IS CAUTIONED THAT THE SUNSHINE 8110.993Note or long string
DRAINAGE AND TRAFFIC SIGNAL CABLES. ALL OTHER UTILITIES PRESENT WITHIN THE0.996Note or long string
21. ALL STORM SEWER PIPES SHALL BE REINFORCED CONCRETE PIPE (RCP), MINIMUM0.988Pipe or utility spec
UTILITIES WHEN NOTED ON PLANS "TO BE RELOCATED BY OTHERS". INCLUDE UTILITY0.997Note or long string
9. RELOCATION PLANS FOR POTABLE AND RECLAIMED WA TER LINES SHALL BE ISSUED0.994Note or long string
VALVES, BENDS, SERVICE CONNECTIONS; WA TER LINE ELEVA TIONS AND CLEARANCES0.983Note or long string
1. ALL PROPOSED CONSTRUCTION WITHIN LIMITS OF WORK AREAS ARE PART OF PIPE.0.98Note or long string
2. ALL MA TERIALS DEMOLISHED OR REMOVED SHALL BE REMOVED FROM THE SITE AND0.992Note or long string
OR ELEVA TIONS. IF ANY LOWER SEMI-CONFINING UNIT CLAYEY SOIL MA TERIALS OR0.983Note or long string
ELEVATIONS, EXCAVA TION OPERATIONS SHALL IMMEDIA TELY CEASE IN THE GENERAL0.985Note or long string
3. PRIOR TO ANY GROUNDWATER DEWATERING ACTIVITIES. CONTRACTOR SHALL OBTAIN0.991Note or long string
1. ELEVATIONS SHOWN HEREON ARE BASED ON THE NORTH AMERICAN VERTICAL DATUM0.995Note or long string
SIGNAL WORK. COORDINA TE WITH THE CITY OF TAMPA'S SIGNAL MAINTENANCE SHOP0.989Note or long string
STAFF TO ADJUST SIGNAL TIMING AS NEEDED TO MAINTAIN PROPER TRAFFIC SIGNAL0.985Note or long string
ACHIEVE AN EROSION-FREE RESTORATION AREA (FREE FROM RUTTING. ETC.) TO THE0.969Note or long string
CONSENT OF THE UTILITY OWNER. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY0.991Note or long string
REQUIREMENTS OF THE STATE OR LOCAL AUTHORITY HAVING JURISDICTION OVER THE0.988Note or long string
VARIA TIONS SHALL NOT EXCEED 1/4 INCH UNDER TEN-FOOT (1O') STRAIGHT EDGE.0.987Note or long string
AND. IF REQUIRED. RELOCATED AND/OR TEMPORARILY SUPPORTING THEIR UTILITIES0.968Note or long string
7. CONTRACTOR SHALL INSPECT AND MAINTAIN ALL SEDIMENT AND EROSION CONTROL0.987Note or long string
6. THE CONTRACTOR SHALL PROTECT ALL TREES IN THE VICINITY OF THE PROPOSED0.991Note or long string
1. ALL INCIDENTAL PAVING, SIDEWALKS, BOLLARDS, FENCES, HEDGES, BUSHES AND0.991Note or long string
SPILLWAYS, SKIMMERS/BAFFLES, SUMPS AND UNDERDRAINS; TIES TO WA TER LINES,0.983Note or long string
ADDITIONAL INFORMATION ON EXISTING CONDITIONS. AN ELECTRONIC CADD DRAWING0.993Note or long string
7. PRIOR TO CONSTRUCTION CONTRACTOR TO RECORD LIMITS OF CONSTRUCTION AREA0.992Note or long string
DEWA TERING OR BYPASSING IN THE BID. NO ADDITIONAL COMPENSA TION SHALL BE0.987Note or long string
8. ALL BOX CULVERTS AND STORM PIPE SHALL BE WA TER TIGHT. BOX CULVERT AND0.983Note or long string
SPECIFICA TIONS 125. BOX CULVERT BACKFILLING WILL BE UNDER WET CONDITIONS0.992Note or long string
5. THE CONTRACTOR SHALL CALL SUNSHINE (1-800-432-4770) AT LEAST 72 HOURS0.992Note or long string
ALONG THE LIMITS OF CONSTRUCTION IS ALLOWED. IF NECESSARY, TO FACILITATE0.977Note or long string
INSTALLA TION OF SILT BARRIERS PROVIDING THAT DISTURBANCE IS THE MINIMUM0.987Note or long string
4. IF UTILITY FIELD LOCATION MARKINGS ARE REQUIRED, THE CONTRACTOR SHALL0.99Note or long string
BARRIERS SHALL CONTINUOUSLY AND FULLY ENCIRCLE ALL STOCKPILES WHICH WILL0.99Note or long string
SYSTEM MAY NOT REVEAL ALL ONSITE UTILITIES AND HIS FURTHER INVESTIGATION0.97Note or long string
17. CONTRACTOR SHALL RESTORE ALL NEIGHBORING RESIDENTIAL YARDS WITH LIKE0.991Note or long string
WITH AFFECTED UTILITY OWNER(S) AND SHALL ENDEAVOR TO COORDINA TE HIS OWN0.988Note or long string
11. ALL IMPROVEMENTS WITHIN PUBLIC RIGHTS-OF-WAY SHALL BE CONSTRUCTED IN0.997Note or long string
WITH THE PROJECT SPECIFICATIONS. AND THE LATEST EDITION OF CITY OF TAMPA0.966Note or long string
WITH THE ENGINEER FOR MAKING ANY AND ALL REQUIRED INTERPRETATIONS OF THE0.992Note or long string
20. CONTRACTOR TO PROTECT EXISTING PRIVATE FENCES DURING CONSTRUCTION OR0.992Note or long string
UTILITIES MUST PROVIDE THIS SERVICE WITHOUT CHARGING A FEE TO THE CITY'S0.984Note or long string
4. SEWER SERVICE LATERALS FOUND TO BE IN CONFLICT WITH THE WORK SHALL BE0.986Note or long string
23. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SUPPLYING A RECORD SURVEY(S)0.991Note or long string
5. DRIVEWAYS SHALL BE RECONSTRUCTED IN ACCORDANCE WITH CHAPTER 25 OF THE0.992Note or long string
PARKS & RECREATION DEPARTMENT, NA TURAL RESOURCES DIVISION, AND SHALL BE0.984Note or long string
TIES TO STORM SEWER LINES AND STORM STRUCTURE TOP AND INVERT ELEVATIONS;0.99Note or long string
WALKS, POLES, MANHOLES, VALVE BOXES, ETC.) FOUR COPIES OF THE SIGNED AND0.982Note or long string
3. NO OPEN BURNING WILL BE ALLOWED AT THE SITE UNLESS A PLAN IS APPROVED0.986Note or long string
4. CONTRACTOR SHALL REPAIR, IN KIND, ALL ADJACENT STRUCTURES, PAVEMENTS,0.997Note or long string
9. THE CONTRACTOR SHALL PERFORM ALL CONSTRUCTION BY THE LINES AND GRADES0.993Note or long string
COUNTY. E.P.C., AS APPLICABLE) PRIOR TO ANY FURTHER EXCAVA TION IN THESE0.979Note or long string
EXCEED 5% WITHOUT USE OF PROPER RAMPS FOR FDOT OR FLORIDA BUILDING CODE.0.993Note or long string
(MONUMENTS, PIPES, ETC.) FOR THE DURATION OF CONSTRUCTION. MARKERS SHALL0.986Note or long string
OF 1988 (NAVD88) AND UTILIZE CITY OF TAMPA BENCHMARK HV-02 O072, HAVING0.975Note or long string
3. BEARINGS AND COORDINATES SHOWN HEREON ARE BASED ON THE FLORIDA STATE0.994Note or long string
COMMUNICA TION. WA TER MAIN, WA TER SERVICES, SEWER LA TERALS AND OTHER0.958Note or long string
3. CONTRACTOR IS TO EXERCISE CAUTION WHEN OPERATING NEAR OR ADJACENT TO0.998Note or long string
7. PRIOR TO ANY CONSTRUCTION, CONTACT TECO GAS (813-275-3743) FOR EXACT0.987Note or long string
COORDINATE HIS CONSTRUCTION SCHEDULE WLTH ALL UTILITY COMPANIES AS WELL0.986Note or long string
3. OFF-SITE VEHICLE TRACKING OF SEDIMENT SHALL BE MINIMIZED BY CLEANING0.998Note or long string
WATERING. APPLICATION OF CALCIUM CHLORIDE OR OTHER PRIOR APPROVED MEANS0.982Note or long string
CONSTRUCTION, THE FDOT ROADWAY AND TRAFFIC DESIGN STANDARD INDEXES, AND0.996Note or long string
RESPONSIBILITY FOR CONSTRUCTING THE PROJECT TO ACCOMPLISH THE INTENT OF0.992Note or long string
TO ALLOW THE SAFE CONSTRUCTION OF THE WORK UNDER THIS CONTRACT. PRIVATE0.996Note or long string
7. COORDINATE RELOCATION, OR PROVISION OF TEMPORARY SUPPORT, OF PRIVATE0.984Note or long string
COORDINA TE ALL WA TER-RELA TED WORK WITH THE WA TER DEPARTMENT AND ITS0.979Note or long string
INCLUDING. BUT NOT LIMITED TO. LOCA TION AND FINISHED GRADE ELEVA TIONS0.96Note or long string
CONTROLS, SHALL BE DONE IN A TIMELY MANNER. BUT IN NO CASE LATER THAN 70.99Note or long string
CALENDAR DAYS FOLLOWING THE INSPECTION IN WHICH THE NEED IS IDENTIFIED.0.998Note or long string
TREES NOT SPECIFICALLY SHOWN TO BE REMOVED SHALL BE PROTECTED WLTH TREE0.983Note or long string
REQUIRED AT CERTAIN LOCATIONS AND SHALL BE COMPLETED IN ACCORDANCE WITH0.994Note or long string
SHALL BE DONE IN THE PRESENCE OF A CERTIFIED ARBORIST AND IN ACCORDANCE0.976Note or long string
2. PRICE FOR ALL REMOVAL. AS SHOWN ON THE PLANS OUTSIDE OF CONSTRUCTION0.993Note or long string
UTILITIES ARE TO BE PLACED IN SERVICE PRIOR TO CLOSEOUT OF THE PROJECT.0.991Note or long string
3. CONTRACTOR SHALL BE RESPONSIBLE FOR PULLING RIGHT-OF-WAY USE PERMITS0.997Note or long string
10. ALL GRADING OF SIDEWALKS AND PEDESTRIAN WALKWAYS SHALL MEET MINIMUM0.996Note or long string
WITHIN ROW LIMITS. CONTRACTOR SHALL AT BEST EFFORT PRESERVE ALL SPECIAL0.987Note or long string
2. CONSTRUCTION SHALL BE CARRIED OUT "IN THE DRY". THE CONTRACTOR SHALL0.994Note or long string
AND SHALL CONFORM SPECIFICALLY TO FDOT STANDARD SPECIFICATION 125.8.3.40.99Note or long string
PLANE COORDINATE SYSTEM. WEST ZONE AS REFERENCED TO THE NORTH AMERICAN0.99Note or long string
14. THE CONTRACTOR SHALL ENDEAVOR TO PROTECT ALL ADJACENT IMPROVEMENTS0.997Note or long string
DATUM 1983, ADJUSTMENT OF 2011, NAD83(2011) AND ARE SHOWN IN US SURVEY0.994Note or long string
4. STATIONS AND OFFSETS GIVEN ARE TO THE CENTER LINE OF THE INLETS AND0.997Note or long string
TELEPHONE AND OTHER COMMUNICATION CABLES AND CONDUIT WILL BE RELOCATED0.997Note or long string
SUBSTANTIAL COMPLETION. CONTRACTOR IS RESPONSIBLE FOR CONTROLLING SITE0.998Note or long string
813-228-4111 OR 813-275-3037) FOR EXACT LOCATION OF UNDERGROUND LINES.0.972Note or long string
EXISTING PUBLIC AND PRIVATE UTILITIES. THE CONTRACTOR SHALL VERIFY THE0.991Existing condition callout
INSTALLED, INCLUDING BACKFILLING IF NECESSARY, PRIOR TO ANY ADDITIONAL0.997Note or long string
8. PRIOR TO ANY CONSTRUCTION, CONTACT VERIZON (813-978-2164) FOR EXACT0.998Note or long string
16. REPAIR AND REPLACEMENT OF ALL PRIVATE AND PUBLIC PROPERTY AFFECTED0.974Note or long string
CONTRACTOR IS RESPONSIBLE FOR CONTACTING SUNSHINE 811 FOR THIS PURPOSE0.992Note or long string
SHALL BE RESTORED TO EXISTING CONDITIONS UP TO AND INCLUDING FROM BACK0.998Note or long string
18. THE CONTRACTOR SHALL CONTACT THE ENGINEER'S OFFICE IMMEDIA TELY ON0.99Note or long string
4. ALL FUGITIVE DUST SHALL BE CONTROLLED ON SITE. ONLY AREAS SCHEDULED0.977Note or long string
ANY CONFLICTS ARISING DURING CONSTRUCTION OF ANY IMPROVEMENTS SHOWN ON0.999Note or long string
FOR IMMEDIATE CONSTRUCTION SHALL BE CLEARED OR STRIPPED OF VEGETATION.0.989Note or long string
THESE DRAWINGS. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO CONSULT0.99Note or long string
BUFFER STRIPS, PROTECTION OF TREES, PRESERVATION OF MATURE VEGETATION,0.991Note or long string
2. STREET SIGNS, STREET MARKERS AND R-O-W MARKERS SHALL BE REMOVED AND0.996Note or long string
6. CONTRACTOR SHALL USE OTHER STRUCTURAL BMPS, AS NECESSARY, TO DIVERT0.991Note or long string
PRECAST AND CONSTRUCTED IN ACCORDANCE WITH THE CITY OF TAMPA TECHNICAL0.996Note or long string
3. CONTRACTOR SHALL RAISE OR LOWER EXISTING MANHOLE FRAME AND COVER TO0.992Note or long string
PRIOR TO COMMENCEMENT OF CONSTRUCTION ACTIVITIES. THE CONTRACTOR SHALL0.99Note or long string
DESIGNATED COORDINATOR TO AVOID CONFLICTS AND ENSURE PROPER SEQUENCING0.982Note or long string
8. ANY MAINTENANCE OPERATIONS NEEDED TO ASSURE PROPER OPERATION OF ALL0.995Note or long string
NO TREES SHALL BE PRUNED WITHOUT PRIOR APPROVAL FROM THE CITY OF TAMPA0.998Note or long string
BARRICADES FOR THE DURATION OF CONSTRUCTION. TREE LIMB OR ROOT PRUNING0.992Note or long string
CLEANOUTS AND SERVICE CONNECTIONS: MANHOLE RIM AND INVERT ELEVA TIONS:0.981Invert or rim value
SHALL BE DIMENSIONED FROM PERMANENT ABOVE GROUND STRUCTURES (BUILDINGS0.994Note or long string
PROPERLY DISPOSED OF AT THE CONTRACTOR'S EXPENSE UNLESS ON-SITE USE IS0.996Proposed work callout
CONDITION OF ONLY WATER AND SEWER UTILITIES SHALL BE PROVIDED IF THESE0.979Note or long string
4. CONTRACTOR SHALL BE RESPONSIBLE FOR PULLING RIGHT-OF-WAY USE PERMIT0.992Note or long string
5. CONTRACTOR RESPONSIBLE FOR OBTAINING TREE REMOVAL PERMITS AND GRAND0.99Note or long string
THESE MATERIALS ARE ENCOUNTERED WITHIN THE PERMITTED EXCAVATION DEPTHS0.996Note or long string
TO THE ATTENTION OF THE ENGINEER PRIOR TO THE USE OF THIS INFORMA TION0.981Note or long string
AND DOCUMENT ALL UNIQUE AND SPECIAL FEATURES OF RESIDENTIAL YARD AREAS0.998Note or long string
SIDEWALKS TO BE 2.O% MAX. SLOPE. ALL SIDEWALK RUNNING SLOPES SHALL NOT0.998Note or long string
REVIEW SITE CONDITIONS AND DETERMINE METHODS AND EXTENT OF DEWA TERING0.978Note or long string
11. CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING ALL HORIZONTAL AND0.994Note or long string
MATERIALS OR REWORK REQUIRED AS A RESULT OF INADEQUATE OR INSUFFICIENT0.99Note or long string
DRIVEWAYS. SIDEWALKS, RETAINING WALLS. MAILBOXES, TRAFFIC SIGNS. ETC.0.971Note or long string
REMOVED OR DAMAGED DURING CONSTRUCTION WITH THE SAME MATERIAL REMOVED0.992Note or long string
EROSION AND SHALL PROVIDE ADDITIONAL SOD, SOD STAKING AND SHALL FILL,0.997Note or long string
CONSIDERED AS LIMITS OF CONSTRUCTION. PERIMETER CLEARING AND GRUBBING0.998Note or long string
48-HOUR NOTICE OF WHEN CONSTRUCTION WILL COMMENCE IN AN AREA IN ORDER0.992Note or long string
TO PERMIT FIELD LOCA TION OF UTILITY LINES PRIOR TO CONSTRUCTION. THE0.991Note or long string
BY THIS WORK SHALL BE RESTORED TO A CONDITION EQUAL TO OR BETTER THAN0.992Note or long string
TECHNICAL STANDARDS, FDOT STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE0.999Note or long string
5. TEMPORARY OR PERMANENT STABILIZATION BMPS SHALL BE USED AS SOON AS0.996Note or long string
PRACTICABLE BUT IN NO CASE LESS THAN 14 DAYS, IN PORTIONS OF THE SITE0.992Note or long string
CLASS III, UNLESS OTHERWISE NOTED. DRAINAGE INLET STRUCTURES SHALL BE0.985Note or long string
BMPS TO ASSURE PROPER OPERATION. INSPECTIONS SHALL OCCUR AT A MINIMUM0.997Note or long string
REMOVED AND REPLACED IN ACCORDANCE WITH THE CITY OF TAMPA WASTEWA TER0.994Note or long string
INTERVAL OF ONCE EVERY 7 CALENDAR DAYS AND WITHIN 24 HOURS OF THE END0.993Note or long string
PREPARED AND SUBMITTED BY A LICENSED PROFESSIONAL SURVEYOR AND MAPPER0.993Note or long string
ESTABLISHED STANDARDS SHALL BE APPROVED BY THE CITY TRAFFIC ENGINEER.0.99Note or long string
CONVEYANCES INCLUDING TOPS OF BANKS, TOES OF SLOPES, POND BOTTOMS AND0.988Note or long string
WA TER LEVELS; ELEVA TIONS AND DIMENSIONS OF POND CONTROL STRUCTURES,0.988Note or long string
CONSTRUCTION IN ACCORDANCE WITH CHAPTER 13 OF THE CITY OF TAMPA CODE.0.985Note or long string
APPROVAL BEFORE INSTALLATION MAY RESULT IN REMOVAL AND REPLACEMENT AT0.997Note or long string
8. COMPACTION FOR PIPE BACKFILL SHALL COMPLY WITH AASHTO T-99 (1OO%).0.981Note or long string
CHECKED AND VERIFIED BY THE USER. ANY DISCREPANCIES ARE TO BE BROUGHT0.998Note or long string
2. REFERENCE SURVEY: TOPOGRAPHIC SURVEY PREPARED BY GEORGE F. YOUNG:0.989Note or long string
15. ALL AREAS DISTURBED DURING CONSTRUCTION (EXCEPT LANDSCAPE BEDS).0.99Note or long string
LEVEL, REPAIR AND RE-GRASS ALL ERODED OR DEAD AREAS AS NECESSARY, TO0.995Note or long string
2. TEMPORARY STOCKPILES SHALL NOT BE LOCATED ADJACENT TO STORM SEWER0.994Note or long string
MAY BE REQUIRED. CONTRACTOR SHALL COORDINATE UTILITY RELOCATION WORK0.979Note or long string
KIND OF LANDSCAPING. MAILBOXES. WALK WAYS. DRIVEWAYS. ETC. EACH YARD0.969Note or long string
VEHICLE UNDERCARRIAGE AREAS OR OTHER EFFECTIVE METHODS PRIOR TO SITE0.997Note or long string
ACCORDANCE WITH THE BEST PRACTICES OF THE INDUSTRY AND IN ACCORDANCE0.995Note or long string
CITY OF TAMPA RIGHT-OF-WAY ARE CONSIDERED PRIVATE UTILITIES. PRIVATE0.994Note or long string
CEASED. STABILIZA TION BMPS MAY INCLUDE TEMPORARY SEEDING, PERMANENT0.988Note or long string
OTHER APPURTENANCES WITHIN CONSTRUCTION LIMITS SHALL ALSO BE REMOVED0.997Note or long string
PLUS LOCATIONS. DIMENSIONS AND ELEVA TIONS OF ALL OTHER CONSTRUCTION0.977Note or long string
COMPONENTS WHICH VARY FROM THE DESIGN. TIES TO UNDERGROUND UTILITIES0.999Note or long string
OF THE EXISTING SURVEY DATA AND OF THE PROPOSED SITE IMPROVEMENTS IS0.997Note or long string
ELEVA TIONS SHOWN ON THE DRAWINGS UNLESS ADDITIONAL TESTING SUPPORTS0.985Note or long string
MATERIAL AND/OR LIMESTONE MATERIALS SHALL BE EXCAVATED REGARDLESS IF0.99Note or long string
AREA. CONTRACTOR SHALL NOTIFY THE ENGINEER (AND SWFWMD AND/OR HILLS.0.999Note or long string
BE CONTINUOUSLY FLAGGED AND SHALL BE RESET IMMEDIA TELY BY A FLORIDA0.975Note or long string
BOX IN THE LINEAR COST OF PIPE. THE CONTRACTOR SHALL COMPLY WITH THE0.982Note or long string
COVERAGE UNDER THE FDEP GENERIC PERMIT FOR THE DISCHARGE OF PRODUCED0.999Note or long string
OPERATIONS AT THE INTERSECTION OF WOODMERE AND LOIS DURING THE ROAD0.99Note or long string
WITHIN THE PROJECT AREA AND REPLACE ALL PAVEMENT, STABILIZED EARTH.0.989Note or long string
MANAGEMENT PRACTICES (BMPS), SHALL BE UTILIZED AS SILT BARRIERS AND0.993Note or long string
2. WHEN IN CONFLICT, UTILITY POLES, GAS LINES, UNDERGROUND ELECTRIC0.985Note or long string
DOWNSTREAM WA TERS, INCLUDING DITCHES, STORM SEWERS, WA TER BODIES.0.977Note or long string
WETLAND AREAS, ADJACENT PROPERTIES OR RIGHTS-OF-WAY. THESE BARRIERS0.993Note or long string
LINES & GRADES SHOWN HEREIN UPON FINAL ACCEPTANCE. SOD SHALL BE 95%0.988Note or long string
LOCATION OF UNDERGROUND LINES. TECO GAS TO RELOCATE ANY CONFLICTING0.997Note or long string
INLETS, DITCHES, UNDISTURBED WETLANDS OR SURFACE WA TER AREAS WHERE0.991Note or long string
SEDIMENTA TION FROM STOCKPILES MAY CAUSE DAMAGE. ADDITIONALLY, SILT0.991Note or long string
ON-SITE AND SHALL BE RESPONSIBLE TO ADHERE TO ALL PERMIT CONDITIONS0.996Note or long string
RUNOFF FROM EXPOSED SOILS, STORE RUNOFF AND/OR SEDIMENT ON-SITE, OR0.998Note or long string
OTHERWISE LIMIT RUNOFF AND THE DISCHARGE OF POLLUTANTS FROM EXPOSED0.998Note or long string
WITNESSED OR PERFORMED BY A CERTIFIED ARBORIST. ROOT PRUNING MAY BE0.984Note or long string
SPECIFICATIONS. REFER TO THE BOUNDARY AND/OR TOPOGRAPHIC SURVEY FOR0.993Note or long string
12. THE CONTRACTOR SHALL INCLUDE THE COST OF SHEETING AND/OR TRENCH0.999Note or long string
AVAILABLE AT THE TIME OF THE PREPARATION OF THESE PLANS BUT DO NOT0.998Note or long string
APPLICABLE, INCLUDING THE INITIAL ROLLING TO FULLY SEAT SOD TO THE0.989Note or long string
AS ANY AFFECTED CITY AND COUNTY DEPARTMENTS BY PROVIDING A MINIMUM0.993Note or long string
10. THE CONTRACTOR SHALL MAINTAIN COPIES OF ALL APPLICABLE PERMITS0.985Note or long string
OF DUST CONTROL SHALL BE EMPLOYED TO PREVENT THE EMANATION OF DUST0.991Note or long string
FROM THE SITE. PERMANENT GRASSING, LANDSCAPING AND OTHER SITE WORK0.997Note or long string
19. SUBSURFACE SHALL BE FREE FROM TROWEL OR MACHINE MARKS. SURFACE0.998Note or long string
WHERE CONSTRUCTION ACTIVITIES HAVE BEEN TEMPORARILY OR PERMANENTLY0.998Note or long string
MATCH PROPOSED GRADE AS REQUIRED. COST TO BE INCLUDED IN OTHER PAY0.983Note or long string
IN RESIDENTIAL YARDS WITHIN CONSTRUCTION LIMITS AND/OR RESTORE ANY0.998Note or long string
CITY CODE AND THE TRANSPORTATION TECHNICAL MANUAL. DEVIA TION FROM0.991Note or long string
STABILIZATION HAS BEEN ACHIEVED, SILT BARRIERS SHALL BE COMPLETELY0.998Note or long string
FROM SANITARY AND STORM SEWER PIPES; TIES TO SANITARY SEWER LINES,0.993Note or long string
MANUFACTURED ITEMS TO THE ENGINEER FOR APPROVAL. FAILURE TO OBTAIN0.998Note or long string
1. NO EXCAVATION SHALL EXTEND BELOW THE PERMITTED DESIGN DEPTHS OR0.991Note or long string
HOWEVER. USE OF THIS ELECTRONIC FORMAT IS AT THE CONTRACTOR'S SOLE0.98Note or long string
RESPONSIBILITY AS ALL WORK MUST BE IN ACCORDANCE WITH THE CONTRACT0.988Note or long string
SUCH OVER-EXCAVA TION AND NO LOWER SEMI-CONFINING UNIT CLAYEY SOIL0.98Note or long string
CONTRACTOR MEANS AND METHODS. CONSTRUCTION OPTIONS INCLUDE BUT NOT0.997Note or long string
PURPORT TO BE ABSOLUTELY CORRECT. THE CONTRACTOR SHALL VERIFY THE0.991Note or long string
AND OTHER FEATURES AFFECTING HIS WORK PRIOR TO CONSTRUCTION. GAS.0.983Note or long string
SHALL BE SODDED TO PROVIDE A RESTORATION THAT IS FULLY GRASSED AT0.997Note or long string
6. PRIOR TO ANY CONSTRUCTION, CONTACT TAMPA ELECTRIC COMPANY (PH:0.997Note or long string
WEED-FREE ARGENTINE BAHIA UNLESS OTHERWISE INDICATED OR OTHERWISE0.99Note or long string
STANDARDS AND STANDARD DETAILS. CAST-IN-PLACE OR PRECAST JUNCTION0.997Note or long string
SEALED RECORD SURVEY AND ONE COPY OF THE SURVEY IN AUTOCAD (.DWG)0.984Note or long string
LIMESTONE MATERIALS ARE ENCOUNTERED ABOVE THE PERMITTED DEPTHS OR0.998Note or long string
AND UNIQUE FEATURES INCLUDING BUT NOT LIMITED TO BRICK PAVERS FOR0.986Note or long string
FEATURES, TREES, ETC. CONTRACTOR SHALL PERFORM RESTORATION OF ANY0.994Note or long string
PROVIDED FOR CONTROL OF GROUND OR SURFACE WATER OR FOR ADDITIONAL0.986Note or long string
LIMITED TO INCLUDE SHEET PILING, SLOPED OPEN CUT, AND TRENCH BOX.0.997Note or long string
SUBSURFACE PIPING HAS NOT BEEN LOCATED. ENGINEER OF RECORD SHOWS0.991Note or long string
SHALL BE INSTALLED PRIOR TO COMMENCING CONSTRUCTION AND SHALL BE0.996Note or long string
WIDTH NECESSARY FOR SUCH WORK. PERIMETER BARRIERS SHALL BE FULLY0.995Note or long string
MAINTAINED IN ACCORDANCE WITH FDOT SPECIFICATION SECTION 57O, AS0.989Note or long string
CLEARING AND GRUBBING OPERATIONS WITHIN THE CONSTRUCTION LIMITS.0.979Note or long string
AS A RESULT OF THE CONTRACTOR'S ACTIONS SHALL BE REPAIRED AT THE0.993Note or long string
THE FDOT UTILITY ACCOMMODA TION MANUAL OR IN ACCORDANCE WITH THE0.991Note or long string
DAMAGED SYSTEMS DURING CONSTRUCTION BACK TO EXISTING CONDITIONS.0.998Note or long string
SUFFICIENT TO DETERMINE DIRECTION OF DRAINAGE AND ELEVA TIONS OF0.993Note or long string
9. ONCE CONSTRUCTION IS COMPLETED AND FINISHED GRADING AND FINAL0.999Note or long string
FORMAT SHALL BE PROVIDED. A RECORD SURVEY DEPICTING THE AS-BUILT0.992Note or long string
BY THE OWNER, ENGINEER AND THE APPROPRIATE REGULATORY AUTHORITY.0.995Note or long string
AVAILABLE AND MAY BE USED FOR CONVENIENCE IN LAYOUT OF THE WORK.0.989Note or long string
TREE REMOVAL NOTICING. CONTRACTOR RESPONSIBLE FOR ANY PERMITTING0.997Note or long string
'ADA'STANDARDS. SIDEWALK CROSS SLOPES AND DRIVEWAY CROSSINGS FOR0.987Note or long string
GROUNDWA TER FROM ANY NON-CONTAMINATED SITE ACTIVITY PURSUANT TO0.989Note or long string
AND OTHER FEATURES ARE SHOWN ACCORDING TO THE BEST INFORMA TION0.99Note or long string
PLANS, PROPER CONNECTIONS SHALL BE MADE AT THE DIRECTION OF THE0.987Note or long string
EXCAVA TION AREA, SHALL BE INCLUDED IN THE VARIOUS ITEMS OF THE0.99Note or long string
NECESSARY FOR TREE TRIMMING AND ROOT PRUNING FOR BOTH GRAND AND0.992Note or long string
DOCUMENTS FOR THE PROJECT. THE ACCURACY OF THESE FILES SHALL BE0.989Note or long string
DRIVEWAYS AND WALKWAYS, MAILBOXES, LANDSCAPE PLANTERS AND OTHER0.994Note or long string
LOCATIONS AS APPROXIMATE FROM INFORMA TION PROVIDED BY OTHERS.0.984Note or long string
PLACED IN LOCATIONS AS REQUIRED TO KEEP SEDIMENT FROM REACHING0.99Note or long string
REQUIRED TO MATCH EXISTING SOD TYPE AND SHALL BE INSTALLED AND0.997Note or long string
BOXES OR MANHOLES SHALL BE CONSTRUCTED IN ACCORDANCE WITH FDOT0.998Note or long string
REMOVED TO THE SATISFACTION OF THE ENGINEER AND PRIOR TO FINAL0.992Note or long string
AND/OR BYPASSING OF FLOWS NECESSARY AND SHALL INCLUDE COSTS OF0.997Note or long string
WLTH COARSE AGGREGA TE PIPE BEDDING WRAPPED IN FIL TER FABRIC.0.943Note or long string
REMAIN FOR LONGER THAN 24 HOURS TO CONTAIN MATERIALS WITHIN A0.984Note or long string
PLANS. HOWEVER, THIS IN NO WAY RELIEVES THE CONTRACTOR OF HIS0.978Note or long string
RETENTION/DETENTION AREAS, MITIGATION AREAS AND DITCH/CHANNEL0.991Note or long string
9. LIMITS OF DISTURBED OPEN CUT AREAS MAY VARY DEPENDENT UPON0.999Note or long string
CONSTRUCTION PLANS AND SPECS ASSUME A SLOPED OPEN CUT TRENCH.0.991Note or long string
SHOWN ON THE PLANS AND TO TOLERANCES STATED HEREIN OR IN THE0.988Note or long string
STORM PIPE TRENCH BACKFILLING SHALL CONFORM TO FDOT STANDARD0.998Note or long string
7. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS ON ALL PRECAST AND0.993Note or long string
CONTRACTOR SHALL FIELD-VERIFY SIDEWALK FORM BOARDS PRIOR TO0.998Note or long string
VERTICAL CONTROL MARKERS. RIGHT-OF-WAY AND PROPERTY CORNERS0.977Note or long string
REQUIREMENTS OF THE FLORIDA TRENCH SAFETY ACT, CHAPTER 553.0.996Note or long string
INCLUDING, BUT NOT LIMITED TO, LOCA TION AND FINISHED GRAL0.987Note or long string
DRIVEWAYS, SIDEWALKS, RETAINING WALLS, MAILBOXES, TRAFFIC0.982Note or long string
18. THE CONTRACTOR SHALL CONTACT THE ENGINEER'S OFFICE IN0.996Note or long string
VALVES, BENDS, SERVICE CONNECTIONS; WATER LINE ELEVA TION0.98Note or long string
ATION OPERATIONS SHALL IMMEDIA TELY CEASE IN THE GENERAL0.984Note or long string
DUNDWATER DEWATERING ACTIVITIES, CONTRACTOR SHALL OBTAIN0.986Note or long string
STAFF TO ADJUST SIGNAL TIMING AS NEEDED TO MAINTAIN PRC0.99Note or long string
KIND OF LANDSCAPING, MAILBOXES, WALK WAYS, DRIVEWAYS, E0.982Note or long string
WITH THE ENGINEER FOR MAKING ANY AND ALL REQUIRED INTEI0.982Note or long string
19. SUBSURFACE SHALL BE FREE FROM TROWEL OR MACHINE MAI0.99Note or long string
22. UPON FINAL PAVEMENT RESTORATION, RE-STRIPE ROAD CEN0.994Note or long string
WATER LEVELS; ELEVA TIONS AND DIMENSIONS OF POND CONTRC0.98Note or long string
6. CONTRACTOR RESPONSIBLE FOR SUPPL YING ALL MOT PLANS.0.981Note or long string
PASSING IN THE BID. NO ADDITIONAL COMPENSATION SHALL BE0.997Note or long string
WITHIN THE PROJECT AREA AND REPLACE ALL PAVEMENT, STAE0.995Note or long string
BY THE RESPECTIVE UTILITY OWNERS AT THEIR OWN EXPENSE.0.989Note or long string
NSTRUCTION SCHEDULE WITH ALL UTILITY COMPANIES AS WELL0.991Note or long string
VARIATIONS SHALL NOT EXCEED 1/4 INCH UNDER TEN-FOOT (10.985Note or long string
VIDE THIS SERVICE WLTHOUT CHARGING A FEE TO THE CLTY'S0.925Note or long string
CONVEYANCES INCLUDING TOPS OF BANKS, TOES OF SLOPES, F0.989Note or long string
PLUS LOCATIONS, DIMENSIONS AND ELEVATIONS OF ALL OTHER0.995Note or long string
ANY LOWER SEMI-CONFINING UNIT CLAYEY SOIL MATERIALS OR0.986Note or long string
DRK REQUIRED AS A RESULT OF INADEQUATE OR INSUFFICIENT0.988Note or long string
LICENSED LAND SURVEYOR IF ANY SHOULD BECOME DISTURBED.0.988Note or long string
THESE DRAWINGS.IT SHALL BE THE CONTRACTOR'S RESPONSIE0.997Note or long string
JNSIDLLTORLOCATINGTTTLIR OTLTTILSPRTORTO CONSTROCTTON0.848Note or long string
2OCONTRACTOR TO PROTECT EXISTING PRIVATE FENCES DURIN0.943Note or long string
PRECAST AND CONSTRUCTED IN ACCORDANCE WITH THE CITY C0.993Note or long string
RELOCATION TIMES IN THE PROJECT CONSTRUCTION SCHEDULE0.997Note or long string
FOR POTABLE AND RECLAIMED WATER LINES SHALL BE ISSUED0.988Note or long string
CES WITHIN CONSTRUCTION LIMITS SHALL ALSO BE REMOVED.0.998Note or long string
ALLY SHOWN TO BE REMOVED SHALL BE PROTECTED WITH TREE0.993Note or long string
CLEANOUTS AND SERVICE CONNECTIONS; MANHOLE RIM AND IN0.986Invert or rim value
OE AT THE CONTRACTOR'S EXPENSE UNLESS ON—SLTE LUSE IS0.893Note or long string
OR DAMAGED OR AS OTHERWISE DIRECTED BY THE ENGINEER.0.998Note or long string
TY OWNER(S) AND SHALL ENDEAVOR TO COORDINATE HIS OWN0.996Note or long string
E DURATION OF CONSTRUCTION.TREE LIMB OR ROOT PRUNING0.991Note or long string
FOR HILLSBOROUGH COUNTY IF DETERMINED ONE IS NEEDED.0.997Note or long string
APPLICABLE) PRIOR TO ANY FURTHER EXCAVATION IN THESE0.988Note or long string
EXISTING UNLESS SPECIFICALLY EXEMPTED BY THE PLANS.0.997Existing condition callout
ONS AND DE TERMINE METHODS AND EXTENT OF DEWATERING0.932Note or long string
TER MAIN, WATER SERVICES, SEWER LATERALS AND OTHER0.986Note or long string
CATION OF UTILITY LINES PRIOR TO CONSTRUCTION. THE0.996Note or long string
TER-RELATED WORK WITH THE WATER DEPARTMENT AND ITS0.992Note or long string
ONS AND DETERMINE METHODS AND EXTENT OF DEWATERING0.989Note or long string
ES AFFECTING HIS WORK PRIOR TO CONSTRUCTION. GAS,0.998Note or long string
ROLOE GROUND OR SUREACE WA TER OR FOR ADDLTIONAL0.889Note or long string
1 ANY NON-CONTAMINATED SITE ACTIVITY PURSUANT TO0.979Note or long string
UTILITY POLES, GAS LINES, UNDERGROUND ELECTRIC,0.995Note or long string
ETC. DAMAGED DURING DEMOLITION OR CONSTRUCTION.0.988Note or long string
ES ARE SHOWN ACCORDING TO THE BEST INFORMATION0.991Note or long string
1. STAKED OR FLOATING SILT SCREENS, HAY BALES,0.996Note or long string
ETC. AFFECTING HIS WORK PRIOR TO CONSTRUCTION.0.996Note or long string
3. OFF-SITE VEHICLE TRACKING OF SEDIMENT SHALI0.986Note or long string
WA TERING, APPLICA TION OF CALCIUM CHLORIDE OR0.976Note or long string
SPECIFICA TIONS 125. BOX CULVERT BACKFILLING V0.985Note or long string
ROXIMATE FROM INFORMATION PROVIDED BY OTHERS.0.994Note or long string
S. VERIZON TO RELOCATE ANY CONFLICTING LINES.0.992Note or long string
SEEDING, MULCHING, GEOTEXTILES, SOD STABILIZA0.99Note or long string
SEEDING. MULCHING. GFOTEXTILES. SOD STABILIZA0.941Note or long string
7) FOR EXACT LOCA TION OF UNDERGROUND LINES.0.976Note or long string
INSTALLATION OF SILT BARRIERS PROVIDING THAT0.993Note or long string
INLETS, DITCHES, UNDISTURBED WETLANDS OR SUF0.974Note or long string
NT, NATURAL RESOURCES DIVISION, AND SHALL BE0.99Note or long string
2. PRICE FOR ALL REMOVAL, AS SHOWN ON THE PL0.997Note or long string
7. PRIOR TO CONSTRUCTION CONTRACTOR TO RECOI0.984Note or long string
MANHOLES AND REFER TO THE SURVEY BASE LINE.0.998Note or long string
PLACED IN LOCATIONS AS REQUIRED TO KEEP SEL0.989Note or long string
DOWNSTREAM WATERS, INCLUDING DITCHES, STORM0.986Note or long string
SHALL BE INSTALLED PRIOR TO COMMENCING CON.0.984Note or long string
ALONG THE LIMITS OE CONSTRUCTION IS ALLOWED0.965Note or long string
BARRIERS SHALL CONTINUOUSLY AND FULLY ENCIA0.995Note or long string
FOR IMMEDIATE CONSTRUCTION SHALL BE CLEAREL0.995Note or long string
CEASED. STABILIZATION BMPS MAY INCLUDE TEMA0.985Note or long string
G DRIVES AND WALKS ARE NOT INDICATED ON THE0.996Note or long string
PUCTED IN ACCORDANCE WITH CHAPTER 25 OF THE0.991Note or long string
CONTROLS, SHALL BE DONE IN A TIMELY MANNER,0.995Note or long string
CHAPTER 13 TECHNICAL MANUAL SPECIFICATIONS.0.999Note or long string
EXCAVATION AREA, SHALL BE INCLUDED IN THE V0.994Note or long string
6. CONTRACTOR RESPONSIBLE FOR SUPPLYING ALL0.998Note or long string
STORM PIPE TRENCH BACKFILLING SHALL CONFORN0.991Note or long string
CITY OF TAMPA BENCHMARK HV-O2 OO72, HAVING0.966Note or long string
SUNSHINE(1-800-432-4770) AT LEAST 72 HOURS0.981Note or long string
CONSIDERED AS LIMITS OF CONSTRUCTION.PERIM0.994Note or long string
SEDIMENTATION FROM STOCKPILES MAY CAUSE DA0.986Note or long string
REMAIN FOR LONGER THAN 24 HOURS TO CONTAII0.991Note or long string
S, AND THE LATEST EDITION OF CITY OF TAMPA0.995Note or long string
SHALL BE INCORPORATED AS SOON AS POSSIBLE.0.998Note or long string
COST SHALL BE INCLUDED IN OTHER PAY ITEMS.0.995Note or long string
BMPS TO ASSURE PROPER OPERATION. INSPECTIC0.979Note or long string
INTERVAL OF ONCE EVERY 7 CALENDAR DAYS ANL0.988Note or long string
AND DOCUMENT ALL UNIQUE AND SPECIAL FEATUA0.993Note or long string
WITH COARSE AGGREGATE PIPE BEDDING WRAPPED0.998Note or long string
SUBGRADE AND ELIMINATE IRREGULAR SURFACE.0.998Note or long string
ORDANCE WITH THE CITY OF TAMPA WASTEWATER0.993Note or long string
JSER. ANY DISCREPANCIES ARE TO BE BROUGHT0.993Note or long string
EER PRIOR TO THE USE OF THIS INFORMATION.0.997Note or long string
ID PEDESTRIAN WALKWAYS SHALL MEET MINIMUM0.994Note or long string
VSIBLE FOR MAINTAINING ALL HORIZONTAL AND0.992Note or long string
CONTRACTOR MEANS AND METHODS. CONSTRUCTIC0.995Note or long string
CONSTRUCTION PLANS AND SPECS ASSUME A SLC0.99Note or long string
PHIC SURVEY PREPARED BY GEORGE F. YOUNG;0.996Note or long string
OF A STORM THAT IS 1/4-INCH OR GREA TER.0.978Note or long string
WETLAND AREAS,ADJACENTPROPERTIESOR RTGH0.966Note or long string
TECO TO RELOCATE ANY CONFLICTING LINES.0.992Note or long string
PRACTICABLE BUTIN NO CASE LESSTHANT4 DA0.918Note or long string
OF A STORM THAT IS 1/4-INCH OR GREATER.0.995Note or long string
VGINEER FOR APPROVAL. FAILURE TO OBTAIN0.987Note or long string
SHALL BE RESET IMMEDIATELY BY A FLORIDA0.989Note or long string
ABILIZATION. SWALE SODDING. VEGETATIVE0.963Note or long string
ABILIZATION, SWALE SODDING, VEGETATIVE0.993Note or long string
RELOCATED AS DIRECTED BY THE ENGINEER.0.995Note or long string
VIC FORMAT IS AT THE CONTRACTOR'S SOLE0.991Note or long string
IST BE IN ACCORDANCE WITH THE CONTRACT0.983Note or long string
PRIOR TO ANY CONSTRUCTION ACTIVITIES.0.996Note or long string
10. THE CONTRACTOR SHALL MAINTAIN COI0.992Note or long string
WORK TO AVOID DELAYS IN HIS SCHEDULE.0.995Note or long string
ROADWAY AND TRAFFIC DESIGN STANDARDS.0.993Note or long string
TION TECHNICAL MANUAL. DEVIATION FROM0.989Note or long string
SHALL COMPLY WITH AASHTO T-99 (100%).0.992Note or long string
DR CONVENIENCE IN LAYOUT OF THE WORK.0.991Note or long string
TECO TO RELOCATE ANY CONFLICTING LII0.981Note or long string
STREET CLOSURES IN THE PROJECT AREA.0.943Note or long string
WITH THE PROJECT SPECIFICATIONS, AND0.991Note or long string
N THE PROJECT CONSTRUCTION SCHEDULE.0.995Note or long string
(MONUMENTS, PIPES, ETC.) FOR THE DUP0.971Note or long string
(MONUMENTS. PIPES. ETC.) FOR THE DUF0.947Note or long string
OT STANDARD SPECIFICA TION 125.8.3.40.983Note or long string
DATUM 1983, ADJUSTMENT OF 2011, NAL0.965Note or long string
LLOWED, IF NECESSARY, TO FACILITATE0.99Note or long string
LOCATION OF UNDERGROUND LINES. VERI0.997Note or long string
HOWEVER, USE OF THIS ELECTRONIC FOR0.995Note or long string
'ADA' STANDARDS. SIDEWALK CROSS SLO0.986Note or long string
VERTICAL CONTROL MARKERS, RIGHT-OF-0.989Note or long string
ALL BE WATER TIGHT. BOX CULVERT AND0.994Note or long string
AN ELEVA TION OF 13.855', NAVD 88.0.966Note or long string

The sheet as continuous text, in the order a person would read it. Note columns become prose, printed tables stay tables.

GENERAL NOTES

  1. ELEVATIONS SHOWN HEREON ARE BASED ON THE NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD88) AND UTILIZE CITY OF TAMPA BENCHMARK HV-02 0072, HAVING AN ELEVATION OF 13.855', NAVD 88.
  2. REFERENCE SURVEY: TOPOGRAPHIC SURVEY PREPARED BY GEORGE F. YOUNG; INC. DATED FEBRUARY 8, 2023.
  3. BEARINGS AND COORDINATES SHOWN HEREON ARE BASED ON THE FLORIDA STATE PLANE COORDINATE SYSTEM, WEST ZONE AS REFERENCED TO THE NORTH AMERICAN DATUM 1983, ADJUSTMENT OF 2011, NAD83(2011) AND ARE SHOWN IN US SURVEY FEET.
  4. STATIONS AND OFFSETS GIVEN ARE TO THE CENTER LINE OF THE INLETS AND MANHOLES AND REFER TO THE SURVEY BASE LINE.
  5. THE CONTRACTOR SHALL CALL SUNSHINE (1-800-432-4770) AT LEAST 72 HOURS PRIOR TO ANY CONSTRUCTION ACTIVITIES.
  6. PRIOR TO ANY CONSTRUCTION, CONTACT TAMPA ELECTRIC COMPANY (PH: 813-228-4111 OR 813-275-3037) FOR EXACT LOCATION OF UNDERGROUND LINES. TECO TO RELOCATE ANY CONFLICTING LINES.
  7. PRIOR TO ANY CONSTRUCTION, CONTACT TECO GAS (813-275-3743) FOR EXACT LOCATION OF UNDERGROUND LINES. TECO GAS TO RELOCATE ANY CONFLICTING LINES.
  8. PRIOR TO ANY CONSTRUCTION, CONTACT VERIZON (813-978-2164) FOR EXACT LOCATION OF UNDERGROUND LINES. VERIZON TO RELOCATE ANY CONFLICTING LINES.
  9. THE SOLID WASTE DEPARTMENT (813-348-1146) IS TO BE NOTIFIED PRIOR TO ANY STREET CLOSURES IN THE PROJECT AREA.
  10. THE CONTRACTOR SHALL MAINTAIN COPIES OF ALL APPLICABLE PERMITS ON-SITE AND SHALL BE RESPONSIBLE TO ADHERE TO ALL PERMIT CONDITIONS DURING CONSTRUCTION.
  11. ALL IMPROVEMENTS WITHIN PUBLIC RIGHTS-OF-WAY SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE BEST PRACTICES OF THE INDUSTRY AND IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS, AND THE LATEST EDITION OF CITY OF TAMPA TECHNICAL STANDARDS, FDOT STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION, THE FDOT ROADWAY AND TRAFFIC DESIGN STANDARD INDEXES, AND THE FDOT UTILITY ACCOMMODATION MANUAL OR IN ACCORDANCE WITH THE REQUIREMENTS OF THE STATE OR LOCAL AUTHORITY HAVING JURISDICTION OVER THE RIGHT-OF-WAY, AS APPLICABLE.

<b>CONSTRUCTION NOTES:</b>

  1. WHERE CONNECTIONS TO EXISTING DRIVES AND WALKS ARE NOT INDICATED ON THE PLANS, PROPER CONNECTIONS SHALL BE MADE AT THE DIRECTION OF THE ENGINEER.
  2. STREET SIGNS, STREET MARKERS AND R-O-W MARKERS SHALL BE REMOVED AND RELOCATED AS DIRECTED BY THE ENGINEER.
  3. CONTRACTOR SHALL RAISE OR LOWER EXISTING MANHOLE FRAME AND COVER TO MATCH PROPOSED GRADE AS REQUIRED. COST TO BE INCLUDED IN OTHER PAY ITEMS.
  4. SEWER SERVICE LATERALS FOUND TO BE IN CONFLICT WITH THE WORK SHALL BE REMOVED AND REPLACED IN ACCORDANCE WITH THE CITY OF TAMPA WASTEWATER DEPARTMENT REQUIREMENTS.
  5. DRIVEWAYS SHALL BE RECONSTRUCTED IN ACCORDANCE WITH CHAPTER 25 OF THE CITY CODE AND THE TRANSPORTATION TECHNICAL MANUAL. DEVIATION FROM ESTABLISHED STANDARDS SHALL BE APPROVED BY THE CITY TRAFFIC ENGINEER.
  6. THE CONTRACTOR SHALL PROTECT ALL TREES IN THE VICINITY OF THE PROPOSED CONSTRUCTION IN ACCORDANCE WITH CHAPTER 13 OF THE CITY OF TAMPA CODE. NO TREES SHALL BE PRUNED WITHOUT PRIOR APPROVAL FROM THE CITY OF TAMPA PARKS & RECREATION DEPARTMENT, NATURAL RESOURCES DIVISION, AND SHALL BE WITNESSED OR PERFORMED BY A CERTIFIED ARBORIST. ROOT PRUNING MAY BE REQUIRED AT CERTAIN LOCATIONS AND SHALL BE COMPLETED IN ACCORDANCE WITH CHAPTER 13 TECHNICAL MANUAL SPECIFICATIONS.
  7. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS ON ALL PRECAST AND MANUFACTURED ITEMS TO THE ENGINEER FOR APPROVAL. FAILURE TO OBTAIN APPROVAL BEFORE INSTALLATION MAY RESULT IN REMOVAL AND REPLACEMENT AT CONTRACTOR'S EXPENSE.
  8. COMPACTION FOR PIPE BACKFILL SHALL COMPLY WITH AASHTO T-99 (100%).
  9. THE CONTRACTOR SHALL PERFORM ALL CONSTRUCTION BY THE LINES AND GRADES SHOWN ON THE PLANS AND TO TOLERANCES STATED HEREIN OR IN THE SPECIFICATIONS. REFER TO THE BOUNDARY AND/OR TOPOGRAPHIC SURVEY FOR ADDITIONAL INFORMATION ON EXISTING CONDITIONS. AN ELECTRONIC CADD DRAWING OF THE EXISTING SURVEY DATA AND OF THE PROPOSED SITE IMPROVEMENTS IS AVAILABLE AND MAY BE USED FOR CONVENIENCE IN LAYOUT OF THE WORK. HOWEVER, USE OF THIS ELECTRONIC FORMAT IS AT THE CONTRACTOR'S SOLE RESPONSIBILITY AS ALL WORK MUST BE IN ACCORDANCE WITH THE CONTRACT DOCUMENTS FOR THE PROJECT. THE ACCURACY OF THESE FILES SHALL BE CHECKED AND VERIFIED BY THE USER. ANY DISCREPANCIES ARE TO BE Brought TO THE ATTENTION OF THE ENGINEER PRIOR TO THE USE OF THIS INFORMATION.
  10. ALL GRADING OF SIDEWALKS AND PEDESTRIAN WALKWAYS SHALL MEET MINIMUM 'ADA' STANDARDS. SIDEWALK CROSS SLOPES AND DRIVEWAY CROSSINGS FOR SIDEWALKS TO BE 2.0% MAX. SLOPE. ALL SIDEWALK RUNNING SLOPES SHALL NOT EXCEED 5% WITHOUT USE OF PROPER RAMPS FOR FDOT OR FLORIDA BUILDING CODE. CONTRACTOR SHALL FIELD-VERIFY SIDEWALK FORM BOARDS PRIOR TO CONSTRUCTING WALKWAYS.
  11. CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING ALL HORIZONTAL AND VERTICAL CONTROL MARKERS, RIGHT-OF-WAY AND PROPERTY CORNERS (MONUMENTS, PIPES, ETC.) FOR THE DURATION OF CONSTRUCTION. MARKERS SHALL BE CONTINUOUSLY FLAGGED AND SHALL BE RESET IMMEDIATELY BY A FLORIDA LICENSED LAND SURVEYOR IF ANY SHOULD BECOME DISTURBED.
  12. THE CONTRACTOR SHALL INCLUDE THE COST OF SHEETING AND/OR TRENCH BOX IN THE LINEAR COST OF PIPE. THE CONTRACTOR SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA TRENCH SAFETY ACT, CHAPTER 553.
  13. UTILIZE A TRAFFIC SIGNAL SPECIALTY SUBCONTRACTOR TO HANDLE ALL TRAFFIC SIGNAL WORK. COORDINATE WITH THE CITY OF TAMPA'S SIGNAL MAINTENANCE SHOP STAFF TO ADJUST SIGNAL TIMING AS NEEDED TO MAINTAIN PROPER TRAFFIC SIGNAL OPERATIONS AT THE INTERSECTION OF WOODMERE AND LOIS DURING THE ROAD CLOSURE.
  14. THE CONTRACTOR SHALL ENDEAVOR TO PROTECT ALL ADJACENT IMPROVEMENTS WITHIN THE PROJECT AREA AND REPLACE ALL PAVEMENT, STABILIZED EARTH, DRIVEWAYS, SIDEWALKS, RETAINING WALLS, MAILBOXES, TRAFFIC SIGNS, ETC. REMOVED OR DAMAGED DURING CONSTRUCTION WITH THE SAME MATERIAL REMOVED OR DAMAGED OR AS OTHERWISE DIRECTED BY THE ENGINEER.
  15. ALL AREAS DISTURBED DURING CONSTRUCTION (EXCEPT LANDSCAPE BEDS), SHALL BE SODDED TO PROVIDE A RESTORATION THAT IS FULLY GRASSED AT SUBSTANTIAL COMPLETION. CONTRACTOR IS RESPONSIBLE FOR CONTROLLING SITE EROSION AND SHALL PROVIDE ADDITIONAL SOD, SOD STAKING AND SHALL FILL, LEVEL, REPAIR AND RE-GRASS ALL ERODED OR DEAD AREAS AS NECESSARY, TO ACHIEVE AN EROSION-FREE RESTORATION AREA (FREE FROM RUTTING, ETC.) TO THE LINES & GRADES SHOWN HEREIN UPON FINAL ACCEPTANCE. SOD SHALL BE 95% WEED-FREE ARGENTINE BAHIA UNLESS OTHERWISE INDICATED OR OTHERWISE REQUIRED TO MATCH EXISTING SOD TYPE AND SHALL BE INSTALLED AND MAINTAINED IN ACCORDANCE WITH FDOT SPECIFICATION SECTION 570, AS APPLICABLE, INCLUDING THE INITIAL ROLLING TO FULLY SEAT SOD TO THE SUBGRADE AND ELIMINATE IRREGULAR SURFACE.
  16. REPAIR AND REPLACEMENT OF ALL PRIVATE AND PUBLIC PROPERTY AFFECTED BY THIS WORK SHALL BE RESTORED TO A CONDITION EQUAL TO OR BETTER THAN EXISTING UNLESS SPECIFICALLY EXEMPTED BY THE PLANS.
  17. CONTRACTOR SHALL RESTORE ALL NEIGHBORING RESIDENTIAL YARDS WITH LIKE KIND OF LANDSCAPING, MAILBOXES, WALK WAYS, DRIVEWAYS, ETC. EACH YARD SHALL BE RESTORED TO EXISTING CONDITIONS UP TO AND INCLUDING FROM BACK OF CURB TO RIGHT OF WAY LINE.
  18. THE CONTRACTOR SHALL CONTACT THE ENGINEER'S OFFICE IMMEDIATELY ON ANY CONFLICTS ARISING DURING CONSTRUCTION OF ANY IMPROVEMENTS SHOWN ON THESE DRAWINGS. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO CONSULT WITH THE ENGINEER FOR MAKING ANY AND ALL REQUIRED INTERPRETATIONS OF THE PLANS. HOWEVER, THIS IN NO WAY RELIEVES THE CONTRACTOR OF HIS RESPONSIBILITY FOR CONSTRUCTING THE PROJECT TO ACCOMPLISH THE INTENT OF THE PLANS.
  19. SUBSURFACE SHALL BE FREE FROM TROWEL OR MACHINE MARKS. SURFACE VARIATIONS SHALL NOT EXCEED 1/4 INCH UNDER TEN-FOOT (10') STRAIGHT EDGE.
  20. CONTRACTOR TO PROTECT EXISTING PRIVATE FENCES DURING CONSTRUCTION OR REPLACE IN LIKE KIND.
  21. ALL STORM SEWER PIPES SHALL BE REINFORCED CONCRETE PIPE (RCP), MINIMUM CLASS III, UNLESS OTHERWISE NOTED. DRAINAGE INLET STRUCTURES SHALL BE PRECAST AND CONSTRUCTED IN ACCORDANCE WITH THE CITY OF TAMPA TECHNICAL STANDARDS AND STANDARD DETAILS. CAST-IN-PLACE OR PRECAST JUNCTION BOXES OR MANHOLES SHALL BE CONSTRUCTED IN ACCORDANCE WITH FDOT ROADWAY AND TRAFFIC DESIGN STANDARDS.
  22. UPON FINAL PAVEMENT RESTORATION, RE-STRIPE ROAD CENTERLINE TO EXISTING. COST SHALL BE INCLUDED IN OTHER PAY ITEMS.
  23. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SUPPLYING A RECORD SURVEY(S) PREPARED AND SUBMITTED BY A LICENSED PROFESSIONAL SURVEYOR AND M映射 including, but not limited to, location and finished grade elevations sufficient to determine direction of drainage and elevations of retention/ detention areas, mitigation areas and ditch/ channel conveyances including tops of banks, toes of slopes, pond bottoms and water levels; elevations and dimensions of pond control structures, spillways, skimmers/ baffles, sums and underdrain; ties to water lines, valves, bends, service connections; water line elevations and clearances from sanitary and storm sewer pipes; ties to sanitary sewer lines, cleanouts and service connections; manhole rim and invert elevations; ties to storm sewer lines and storm structure top and invert elevations; plus locations, dimensions and elevations of all other construction components which vary from the design. Ties to underground utilities SHALL BE DIMENSIONED FROM PERMANENT ABOVE GROUND STRUCTURES (BUILDINGS, WALKS, POLES, MANHOLES, VALVE BOXES, ETC.) FOUR COPIES OF THE SIGNED AND SEALED RECORD SURVEY AND ONE COPY OF THE SURVEY IN AUTOCAD (.DWG) FORMAT SHALL BE PROVIDED. A RECORD SURVEY DEPICTING THE AS-BUILT CONDITION OF ONLY WATER AND SEWER UTILITIES SHALL BE PROVIDED IF THESE UTILITIES ARE TO BE PLACED IN SERVICE PRIOR TO CLOSEOUT OF THE PROJECT.

<b>UTILITIES:</b>

  1. LOCATIONS, ELEVATIONS AND DIMENSIONS OF THE EXISTING UTILITIES, STRUCTURES AND OTHER FEATURES ARE SHOWN ACCORDING TO THE BEST INFORMATION AVAILABLE AT THE TIME OF THE PREPARATION OF THESE PLANS BUT DO NOT PURPORT TO BE ABSOLUTELY CORRECT. THE CONTRACTOR SHALL VERIFY THE LOCATIONS, ELEVATIONS, AND DIMENSIONS, OF ALL EXISTING UTILITIES, STRUCTURE, AND OTHER FEATURES AFFECTING HIS WORK PRIOR TO CONSTRUCTION. GAS, COMMUNICATION, WATER MAIN, WATER SERVICES, SEWER LATERALS AND OTHER SUBSURFACE PIPING HAS NOT BEEN LOCATED. ENGINEER OF RECORD SHOWS LOCATIONS AS APPROXIMATE FROM INFORMATION PROVIDED BY OTHERS.
  2. WHEN IN CONFLICT, UTILITY POLES, GAS LINES, UNDERGROUND ELECTRIC, TELEPHONE AND OTHER COMMUNICATION CABLES AND CONDUIT WILL BE RELOCATED BY THE RESPECTIVE UTILITY OWNERS AT THEIR OWN EXPENSE.
  3. CONTRACTOR IS TO EXERCISE CAUTION WHEN OPERATING NEAR OR ADJACENT TO EXISTING PUBLIC AND PRIVATE UTILITIES. THE CONTRACTOR SHALL VERIFY THE LOCATIONS, ELEVATIONS AND DIMENSIONS OF ALL EXISTING UTILITIES, STRUCTURES, ETC. AFFECTING HIS WORK PRIOR TO CONSTRUCTION.
  4. IF UTILITY FIELD LOCATION MARKINGS ARE REQUIRED, THE CONTRACTOR SHALL COORDINATE HIS CONSTRUCTION SCHEDULE WITH ALL UTILITY COMPANIES AS WELL AS ANY AFFECTED CITY AND COUNTY DEPARTMENTS BY PROVIDING A MINIMUM 48-HOUR NOTICE OF WHEN CONSTRUCTION WILL COMMENCE IN AN AREA IN ORDER TO PERMIT FIELD LOCATION OF UTILITY LINES PRIOR TO CONSTRUCTION. THE CONTRACTOR IS RESPONSIBLE FOR CONTACTING SUNSHINE 811 FOR THIS PURPOSE BY DIALING 811. FURTHER, THE CONTRACTOR IS CAUTIONED THAT THE SUNSHINE 811 SYSTEM MAY NOT REVEAL ALL ONSITE UTILITIES AND HIS FURTHER INVESTIGATION MAY BE REQUIRED. CONTRACTOR SHALL COORDINATE UTILITY RELOCATION WORK WITH AFFECTED UTILITY OWNER(S) AND SHALL ENDEAVOR TO COORDINATE HIS OWN WORK TO AVOID DELAYS IN HIS SCHEDULE.
  5. ALL UTILITIES SHALL BE KEPT IN OPERATION EXCEPT WITH THE EXPRESS WRITTEN CONSENT OF THE UTILITY OWNER. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PRESERVE EXISTING UTILITIES AND ANY AND ALL DAMAGE TO EXISTING UTILITIES AS A RESULT OF THE CONTRACTOR'S ACTIONS SHALL BE REPAIRED AT THE CONTRACTOR'S EXPENSE.
  6. CITY OWNED UTILITIES WITHIN THE PROJECT LIMITS INCLUDE WATER, WASTEWATER, DRAINAGE AND TRAFFIC SIGNAL CABLES. ALL OTHER UTILITIES PRESENT WITHIN THE CITY OF TAMPA RIGHT-OF-WAY ARE CONSIDERED PRIVATE UTILITIES. PRIVATE UTILITIES ARE RESPONSIBLE FOR LOCATING THEIR UTILITIES PRIOR TO CONSTRUCTION AND, IF REQUIRED, RELOCATED AND/OR TEMPORARILY SUPPORTING THEIR UTILITIES TO ALLOW THE SAFE CONSTRUCTION OF THE WORK UNDER THIS CONTRACT. PRIVATE UTILITIES MUST PROVIDE THIS SERVICE WITHOUT CHARGING A FEE TO THE CITY'S CONTRACTOR/SUBCONTRACTOR.
  7. COORDINATE RELOCATION, OR PROVISION OF TEMPORARY SUPPORT, OF PRIVATE UTILITIES WHEN NOTED ON PLANS "TO BE RELOCATED BY OTHERS". INCLUDE UTILITY RELOCATION TIMES IN THE PROJECT CONSTRUCTION SCHEDULE.
  8. CONTRACTOR TO PROTECT EXISTING IRRIGATION SYSTEMS AND ANY OTHER UTILITIES IN RESIDENTIAL YARDS WITHIN CONSTRUCTION LIMITS AND/OR RESTORE ANY DAMAGED SYSTEMS DURING CONSTRUCTION BACK TO EXISTING CONDITIONS.
  9. RELOCATION PLANS FOR POTABLE AND RECLAIMED WATER LINES SHALL BE ISSUED PRIOR TO COMMENCEMENT OF CONSTRUCTION ACTIVITIES. THE CONTRACTOR SHALL COORDINATE ALL WATER-RELATED WORK WITH THE WATER DEPARTMENT AND ITS DESIGNATED COORDINATOR TO AVOID CONFLICTS AND ENSURE PROPER SEQUENCING OF WORK.

<b>DEMOLITION:</b>

  1. ALL INCIDENTAL PAVING, SIDEWALKS, BOLLARDS, FENCES, HEDGES, BUSHES AND OTHER APPURTENANCES WITHIN CONSTRUCTION LIMITS SHALL ALSO BE REMOVED. TREES NOT SPECIFICALLY SHOWN TO BE REMOVED SHALL BE PROTECTED WITH TREE BARRICADES FOR THE DURATION OF CONSTRUCTION. TREE LIMB OR ROOT PRUNING SHALL BE DONE IN THE PRESENCE OF A CERTIFIED ARBORIST AND IN ACCORDANCE WITH THE CITY TREE PERMIT.
  2. ALL MATERIALS DEMOLISHED OR REMOVED SHALL BE REMOVED FROM THE SITE AND PROPERLY DISPOSED OF AT THE CONTRACTOR'S EXPENSE UNLESS ON-SITE USE IS OTHERWISE APPROVED.
  3. NO OPEN BURNING WILL BE ALLOWED AT THE SITE UNLESS A PLAN IS APPROVED BY THE OWNER, ENGINEER AND THE APPROPRIATE REGULATORY AUTHORITY.
  4. CONTRACTOR SHALL REPAIR, IN KIND, ALL ADJACENT STRUCTURES, PAVEMENTS, ETC. DAMAGED DURING DEMOLITION OR CONSTRUCTION.

<b>ENVIRONMENTAL PROTECTION:</b>

  1. NO EXCAVATION SHALL EXTEND BELOW THE PERMITTED DESIGN DEPTHS OR ELEVATIONS SHOWN ON THE DRAWINGS UNLESS ADDITIONAL TESTING SUPPORTS SUCH OVER-EXCAVATION AND NO LOWER SEMI-CONFINING UNIT CLAYEY SOIL MATERIAL AND/OR LIMESTONE MATERIALS SHALL BE EXCAVATED REGARDLESS IF THESE MATERIALS ARE ENCOUNTERED WITHIN THE PERMITTED EXCAVATION DEPTHS OR ELEVATIONS. IF ANY LOWER SEMI-CONFINING UNIT CLAYEY SOIL MATERIALS OR LIMESTONE MATERIALS ARE ENCOUNTERED ABOVE THE PERMITTED DEPTHS OR ELEVATIONS, EXCAVATION OPERATIONS SHALL IMMEDIATELY CEASE IN THE GENERAL AREA. CONTRACTOR SHALL NOTIFY THE ENGINEER (AND SWFWMD AND/OR HILLS. COUNTY. E.P.C., AS APPLICABLE) PRIOR TO ANY FURTHER EXCAVATION IN THESE AREAS.
  2. CONSTRUCTION SHALL BE CARRIED OUT "IN THE DRY". THE CONTRACTOR SHALL REVIEW SITE CONDITIONS AND DETERMINE METHODS AND EXTENT OF DEWATERING AND/OR BYPASSING OF FLOWS NECESSARY AND SHALL INCLUDE COSTS OF DEWATERING OR BYPASSING IN THE BID. NO ADDITIONAL COMPENSATION SHALL BE PROVIDED FOR CONTROL OF GROUND OR SURFACE WATER OR FOR ADDITIONAL MATERIALS OR REWORK REQUIRED AS A RESULT OF INADEQUATE OR INSUFFICIENT DEWATERING.
  3. PRIOR TO ANY GROUNDWATER DEWATERING ACTIVITIES, CONTRACTOR SHALL OBTAIN COVERAGE UNDER THE FDEP GENERIC PERMIT FOR THE DISCHARGE OF PRODUCED GROUNDWATER FROM ANY NON-CONTAMINATED SITE ACTIVITY PURSUANT TO CHAPTER 62-621.300(2), F.A.C.

<b>EROSION & SEDIMENT CONTROL:</b>

  1. STAKED OR FLOATING SILT SCREENS, HAY BALES, OR OTHER APPROPRIATE BEST MANAGEMENT PRACTICES (BMPS), SHALL BE UTILIZED AS SILT BARRIERS AND PLACED IN LOCATIONS AS REQUIRED TO KEEP SEDIMENT FROM REACHING DOWNSTREAM WATERS, INCLUDING DITCHES, STORM SEWERS, WATER BODIES, WETLAND AREAS, ADJACENT PROPERTIES OR RIGHTS-OF-WAY. THESE BARRIERS SHALL BE INSTALLED PRIOR TO COMMENCING CONSTRUCTION AND SHALL BE CONSIDERED AS LIMITS OF CONSTRUCTION. PERIMETER CLEARING AND GRUBBING ALONG THE LIMITS OF CONSTRUCTION IS ALLOWED, IF NECESSARY, TO FACILITATE INSTALLATION OF SILT BARRIERS PROVIDING THAT DISTURBANCE IS THE MINIMUM WIDTH NECESSARY FOR SUCH WORK. PERIMETER BARRIERS SHALL BE FULLY INSTALLED, INCLUDING BACKFILLING IF NECESSARY, PRIOR TO ANY ADDITIONAL CLEARING AND GRUBBING OPERATIONS WITHIN THE CONSTRUCTION LIMITS.
  2. TEMPORARY STOCKPILES SHALL NOT BE LOCATED ADJACENT TO STORM SEWER INLETS, DITCHES, UNDISTURBED WETLANDS OR SURFACE WATER AREAS WHERE SEDIMENTATION FROM STOCKPILES MAY CAUSE DAMAGE. ADDITIONALLY, SILT BARRIERS SHALL CONTINUOUSLY AND FULLY ENCIRCLE ALL STOCKPILES WHICH WILL REMAIN FOR LONGER THAN 24 HOURS TO CONTAIN MATERIALS WITHIN A REASONABLY CONFINED AREA.
  3. OFF-SITE VEHICLE TRACKING OF SEDIMENT SHALL BE MINIMIZED BY CLEANING VEHICLE UNDERCARRIAGE AREAS OR OTHER EFFECTIVE METHODS PRIOR TO SITE DEPARTURE.
  4. ALL FUGITIVE DUST SHALL BE CONTROLLED ON SITE. ONLY AREAS SCHEDULED FOR IMMEDIATE CONSTRUCTION SHALL BE CLEARED OR SEDIMENTED ON-SITE, OR OTHERWISE LIMIT RUNOFF AND THE DISCHARGE OF POLLUTANTS FROM EXPOSED AREAS OF THE SITE.
  5. TEMPORARY OR PERMANENT STABILIZATION BMPS SHALL BE USED AS SOON AS PRACTICABLE BUT IN NO CASE LESS THAN 14 DAYS, IN PORTIONS OF THE SITE WHERE CONSTRUCTION ACTIVITIES HAVE BEEN TEMPORARILY OR PERMANENTLY CEASED. STABILIZATION BMPS MAY INCLUDE TEMPORARY SEEDING, PERMANENT SEEDING, MULCHING, GEOTEXTILES, SOD STABILIZATION, SWALE SODDING, VEGETATIVE BUFFER STRIPS, PROTECTION OF TREES, PRESERVATION OF MATURE VEGETATION, AND OTHER APPROPRIATE MEASURES.
  6. CONTRACTOR SHALL USE OTHER STRUCTURAL BMPS, AS NECESSARY, TO DIVERT RUNOFF FROM EXPOSED SOILS, STORE RUNOFF AND/OR SEDIMENT ON-SITE, OR OTHERWISE LIMIT RUNOFF AND THE DISCHARGE OF POLLUTANTS FROM EXPOSED AREAS OF THE SITE.
  7. CONTRACTOR SHALL INSPECT AND MAINTAIN ALL SEDIMENT AND EROSION CONTROL BMPS TO ASSURE PROPER OPERATION. INSPECTIONS SHALL OCCUR AT A MINIMUM INTERVAL OF ONCE EVERY 7 CALENDAR DAYS AND WITHIN 24 HOURS OF THE END OF A STORM THAT IS 1/4-INCH OR GREATER.
  8. ANY MAINTENANCE OPERATIONS NEEDED TO ASSURE PROPER OPERATION OF ALL CONTROLS, SHALL BE DONE IN A TIMELY MANNER, BUT IN NO CASE LATER THAN 7 CALENDAR DAYS FOLLOWING THE INSPECTION IN WHICH THE NEED IS IDENTIFIED.
  9. ONCE CONSTRUCTION IS COMPLETED AND FINISHED GRADING AND FINAL STABILIZATION HAS BEEN ACHIEVED, SILT BARRIERS SHALL BE COMPLETELY REMOVED TO THE SATISFACTION OF THE ENGINEER AND PRIOR TO FINAL ACCEPTANCE.

<b>BIDDING NOTES:</b>

  1. ALL PROPOSED CONSTRUCTION WITHIN LIMITS OF WORK AREAS ARE PART OF PIPE, INLET AND / OR MANHOLE CONSTRUCTION.
  2. PRICE FOR ALL REMOVAL, AS SHOWN ON THE PLANS OUTSIDE OF CONSTRUCTION EXCAVATION AREA, SHALL BE INCLUDED IN THE VARIOUS ITEMS OF THE STORMWATER UNIT PRICES.
  3. CONTRACTOR SHALL BE RESPONSIBLE FOR PULLING RIGHT-OF-WAY USE PERMITS FOR CITY OF TAMPA.
  4. CONTRACTOR SHALL BE RESPONSIBLE FOR PULLING RIGHT-OF-WAY USE PERMIT FOR HILLSBOROUGH COUNTY IF DETERMINED ONE IS NEEDED.
  5. CONTRACTOR RESPONSIBLE FOR OBTAINING TREE REMOVAL PERMITS AND GRAND TREE REMOVAL NOTICING. CONTRACTOR RESPONSIBLE FOR ANY PERMITTING NECESSARY FOR TREE TRIMMING AND ROOT PRUNING FOR BOTH GRAND AND NON-GRAND TREES.
  6. CONTRACTOR RESPONSIBLE FOR SUPPLYING ALL MOT PLANS.
  7. PRIOR TO CONSTRUCTION CONTRACTOR TO RECORD LIMITS OF CONSTRUCTION AREA AND DOCUMENT ALL UNIQUE AND SPECIAL FEATURES OF RESIDENTIAL YARD AREAS WITHIN ROW LIMITS. CONTRACTOR SHALL AT BEST EFFORT PRESERVE ALL SPECIAL AND UNIQUE FEATURES INCLUDING BUT NOT LIMITED TO BRICK PAVERS FOR DRIVEWAYS AND WALKWAYS, MAILBOXES, LANDSCAPE PLANTERS AND OTHER FEATURES, TREES, ETC. CONTRACTOR SHALL PERFORM RESTORATION OF ANY FEATURES REMOVED.
  8. ALL BOX CULVERTS AND STORM PIPE SHALL BE WATER TIGHT. BOX CULVERT AND STORM PIPE TRENCH BACKFILLING SHALL CONFORM TO FDOT STANDARD SPECIFICATIONS 125. BOX CULVERT BACKFILLING WILL BE UNDER WET CONDITIONS AND SHALL CONFORM SPECIFICALLY TO FDOT STANDARD SPECIFICATION 125.8.3.4 WITH COARSE AGGREGATE PIPE BEDDING WRAPPED IN FILTER FABRIC.
  9. LIMITS OF DISTURBED OPEN CUT AREAS MAY VARY DEPENDENT UPON CONTRACTOR MEANS AND METHODS. CONSTRUCTION OPTIONS INCLUDE BUT NOT LIMITED TO INCLUDE SHEET PILING, SLOPED OPEN CUT, AND TRENCH BOX. CONSTRUCTION PLANS AND SPECS ASSUME A SLOPED OPEN CUT TRENCH.

<b>WOODMERE & LOIS AVENUE DRAINAGE IMPROVEMENTS NOTES SHEET</b>

No.DATEREVISIONSNo.DATEREVISIONSDES: SEB
36DRN: BB
25CKD: JDM
14DATE: 05/21/25
CITY of TAMPA
Mobility Department
Stormwater Engineering Division
WOODMERE & LOIS AVENUE
DRAINAGE IMPROVEMENTS
NOTES SHEET
SHEET
3
OF 9

Every printed table on this sheet, recovered as rows and cells.

Revision block

3 | | 6 | | | DR
2 | | 5 | | | CK
Sheet
4 of 9 civil
Text lines
1,122 each located on the sheet
Symbols
44 11 classes
Viewports
3 titled drawings found

WOODMERE & LOIS AVENUE DRAINAGE IMPROVEMENTS - PLAN AND PROFILE

This plan-and-profile sheet directs the construction of proposed stormwater drainage along South Lois Avenue / W. Dale Avenue (Woodmere & Lois Avenue), consisting of segments of 12"x18" ERCP and 18" RCP tied together by seven drainage structures (Type II inlets, Type BR-1 inlets, and Type "J" stormwater manholes). It also calls for F.D.O.T. Type "F" curb & gutter and profile milling beginning at STA. 21+82, EL = 1.67'. Existing utilities, water mains, and gas lines are shown for avoidance, with several callouts noting offsets to be done by others.

Viewports

TitleKindScaleContents
PLAN VIEWplan view1" = 20'Plan of the South Lois Ave. / W. Dale Ave. area showing proposed 12"x18" ERCP and 18" RCP alignments, drainage structures ST-1 through ST-7, F.D.O.T. Type "F" curb & gutter, existing/existing utilities (water, gas, telecom, reclaimed water), right-of-way, concrete sidewalk/curb, trees, and a MATCH LINE at STA. 24+00. Includes linear pipe callouts such as PROP. 28 LF OF 12"x 18" RCP, PROP. 87 LF OF 12"x18" ERCP, PROP. 54 LF OF 18" RCP, PROP. 31 LF OF 12"x 18" RCP, PROP. 36 LF OF 12"x 18" ERCP, PROP. 4 LF OF 15" RCP, and PROP. 140 LF OF 18" RCP.
PROFILEprofile view1" = 2' VERT., 1" = 20' HORIZ.Longitudinal profile of the proposed line from STA. 20+50 to 24+00 showing C/L Existing Grade and C/L PROPOSED Grade, proposed 12"x18" ERCP at 0.2%, 0.14% and 0.64% and 18" RCP at 0.42% and 0.34%, invert elevations at each structure, and existing utilities (water mains, gas, telecom, reclaimed water, BFOOT) with CAUTION callouts.
S.U.E. (SUBSURFACE UTILITY ENGINEERING) TEST HOLE FIELD DATAtablenoneTest-hole field data table listing Test Hole Number (VWH101–VWH117), Utility Size/Material & Type, Northing, Easting, Ground Elevation, Depth (Top), Elevation (Top), Utility Owner, Utility Direction, and Surface Type.

Quantities this sheet can support

linear feet of 12"x18" ERCP (multiple proposed segments)linear feet of 18" RCP (multiple proposed segments)linear feet of 15" RCPcount and type of drainage structures (Type II inlet, Type BR-1 inlet, Type "J" stormwater manhole) with rim/throat/invert elevationslinear feet of F.D.O.T. Type "F" curb & guttertest-hole field data entries (VWH101–VWH117)profile milling location/quantity (STA. 21+82, EL = 1.67')

Key notes read from the sheet

  • BEGIN PROFILE MILLING STA. 21+82, EL= 1.67'
  • OFFSET 6" WATER (BY OTHERS)
  • OFFSET UTILITY (BY OTHERS)
  • END PROP. F.D.O.T. TYPE "F" CURB & GUTTER
  • BEGIN PROP. F.D.O.T. TYPE "F" CURB & GUTTER
  • MATCH LINE STA. 24+00
  • CAUTION (multiple callouts near existing water/gas/telecom utilities)
  • PROP. 87 LF OF 12"x18" ERCP OFFSET 6" WATER (BY OTHERS)
  • Structure data e.g. ST-1 PROP. TYPE II INLET STA. 21+19, 6.5' RT. RIM ELEV. 13.95 THROAT ELEV. 13.51 12"x18" ERCP INV. ELEV.10.30(NE); ST-7 PROP. STORMWATER MANHOLE (TYPE "J") STA. 23+46, 27' RT. RIM ELEV. 13.30 INV. 18" RCP. ELEV. 7.12(S) INV. 15" RCP. ELEV. 9.25(E) INV. 12"x18" ERCP ELEV. 10.85(W)

Every line on the sheet is typed by what it is: a structure callout, a station, an invert value, a utility witness tag, a proposed or existing note. That is what makes an annotation addressable rather than merely readable. Hover a row to light every instance of that type on the sheet.

Annotation typeCountExample
Structure callout25ST-1
Station1018+00
Proposed work callout21PROP. STORMWATER MANHOLE (TYPE "J")
Existing condition callout43Ex. 8" Reclaimed| Water
Invert or rim value38BEGIN PROP. F.D.O.T. TYPE "F" CURB & GUTTER
Pipe or utility spec23Not Field Verified Size Wrapped DIP WM
Utility witness tag161VVH #111
Spot elevation62-14.41
Note or long string23Not Field Verified Size Clay Sanitary Sewer
Other lettering716VATER MANHOLE (TYPE "J")

Surveyed symbols found on this sheet, named by the set's own legend. Hover a class to light every instance at once. Counts are reported as found, never adjusted to match an expectation.

Legend classCount
water valve cover9
shared utility pole6
telephone pedestal6
reclaimed water valve cover5
water meter4
iron pipe4
sanitary manhole3
drainage manhole2
single support sign2
post2
light pole1

Every instance, with the callouts printed beside it

Each located symbol, and the text on the sheet within reach of it, nearest first. Distances are real feet at the sheet scale, not pixels. Where a callout carries an identifier that names this kind of feature, it is promoted to ID; proximity alone does not establish labelling, agreement does. Hover a row to zoom to that symbol.

SymbolStationIDCallouts within reach
reclaimed water valve cover23+77.97·OHL  14.65  CURB & GUTTER
shared utility pole24+08.53·RCW  OHL  CURB & GUTTER
telephone pedestal24+09.63·13.99  Ex. 6"WM  CURB & GUTTER
water meter24+23.67·Ex. 6"WM  G
iron pipe24+26.27·Ex. 1-4  Ex. Gas
post24+44.73·4.1  -14.41  +14.4
iron pipe24+50.87·Ex. 1-4
sanitary manhole24+52.13·21+00  ST-1  Ex. 6"WM
light pole24+64.00·+13.8  SL-1  21+00
telephone pedestal24+70.64·ST-1  Ex. 8" DIP WM
reclaimed water valve cover24+75.17·16.4  Ex. 96 BFOT/FTR  PROP. 36 LF OF 12"x|18" ERCP
iron pipe24+75.12·BFOT(B)  Ex.x,8" VCP.
shared utility pole24+78.24·+13.8  RCW  Ex. 8" DIP WM
water valve cover24+81.71·Ex. 8" DIP WM
water valve cover25+03.74VVH#107VVH#107  VVH#106  VVH|#106
water valve cover25+03.74VVH#106VVH#106  VVH#107  VVH|#106
water valve cover25+04.04VVH#104VVH#104  VVH#106  VVH|#106
water valve cover25+07.01VVH#107VVH#107  VVH#106  VVH|#106
water valve cover25+07.41VVH #10314.48  VVH #103  VVH #102
water valve cover25+08.17VVH #111S  VVH #111  12.00
sanitary manhole25+10.23·S  VVH#107  VVH#106
reclaimed water valve cover25+16.76V-7RCW  V-7  V-8
reclaimed water valve cover25+16.17V-8V-8  RCW  V-7
reclaimed water valve cover25+21.28V-7RCW  V-7  V-8
shared utility pole25+24.96·W  BT(B)  12.00
shared utility pole25+27.52·BT(B)  S  W
water meter25+30.04·W  75.75  15.75
single support sign25+31.70·G  ST-3  VVH#101
telephone pedestal25+38.74·Ex. 2" Water  Ex. 30  Ex. 4" Conc. Curb
water meter25+39.90·G  ST-3
drainage manhole25+56.70·ST-4
iron pipe25+59.97·22+00
water valve cover26+00.30·G  Ex. Gas|  Ex. 8" Reclaimed| Water
water meter26+17.55·BT(P)  BT(D)  Ex. 4" Gas
telephone pedestal26+47.89·BT(B)  CAS(B)  CAS(D)
sanitary manhole26+70.37S-5S-5  S  ST-5
post26+72.13·SL-2  BT(D)
single support sign26+75.61·SL-2  BT(D)
telephone pedestal26+92.76·ST-6  CAS(B)  ST-7
telephone pedestal26+92.96·BT(D)  ST-5  8" VCP
drainage manhole26+95.96·S  ST-7  8" VCP
water valve cover27+00.84VVH #109W  VVH #109  8" VCP
shared utility pole27+09.90·OHL  BT(B)  Ex. 8'
shared utility pole27+15.99·OHL  Ex. 8'  Ex. 2"

1,122 lines read from this sheet, including rotated title block lettering. The 400 longest are listed here. Hover a row to zoom to it on the sheet.

TextConfidenceType
BEGIN PROP. F.D.O.T. TYPE "F" CURB & GUTTER0.996Invert or rim value
Not Field Verified Size Clay Sanitary Sewer1.0Note or long string
Electronic Depth Only - Fiber Optic Cable0.997Note or long string
Electronic Depth Only - Fiber Optic Cable0.997Note or long string
Electronic Depth Only - Fiber Optic Cal1.0Note or long string
Electronic Depth Only - Fiber Optic Cal1.0Note or long string
30" Not Field Verified Reclaimed Water0.986Note or long string
30" Not Field Verified Reclaimed Water1.0Note or long string
Not Field Verified Size Wrapped DIP WM1.0Pipe or utility spec
(Size measured in inches and is O.D.)1.0Note or long string
4" Polyethylene Buried Telephone x 20.999Note or long string
PROP. STORMWATER MANHOLE (TYPE "J")0.992Proposed work callout
PROP. STORMWATER MANHOLE (TYPE "J")0.988Proposed work callout
12" Cast Iron Pipe Reclaimed Water0.996Note or long string
8" Cast Iron Pipe Reclaimed Water0.995Note or long string
8" Cast Iron Pipe Reclaimed Water1.0Note or long string
INV. 12"×18" ERCP ELEV. 11.10(W)0.977Invert or rim value
INW. 12"x18" ERCP ELEV. 11.20(S)0.972Pipe or utility spec
INW. 12"x18" ERCP ELEV. 7.90(NW)0.973Pipe or utility spec
INV. 12"×18" ERCP ELEV. 10.85(W)0.98Invert or rim value
INV. 12"×18" ERCP ELEV. 7.70(SE)0.976Invert or rim value
INV. 12"×18" RCP ELEV. 10.13(SW)0.97Invert or rim value
(SUBSURFACE UTILITY ENGINEERING)1.0Note or long string
6" Not Field Verified Water Main1.0Note or long string
Stormwater Engineering Division1.0Note or long string
Utility Size, Material & Type1.0Note or long string
PROP. 28 LF OF 12"x 18" ERCP0.993Proposed work callout
PROP. 31 LF OF 12"x 18" ERCP0.971Proposed work callout
PROP. 36 LF OF 12"x|18" ERCP0.97Proposed work callout
6" Cast Iron Pipe Water Main0.989Note or long string
6" Cast Iron Pipe Water Main0.989Note or long string
6" Cast Iron Pipe Water Main0.989Note or long string
PROP. 87 LF OF 12"x18" ERCP0.987Proposed work callout
OFFSET 6" WATER (BY OTHERS)0.998Note or long string
END PROP. F.D.O.T. TYPE "F"0.982Note or long string
INV. 18" RCP. ELEV. 7.12(N)0.961Invert or rim value
INV. 18" RCP. ELEV. 7.12(S)0.987Invert or rim value
INV. 15" RCP. ELEV. 9.25(E)0.994Invert or rim value
END PROP. F.D.O.T. TYPE "I0.968Note or long string
OFFSET UTILITY (BY OTHERS)0.984Note or long string
INV. 18" RCP ELEV. 7.70(N)0.99Invert or rim value
PROP. 12" x 18" ERCP @ .2%0.973Proposed work callout
VATER MANHOLE (TYPE "J")0.987Other lettering
2" Polyethylene Gas Main0.995Other lettering
2" Polyethylene Gas Main0.998Other lettering
Buried Frontier(x2)(AL)0.999Other lettering
Ex. 8" Reclaimed| Water0.94Existing condition callout
PROP. 140 LF OF 18" RCP0.972Proposed work callout
PROP. 54 LF OF 18" RCP0.991Proposed work callout
- BT(D) -N00°48(1)2"E0.845Other lettering
Ex. 8" Reclaimed Water0.954Existing condition callout
Ex. 4" Telephone Cable0.985Existing condition callout
WOODMERE & LOIS AVENUE0.991Other lettering
BEGIN PROFILE MILLING1.0Other lettering
- BT(D)-N00°48(1)2"E0.841Other lettering
PROP. TYPE BR-1 INLET0.999Proposed work callout
PROP. TYPE BR-1 INLET0.999Proposed work callout
STA. 22+06, 22.5' RT.0.975Other lettering
OFFSET UTILITY (BY O)0.981Other lettering
PROP. 4 LF OF 15" RCP0.95Proposed work callout
PROP. 18" RCP @ 0.42%0.98Proposed work callout
PROP. 18" RCP @ 0.34%0.977Proposed work callout
DRAINAGE IMPROVEMENTS1.0Other lettering
STA. 21+19, 6.5' RT.0.961Other lettering
”RCP ELEV. 10.13(SW)0.972Pipe or utility spec
PROP. 12" x 18" ERCP0.964Proposed work callout
TEST HOLE FIELD DATA1.0Other lettering
Ex. 8" RCW/16" Steel0.976Existing condition callout
Ex. 4" COND W/2 BFOT0.993Existing condition callout
PROP. 12" x 18" ERCP0.982Proposed work callout
Ex. FiberOptic Cable0.999Existing condition callout
Buried Frontier(AL)0.998Other lettering
Buried Frontier(AL)0.987Other lettering
PROP. TYPE II INLET0.976Proposed work callout
PROP. TYPE II INLET0.979Proposed work callout
INV. 12"x18" ERCP E0.97Invert or rim value
INV. ELEV.10.30(NE)0.996Invert or rim value
PROP. TYPE II INLET0.963Proposed work callout
STA. 23+42, 34' RT.0.974Other lettering
STA. 21+47, 43' RT.0.982Other lettering
INV. ELEV. 11.25(N)0.986Invert or rim value
STA. 23+46, 27' RT.0.979Other lettering
STA. 23+46, 27’ RT.0.948Other lettering
STA. 21+83, 43' RT.0.972Other lettering
INV. 12"x18" ERCP E0.948Invert or rim value
Buried Frontier(AL)1.0Other lettering
PROP. 12"x 18" ERCP0.981Proposed work callout
Mobility Department0.998Other lettering
Buried 200 & 400BT0.989Other lettering
STA. 23+42, 7' RT.0.948Other lettering
STA. 23+42, 7’ RT.0.936Other lettering
THROAT ELEV. 13.510.996Invert or rim value
THROAT ELEV. 13.030.998Invert or rim value
STA. 23+42, 34’RT.0.972Other lettering
THROAT ELEV. 13.030.997Invert or rim value
THROAT ELEV. 13.200.994Invert or rim value
INV. ELEV. 9.50(E)0.972Invert or rim value
PROP. STORMWATER N0.974Proposed work callout
THROAT ELEV. 13.200.996Invert or rim value
C/L PROPOSED GRADE0.974Other lettering
C/L Existing Grade1.0Other lettering
Ex. 4" Conc. Curb0.973Existing condition callout
- BT(D)-N00°4842E0.816Other lettering
QOBT(B) = = - - -0.837Other lettering
Ex. 8' Conc. Wall0.977Existing condition callout
Ex. 8’ Conc. Wall0.967Existing condition callout
Ex. 8' Conc. Wall0.974Existing condition callout
Ex. 8’ Conc. Wall0.975Existing condition callout
INV. 12"x18" ERCP0.965Invert or rim value
INV. 12"x18" RCP 0.91Invert or rim value
8" DIP Water Main0.996Other lettering
STA. 21+19, 6.5’0.947Other lettering
STA. 21+47, 43’R0.947Other lettering
STA. 21+83, 43’R0.939Other lettering
Reclainted Water0.983Other lettering
INV. 12"x18” RCP0.919Invert or rim value
E/Side Lois Ave.1.0Other lettering
E/Side Lois Ave.0.986Other lettering
Inv. El. 6.49(E)0.98Invert or rim value
PLAN AND PROFILE1.0Other lettering
Reclaimed Water1.0Other lettering
SCALE: 1" = 20'0.945Other lettering
SCALE: 1” = 20'0.963Other lettering
Reclaimed Water0.999Other lettering
OFFSET 6" WATER0.966Other lettering
Buried Frontier0.998Other lettering
RIM ELEV. 13.950.97Invert or rim value
RIM ELEV. 13.470.995Invert or rim value
GOBT(B) = = - -0.834Other lettering
RIM ELEV. 13.470.995Invert or rim value
RIM ELEV. 13.590.997Invert or rim value
RIM ELEV. 13.300.997Invert or rim value
RIM ELEV. 13.970.984Invert or rim value
RIM ELEV. 13.610.989Invert or rim value
Ex. 96 BFOT/FTR0.998Existing condition callout
1” = 20' HORIZ.0.901Other lettering
Conc. Sidewalk0.999Other lettering
Conc. Sidewalk0.995Other lettering
Ex. 8” RCW/16"0.963Existing condition callout
NV. L. 7.7 (N)0.775Other lettering
DATE: 05/21/250.968Other lettering
4" Conc. Curb0.976Other lettering
4" Conc. Curb0.965Other lettering
Ex. 8" DIP WM0.987Existing condition callout
CURB & GUTTER0.982Invert or rim value
4" Conc. Curb0.99Other lettering
3° Deflection0.962Other lettering
4" Conc. Curb0.969Other lettering
RCW CASG45(0)0.778Other lettering
x. 1-4” COND.0.913Other lettering
NN. 0. .85 W)0.714Other lettering
CITY of TAMPA0.985Other lettering
Ex. 2" Water0.979Existing condition callout
Ex.x,8" VCP.0.882Existing condition callout
4' PVC Fence0.971Pipe or utility spec
Frontier(AL)1.0Other lettering
12"x18" ERCP0.932Pipe or utility spec
- - -- BT(D)0.766Other lettering
12"x18" ERCP0.938Pipe or utility spec
CAS(B) CAS(D0.949Other lettering
6' PVC Fence0.925Pipe or utility spec
Inv. 9.45(E)0.997Invert or rim value
Steel Casing0.998Other lettering
V. E 770 (N)0.582Other lettering
NV. E 72 (S)0.728Other lettering
N. .E .O (E)0.658Other lettering
(v. 9.45(N)0.808Other lettering
= 20’ HORIZ.0.901Other lettering
ATLAS 1 - 90.893Other lettering
STA. 21+82,0.982Other lettering
4’PVC Fence0.971Pipe or utility spec
(BY OTHERS)0.992Other lettering
H - - BT(D)0.771Other lettering
Conc_,} D/W0.834Other lettering
RESIDENTIAL1.0Other lettering
16.16+16.200.959Other lettering
-Ex. 2” Gās0.848Other lettering
'x|18" ERCP0.933Pipe or utility spec
Ex o o ole0.721Existing condition callout
-Ex. 8" RCW0.964Other lettering
Water w/ 420.981Other lettering
LE. 25 (E)0.65Other lettering
1 = 2 VERT.0.933Other lettering
SW 2023-140.981Other lettering
Ex. 4" Gas0.918Existing condition callout
BRICK WAUK0.942Other lettering
- − BT(D)0.811Other lettering
Conc. Curb0.994Other lettering
CAS(B) RCW0.954Other lettering
CAS(D) — -0.879Other lettering
'x|18"ERCP0.923Pipe or utility spec
Ex. 6" WM.0.935Existing condition callout
1311046.231.0Other lettering
1311041.131.0Other lettering
1311030.341.0Other lettering
Ex. 2" Gas0.96Existing condition callout
1311027.631.0Other lettering
Wastewater1.0Other lettering
1311027.081.0Other lettering
1311029.961.0Other lettering
Ex. 2" Gas0.978Existing condition callout
1311026.321.0Other lettering
1311587.871.0Other lettering
Ex. 600 BT0.976Existing condition callout
Ex. 8" RCW0.967Existing condition callout
1311224.791.0Other lettering
1310985.231.0Other lettering
1311031.381.0Other lettering
1311376.661.0Other lettering
Ex. 600 BT0.996Existing condition callout
1311370.201.0Other lettering
Ex. 600 BT0.989Existing condition callout
1311371.671.0Other lettering
1311367.871.0Other lettering
Ex. 600 BT0.958Existing condition callout
Ex. 8" VCP0.957Existing condition callout
1311369.461.0Other lettering
30 Reclair0.957Other lettering
1311375.551.0Other lettering
V.EL 7 (S)0.637Other lettering
LEV712 (N)0.846Other lettering
V.. L..9(W0.57Other lettering
V. E. 9(NW0.571Other lettering
ott 0250.718Other lettering
= 2' VERT.0.949Other lettering
ATLAS 1-90.984Other lettering
EL= 1.67'0.963Other lettering
BRICK WAK0.998Other lettering
(Retired)1.0Other lettering
Conc. D/W0.986Other lettering
Conc. S/W0.998Other lettering
CQnc_ D/W0.865Other lettering
Conc. D/W0.958Other lettering
- - BT(B)0.809Other lettering
ONE STORY1.0Other lettering
Conc. D/W0.979Other lettering
- - BT(B)0.806Other lettering
PLAN VIEW0.989Other lettering
Test Hole1.0Other lettering
Elevation1.0Other lettering
Direction1.0Other lettering
Elevation1.0Other lettering
490209.751.0Other lettering
Ex. 6" WM0.949Existing condition callout
490211.321.0Other lettering
ned Water1.0Other lettering
Ex. 6” WM0.878Existing condition callout
490219.271.0Other lettering
TOP 11.241.0Other lettering
490208.071.0Other lettering
TOP 11.130.999Other lettering
490204.401.0Other lettering
490203.111.0Other lettering
TOP 10.420.977Other lettering
490202.131.0Other lettering
490184.211.0Other lettering
TOP 10.630.999Other lettering
TOP 10.311.0Other lettering
490179.761.0Other lettering
490172.691.0Other lettering
490144.961.0Other lettering
ned Water1.0Other lettering
490209.491.0Other lettering
490210.891.0Other lettering
8" VCP WW0.903Pipe or utility spec
490212.721.0Other lettering
490224.811.0Other lettering
490232.611.0Other lettering
Reclaimed1.0Other lettering
490238.321.0Other lettering
V 7 0 S)0.636Other lettering
V.. 79GW)0.538Other lettering
V. E 5 E)0.604Other lettering
WNV. 120.678Other lettering
REVISIONS1.0Other lettering
REVISIONS1.0Other lettering
BOT(B) -0.84Other lettering
// INLET0.953Other lettering
Ex. Gas-0.981Existing condition callout
6.5’ RT.0.89Other lettering
VVH #1110.988Utility witness tag
STA 24000.751Other lettering
(x2)(AL)0.954Other lettering
(×2)(AL)0.945Other lettering
1. 13.510.909Other lettering
Siaewark0.704Other lettering
BFOTROTW0.613Other lettering
6" Water0.935Other lettering
Ex. 6"WM0.963Existing condition callout
/. 13.200.846Other lettering
VVH #1090.993Utility witness tag
VVH|#1060.958Utility witness tag
AVH #1050.912Other lettering
− CAS( )0.739Other lettering
− CAS( )0.704Other lettering
CAS(D) —0.937Other lettering
VVH #1020.991Utility witness tag
VVH #1030.963Utility witness tag
3.0' Dpl0.92Other lettering
24.445.80.999Other lettering
3/4" Gas0.932Other lettering
Ex. Gas|0.889Existing condition callout
16.206.00.991Other lettering
22.5’RT.0.955Other lettering
Northing1.0Other lettering
TOP12.741.0Other lettering
Frontier1.0Other lettering
TOP 9.630.999Other lettering
TOP 6.951.0Other lettering
TOP 8.101.0Other lettering
V. .NE)0.776Other lettering
V. (S)0.59Other lettering
v.9.5(N)0.829Other lettering
PLAN ANI0.967Other lettering
3.0' Dp0.849Other lettering
11119260.865Other lettering
BFOT(B)0.975Pipe or utility spec
Ex. 30"0.956Existing condition callout
BT(B) -0.86Other lettering
BFOT(B)1.0Pipe or utility spec
Sidewak0.936Other lettering
8" Wall0.908Other lettering
BFOT(B)1.0Pipe or utility spec
Retired1.0Other lettering
BTBT(B)0.753Other lettering
- BT( )0.757Other lettering
BT(B) -0.878Other lettering
BT(B) =0.95Other lettering
- BT(D)0.921Other lettering
CQncD/W0.909Other lettering
15" RCP0.874Pipe or utility spec
VVH#1070.941Utility witness tag
VVH#1060.98Utility witness tag
NVH#1050.929Other lettering
VVH#1010.988Utility witness tag
(8)18 -0.769Other lettering
(8)T) -0.561Other lettering
BT)(18)0.639Other lettering
VVH#1040.958Utility witness tag
Ex. 1-40.936Existing condition callout
CAS(B)0.827Utility witness tag
CAS(D)—0.929Other lettering
CAS(D)-0.948Other lettering
CAS(D)—0.936Other lettering
CASRPCW0.807Other lettering
CAS(B(G0.798Other lettering
CAUTION1.0Other lettering
-Ex. 8"0.918Other lettering
3.0' Dp0.974Other lettering
CAUTION1.0Other lettering
Ex. Gas1.0Existing condition callout
23" DOC0.928Other lettering
3.0' Dp0.985Other lettering
NE STRY0.747Other lettering
RPENEET0.764Other lettering
atdrole0.725Other lettering
@ 0.14%0.99Other lettering
Utility1.0Other lettering
Utility1.0Other lettering
Surface1.0Other lettering
96 BFOT0.999Pipe or utility spec
Easting1.0Other lettering
VVH-1100.997Utility witness tag
Asphalt1.0Other lettering
Asphalt0.981Other lettering
VVH-1090.995Utility witness tag
Asphalt1.0Other lettering
CAUTION1.0Other lettering
Retired1.0Other lettering
Asphalt1.0Other lettering
VVH-1030.984Utility witness tag
CAUTION1.0Other lettering
Asphalt1.0Other lettering
VWH-1040.934Other lettering
VVH-1040.997Utility witness tag
Asphalt1.0Other lettering
CAUTION1.0Other lettering
Asphalt1.0Other lettering
VVH-1010.997Utility witness tag
VVH-1050.992Utility witness tag
VVH-1060.997Utility witness tag
Asphalt1.0Other lettering
Asphalt1.0Other lettering
VVH-1020.996Utility witness tag
Asphalt1.0Other lettering
VWH-1070.923Other lettering
VVH-1070.997Utility witness tag
Asphalt1.0Other lettering
Asphalt1.0Other lettering
Asphalt1.0Other lettering
@ 0.64%0.994Other lettering
Asphalt1.0Other lettering
.. 125(0.614Other lettering
V. 20)0.571Other lettering
ot D1250.707Other lettering
VE (E)0.711Other lettering
2'VERT.0.954Other lettering
Inv. 9.0.99Invert or rim value
PROFILE1.0Other lettering
- RCW-0.979Other lettering

The sheet as continuous text, in the order a person would read it. Note columns become prose, printed tables stay tables.

SW 2023-14

Test Hole NumberUtility Size, Material & Type (Size measured in inches and is O.D.)NorthingEastingGround ElevationDepth (Top)Elevation (Top)Utility OwnerUtility DirectionSurface Type
VVH1018" Cast Iron Pipe Reclaimed Water1311046.23490209.7513.96'3.33'10.63'COTE-WAsphalt
VVH10230" Not Field Verified Reclaimed Water1311041.13490211.3213.84'6.89'6.95'COTN-SAsphalt
VVH1032" Polyethylene Gas Main1311030.34490219.2714.03'2.90'11.13'TECOE-WAsphalt
VVH1048" Cast Iron Pipe Reclaimed Water1311027.63490208.0713.78'3.36'10.42'COTE-WAsphalt
VVH1054" Polyethylene Buried Telephone x 21311027.08490204.4013.69'3.38'10.31'FrontierE-WAsphalt
VVH1068" DIP Water Main1311029.96490203.1113.63'4.00'9.63'COTNE-SWAsphalt
EDO107Electronic Depth Only - Fiber Optic Cable1311026.32490202.1313.67'5.6'8.1'FDOTE-WAsphalt
VVH1086" Cast Iron Pipe Water Main1311587.87490184.2112.40'1.20'11.20'COTE-WSoil
VVH1096" Cast Iron Pipe Water Main1311224.79490179.7613.68'2.44'11.24'COTE-WSoil
VVH1106" Cast Iron Pipe Water Main1310985.23490172.6914.65'1.91'12.74'COTE-WSoil
VVH11130" Not Field Verified Reclaimed Water1311031.38490144.9612.24'8.06'4.18'COTN-SAsphalt
VVH1126" Not Field Verified Water Main1311376.66490209.4913.17'2.8'10.4'COTNE-SWAsphalt
EDO113Electronic Depth Only - Fiber Optic Cable1311370.20490210.8913.14'7.50'5.64'FDOTE-WAsphalt
VVH11412" Cast Iron Pipe Reclaimed Water1311371.67490212.7213.06'2.26'10.80'COTE-WAsphalt
VVH1152" Polyethylene Gas Main1311367.87490224.8113.22'3.03'10.19'TECOE-WAsphalt
VVH116Not Field Verified Size Clay Sanitary Sewer1311369.46490232.6113.44'3.68'9.76'COTN-SAsphalt
VVH117Not Field Verified Size Wrapped DIP WM1311375.55490238.3213.53'2.68'10.85'COTN-SAsphalt

DES: SEB DRN: BB CKD: JDM DATE: 05/21/25

CITY of TAMPA Mobility Department Stormwater Engineering Division

WOODMERE & LOIS AVENUE DRAINAGE IMPROVEMENTS PLAN AND PROFILE

SHEET 4 OF 9

Every printed table on this sheet, recovered as rows and cells.

Revision block

23+00 24+00 No. | DATE | REVISIONS | No. | DATE | REVISIONS | DE | DR | CK

Sheet
5 of 9 civil
Text lines
1,205 each located on the sheet
Symbols
87 13 classes
Viewports
3 titled drawings found

WOODMERE & LOIS AVENUE DRAINAGE IMPROVEMENTS — PLAN AND PROFILE

This sheet lays out the proposed stormwater drainage improvements for the Woodmere & Lois Avenue project, showing a plan view of the proposed pipe runs and drainage structures (ST‑8 through ST‑15) through the South Lois Ave / West Azeele St / Horatio St area, and a longitudinal profile giving pipe invert elevations and slopes. It directs the contractor to install proposed reinforced concrete pipe (RCP) in 18 in, 15 in and 12 in × 18 in ERCP, with associated Type I and Type II inlets and stormwater manholes, terminating/tying into existing stormwater manhole D‑18. The profile also requires offsetting existing 6 in water lines and constructing new ramps per FDOT Index 522‑002, and removing/replacing an existing concrete sidewalk in a hatched area.

Viewports

TitleKindScaleContents
PLAN VIEWplan viewnone printed (graphical scale bar at upper right reads SCALE: 1" = 20")Street grid (SOUTH LOIS AVE., WEST AZEELE ST., HORATIO ST., WOODMERE AVE.) with proposed and existing storm lines, proposed RCP/ERCP run lengths called out, structure bubbles ST‑8 to ST‑15, existing utilities (water, gas, VCP wastewater, fiber‑optic/telephone cable, reclaimed water), concrete curbs/sidewalks, a hatched area of existing concrete sidewalk to be removed and replaced, and a 'CONSTRUCT NEW RAMPS PER FDOT INDEX 522‑002' note. North/scale graphic at upper right.
PROFILE VIEWprofile viewSCALE: 1" = 2' VERT. / 1" = 20' HORIZ.Longitudinal profile from station 24+00 to 28+50 with C/L Proposed Grade and C/L Existing Grade curves, proposed 18 in and 15 in RCP and 12 in × 18 in ERCP invert elevations with segment slopes (e.g. 0.34%, 0.35%, 0.52%, 0.21%, 0.32%, 0.93%, 0.25%, 0.30%), structure locations, existing utility crossings, a 'CAUTION' callout, and 'CONNECT TO EX. STORMWATER MANHOLE D‑18'.
Structure schedule (ST‑8 … ST‑15, D‑18)table / schedule blocknoneRight‑hand schedule listing each structure with station, type (Type I inlet, Type II inlet, stormwater manhole Type 'J'/'J1'), rim elevation, top/throat elevation, and invert elevations for the 18 in / 15 in / 12 in×18 in RCP connections (N/S/E/W); final line D‑18 gives the connection to existing stormwater manhole D‑18 at Sta 27+39, 26' RT, rim 12.10, 18 in RCP inv 5.88(S), 15 in RCP inv 7.75(E).

Quantities this sheet can support

linear feet of proposed 18" RCP (e.g. 54 LF, 77 LF, 182 LF, plus profile segments)linear feet of proposed 15" RCP (e.g. 20 LF, 18 LF, 41 LF, 10 LF)linear feet of proposed 12" x 18" ERCP (23 LF)linear feet of 18" RCP to connect to ex. manhole D‑18 (23 LF)count of proposed drainage structures (inlets and stormwater manholes, ST‑8 through ST‑15)structure rim/throat/invert elevations and pipe slopes for each reachlinear feet of existing concrete sidewalk to be removed and replaced (hatched area)

Key notes read from the sheet

  • PROP. 54 LF OF 18" RCP / PROP. 20 LF OF 15" RCP / PROP. 77 LF OF 18" RCP / PROP. 18 LF OF 15" RCP / PROP. 41 LF OF 15" RCP / PROP. 23 LF OF 12" X 18" ERCR / PROP. 10 LF OF 15" RCP / PROP. 182 LF OF 18" RCP / PROP. 23 LF OF 18" RCP CONNECT TO EX. MANHOLE D‑18
  • OFFSET 6" WATER (BY OTHERS)
  • OFFSET 6" WATER MAIN (BY OTHERS)
  • CONSTRUCT NEW RAMPS PER FDOT INDEX 522‑002
  • EX. CONC. SIDEWALK TO BE REMOVED AND REPLACED (IN AREA SHOWN HATCHED)
  • CONNECT TO EX. STORMWATER MANHOLE D‑18
  • CAUTION (callout on profile near ex. 2" gas / VCP crossings)
  • Profile scale: 1" = 2' VERT. / 1" = 20' HORIZ.; plan graphical scale 1" = 20"

Every line on the sheet is typed by what it is: a structure callout, a station, an invert value, a utility witness tag, a proposed or existing note. That is what makes an annotation addressable rather than merely readable. Hover a row to light every instance of that type on the sheet.

Annotation typeCountExample
Structure callout39V-1033
Station1324+00
Proposed work callout33PROP. 23 LF OF 12" X 18" ERCP
Existing condition callout33EX. CONC. SIDEWALK TO BE
Invert or rim value53INV. 15" RCP ELEV. 6.25(E)
Pipe or utility spec278" VCP Wastewater
Utility witness tag194VVHI #117
Spot elevation127110.50
Note or long string5OFFSET 6" WATER MAIN (BY OTHERS)
Other lettering681OFFSET 6" WATER (BY OTHEI

Surveyed symbols found on this sheet, named by the set's own legend. Hover a class to light every instance at once. Counts are reported as found, never adjusted to match an expectation.

Legend classCount
iron pipe17
water valve cover15
shared utility pole11
drainage manhole10
water meter10
telephone pedestal7
reclaimed water valve cover4
post4
sanitary manhole3
fire hydrant2
single support sign2
gas regulator1
iron rod1

Every instance, with the callouts printed beside it

Each located symbol, and the text on the sheet within reach of it, nearest first. Distances are real feet at the sheet scale, not pixels. Where a callout carries an identifier that names this kind of feature, it is promoted to ID; proximity alone does not establish labelling, agreement does. Hover a row to zoom to that symbol.

SymbolStationIDCallouts within reach
shared utility pole24+00.20·24+00
post24+00.53·24+00
single support sign24+01.49·G  24+00  13.33
shared utility pole24+02.01·24+00  G  6"WM
post24+02.78·24+00
iron rod24+04.25·13.33  G  6"WM
iron pipe24+04.87·X  CAS(D)
shared utility pole24+10.39·CAS(D)
water valve cover24+11.58·6"WM  13.33  G
iron pipe24+14.44·X
water meter24+34.12·13.02  BT(D)  ST-8
water meter24+43.83·13.56  13.68  13.32
telephone pedestal24+45.84·ST-9  CAS(B)  RCW
drainage manhole24+53.89·ST-10  S  BT(B)
water meter24+55.10·W  13.66  ST-8
water meter24+59.83·W  13.66  G
iron pipe24+73.26·12.8  CAS(B)  13.14
shared utility pole24+82.41·BT(B)  13.67  +13.9
telephone pedestal24+85.88·+13.9  25+00  BT(B)
gas regulator24+88.00·G  6"WM  WM
water valve cover24+94.74V-103313.16  8.78  V-1033
sanitary manhole24+96.45·WM  6"WM
water valve cover24+96.25VVH#116VVH#116  S  VVH #117
water valve cover24+96.80VVH#114VVH#114  VVH#112  V-1033
water valve cover24+98.66VVH#114VVH#114  VVH#112  V-1033
water valve cover25+02.18VVH #117VVHI #117  VVH #117  VVH#116
water valve cover25+03.24VVH#112VVH#112  VVH#114  V-1033
water valve cover25+03.59V-1033V-1033
iron pipe25+06.81·25+00  G  BT(B)
iron pipe25+08.62·V-1033  ST-12  VVH#116
iron pipe25+25.66·ST-12  Ex. Frontier
drainage manhole25+30.99·ST-13  12.8  BT(B)
water meter25+41.86·W  1.4  16.4
water meter25+45.58·W  1.4  16.4
single support sign25+47.90·W  1.4  16.4
iron pipe25+95.43·+14.22  G  13.44
iron pipe26+13.33·2.87  13.15  BT(B)
water valve cover26+25.60·W  OHL  BT(B)
water meter26+25.60·W  OHL  BT(B)
iron pipe26+36.97·12.86  12.43
telephone pedestal26+58.55·G  BT(D)
iron pipe26+60.61·15.08  G
iron pipe26+76.36·nothing within reach
shared utility pole26+81.04·BT(B)
reclaimed water valve cover26+84.61·BT(B)  OHL
shared utility pole26+85.82·W  G  27+00
shared utility pole26+87.48·W  27+00  G
iron pipe26+88.89·27+00  W
iron pipe26+92.61·nothing within reach
iron pipe26+94.87·X  +11.2  Ex. 6" Water
water valve cover27+10.85·+12.1  +12.7  SL-4
telephone pedestal27+12.62·27+00  ST-14  +12.7
drainage manhole27+12.97·ST-15  BT(B)  S
post27+35.00·ST-14
drainage manhole27+38.32D-18D-18  OHL  BT(8)
telephone pedestal27+39.48·RCW  V-11  2' Curb And Gutter
water valve cover27+53.21V-11V-11  BT(B)  Ex
drainage manhole27+59.55D-17D-17  10.85  10.41
reclaimed water valve cover27+62.17V-11BT(B)  V-11  15" RCP
shared utility pole27+90.12·BT(B)  X  Ex. 18" RCP
fire hydrant27+90.78·X  BT(B)  Ex. 18" RCP
water meter27+94.10·W  28+00  G
shared utility pole28+01.69·BT(B)  D-22  Ex. 23"x 14" ERCP.
water meter28+03.65·W  D-20  G
reclaimed water valve cover28+05.11·RCW  +10.4  9.08
shared utility pole28+05.21·D-22  D-23  Ex. 23"x 14" ERCP.
reclaimed water valve cover28+05.36·RCW  W  9.08
water meter28+05.67·W  D-20  G
drainage manhole28+07.53·+12.8  12.03  12.25
telephone pedestal28+08.73·9.08  RCW  9.68
telephone pedestal28+11.25·9.08  9.68  9.99
water valve cover28+11.60·28+00  RCW  OHL
drainage manhole28+18.09D-22D-22  G  S
drainage manhole28+18.09D-2376.78  12.03  D-23
sanitary manhole28+25.38S-7S  S-7  BT(B)
sanitary manhole28+25.59S-8S  S-8  S-7
drainage manhole28+40.98·+12.8  V-16  Ex. 15" VCP Wastewater
iron pipe28+42.59·nothing within reach
water valve cover28+45.51V-14V-14  W  6" WM
fire hydrant28+47.62·V-14  W  V-15
drainage manhole28+48.98·Ex. 15" VCP Wastewater
water valve cover28+52.25V-16V-16  +11.6
shared utility pole28+55.97·+11.6  V-16  Ex. 15
water valve cover28+57.38V-15V-15  Ex. 15  VCP
post28+59.39·V-15  Ex. 15  11.08
iron pipe29+61.06·18.52
iron pipe29+61.83·0.63  10.5  W

1,205 lines read from this sheet, including rotated title block lettering. The 400 longest are listed here. Hover a row to zoom to it on the sheet.

TextConfidenceType
OFFSET 6" WATER MAIN (BY OTHERS)0.986Note or long string
Stormwater Engineering Division1.0Note or long string
D-18 CONNECT TO EX. STORMWATER0.989Note or long string
PROP. 23 LF OF 12" X 18" ERCP0.955Proposed work callout
PROP. 23 LF OF 12"X 18" ERCP0.99Proposed work callout
OFFSET 6" WATER (BY OTHERS)0.987Note or long string
CONNECT TO EX. MANHOLE D-180.99Note or long string
INV. 15" RCP ELEV. 6.25(E)0.975Invert or rim value
INV. 18" RCP ELEV. 6.00(N)0.988Invert or rim value
INV. 18" RCP ELEV. 6.00(S)0.964Invert or rim value
INV. 15" RCP ELEV. 6.00(W)0.963Invert or rim value
18" RCP INV. ELEV. 5.88(S)0.972Invert or rim value
OFFSET 6" WATER (BY OTHEI0.976Other lettering
INV. 12"× 18" RCP 6.75(S)0.962Invert or rim value
INV. 12"x 18” RCP 6.75(S)0.959Invert or rim value
EX. CONC. SIDEWALK TO BE0.983Existing condition callout
PROP. STORMWATER MANHOLE0.994Proposed work callout
PROP. STORMWATER MANHOLE0.997Proposed work callout
PROP. STORMWATER MANHOLE0.998Proposed work callout
OFFSET 6"WATER MAIN (BY0.988Other lettering
PROP. 182 LF OF 18" RCP0.971Proposed work callout
(IN AREA SHOWN HATCHED)0.98Other lettering
PROP. 54 LF OF 18" RCP0.99Proposed work callout
PROP. 20 LF OF 15" RCP0.971Proposed work callout
PROP. 77 LF OF 18" RCP0.975Proposed work callout
PROP. 18 LF OF 15" RCP0.987Proposed work callout
PER FDOT INDEX 522-0020.996Other lettering
PROP. 41 LF OF 15" RCP0.977Proposed work callout
Ex. 15" VCP Wastewater0.955Existing condition callout
EX. GUTTER ELEV. 13.400.971Existing condition callout
WOODMERE & LOIS AVENUE0.983Other lettering
PROP.|23 LF OF 18"RCP0.975Proposed work callout
INV. 18" RCP 6.59(SE)0.943Invert or rim value
STA. 24+46.5, 35' RT.0.981Other lettering
INV. 15" RCP 6.75(NW)0.919Invert or rim value
PROP. 18" RCP @ 0.21%0.97Proposed work callout
DRAINAGE IMPROVEMENTS1.0Other lettering
REMOVED AND REPLACED0.997Other lettering
INV. 15” RCP 6.83(E)0.932Invert or rim value
INV. 15" RCP 6.83(E)0.988Invert or rim value
INV. 18" RCP 6.59(N)0.99Invert or rim value
INV. 18” RCP 6.59(N)0.971Invert or rim value
INV. 18” RCP 6.59(S)0.973Invert or rim value
INV. 18" RCP 6.59(S)0.989Invert or rim value
STA. 24+46.5, 35’RT.0.959Other lettering
INV. 18" RCP 6.75(N)0.989Invert or rim value
INV. 18” RCP 6.75(N)0.973Invert or rim value
INV. 18" RCP 6.75(S)0.984Invert or rim value
INV. 18” RCP 6.75(S)0.97Invert or rim value
INV. 15” RCP 9.00(E)0.949Invert or rim value
INV. 15" RCP 9.00(E)0.965Invert or rim value
INV. 15” RCP 6.75(W)0.968Invert or rim value
INV. 15" RCP 6.75(W)0.957Invert or rim value
INV. 18” RCP 7.00(N)0.948Invert or rim value
INV. 18" RCP 7.00(N)0.976Invert or rim value
THROAT ELEV. = 13.400.995Invert or rim value
Ex. FiberOptic Cable0.999Existing condition callout
CONSTRUCT NEW RAMPS0.985Other lettering
Buried Frontier(AL)0.993Other lettering
SL-3 Cohc. Sidewalk0.957Other lettering
Buried Frontier(AL)0.999Other lettering
-8" Reclaimed Water0.951Other lettering
STA. 25+31, 27' RT.0.973Other lettering
PROP. TYPE II INLET0.981Proposed work callout
INV 15” RCP 9.30(W)0.956Invert or rim value
INV 15" RCP 9.30(W)0.975Invert or rim value
STA. 24+54, 27' RT.0.967Other lettering
STA. 24+54, 27’ RT.0.933Other lettering
Ex. Telephone Cable0.999Existing condition callout
STA. 27+13, 27' RT.0.969Other lettering
PROP. TYPE II INLET0.965Proposed work callout
PROP. TYPE I/ INLET0.955Proposed work callout
STA. 24+84, 59' RT.0.969Other lettering
PROP. TYPE II INLET0.965Proposed work callout
PROP. TYPE I/ INLET0.956Proposed work callout
STA. 27+39, 26' RT.0.972Other lettering
STA. 25+07, 59' RT.0.97Other lettering
INV. ELEV. 4.75(NW)0.997Invert or rim value
PROP. 12"X 18" ERCP0.978Proposed work callout
Mobility Department0.999Other lettering
(Per City of Tampa0.994Other lettering
Ex. 23"x 14" ERCP.0.948Existing condition callout
2' Curb And Gutter0.986Invert or rim value
2' Curb And Gutter0.971Invert or rim value
?' Curb And Gutter0.957Invert or rim value
2' Curb And Gutter0.988Invert or rim value
PROP. TYPE I INLET0.971Proposed work callout
STA. 24+46, 7’ RT.0.942Other lettering
STA. 24+46, 7' RT.0.98Other lettering
STA. 25+31, 27’RT.0.939Other lettering
THROAT ELEV. 12.770.988Invert or rim value
PROP. TYPE I INLET0.978Proposed work callout
THROAT ELEV. 12.770.981Invert or rim value
C/L PROPOSED GRADE1.0Other lettering
C/L PROPOSED GRADE1.0Other lettering
STA. 27+13, 5' RT.0.956Other lettering
C/L Existing Grade1.0Other lettering
THROAT ELEV. 11.850.979Invert or rim value
STA. 27+13, 27’RT.0.937Other lettering
STA. 24+84, 59’RT.0.968Other lettering
THROAT ELEV. 13.780.98Invert or rim value
STA. 27+39, 26’RT.0.972Other lettering
STA. 25+07, 59’RT.0.956Other lettering
INV. ELEV. 7.75(E)0.998Invert or rim value
8" VCP Wastewater0.992Pipe or utility spec
STA. 27+13, 5’RT.0.96Other lettering
RIM ELEV. = 14.200.964Invert or rim value
RIM ELEV. = 13.800.992Invert or rim value
PROP. 23 LF OF 10.98Proposed work callout
RIM EL EV 1.3 100.845Invert or rim value
Ex. 600 BT Cable0.998Existing condition callout
PLAN AND PROFILE0.969Other lettering
Buried Frontier0.999Other lettering
SCALE: 1" = 20'0.942Other lettering
SCALE: 1” = 20'0.932Other lettering
RIM ELEV. 13.180.992Invert or rim value
RIM ELEV. 13.120.974Invert or rim value
TOP ELEV. 13.310.992Invert or rim value
RIM ELEV. 12.100.975Invert or rim value
RIM ELEV. 13.100.99Invert or rim value
RIM ELEV. 12.100.966Invert or rim value
RIM ELEV. 12.100.982Invert or rim value
1” = 20' HORIZ.0.916Other lettering
Conc. Sidewalk1.0Other lettering
Conc. Sidewalk1.0Other lettering
Conc. Sidewalk0.999Other lettering
A/VH #113(J(B)0.874Other lettering
PROP. 10 LF OF0.972Proposed work callout
Ex. 1-4" COND.0.954Existing condition callout
Ex. 1-4” COND.0.96Existing condition callout
(nv. 5.88(Ss)0.837Other lettering
DATE: 05/21/250.976Other lettering
4" Conc. Curb0.988Other lettering
-Buried Front0.962Other lettering
4" Conc. Curb0.981Other lettering
4" Conc. Curb0.936Other lettering
ASVHALT AALTY0.675Other lettering
Ex. Telephone0.998Existing condition callout
-4' PVC Fence0.982Pipe or utility spec
-4' Conc. S/W0.963Other lettering
-6' PVC Fence0.95Pipe or utility spec
Wanolasterole0.823Other lettering
PROP. 15" RCP0.968Proposed work callout
PROP. 18" RCP0.967Proposed work callout
PROP. 18" RCP0.975Proposed work callout
Inv. 4.75(NW)0.993Invert or rim value
PROP. 18" RCP0.968Proposed work callout
PROP. 18" RCP0.966Proposed work callout
(nv. 5.88(Ss)0.834Other lettering
(nv. 5.88(S)0.752Other lettering
1” = 2' VERT.0.928Other lettering
CITY of TAMPA0.963Other lettering
Ex. 6" Water0.943Existing condition callout
Storm Atlas)1.0Other lettering
Ex. 6" Water0.946Existing condition callout
Ex. 6" Water0.974Existing condition callout
-Ex. 18" RCP0.935Pipe or utility spec
HOHRCWCAS(B)0.941Other lettering
Ex. Frontier0.967Existing condition callout
4’ PVC Fence0.946Pipe or utility spec
6' PVC Fence0.969Pipe or utility spec
6’ PVC Fence0.934Pipe or utility spec
PROP. 15"RCP0.986Proposed work callout
6" CIP Water0.998Other lettering
Inv. 7.75(E)0.999Invert or rim value
MANHOLE D-180.968Other lettering
PROP. 18"RCP0.991Proposed work callout
PROP. 18"RCP0.967Proposed work callout
PROP. 18"RCP0.999Proposed work callout
6.59 (N 8 5)0.822Other lettering
V. EL 59 SE)0.668Other lettering
1ot 77 250.632Other lettering
(nv. 5.88(s)0.814Other lettering
PROFILE VIEW0.997Other lettering
F OF 18"RCP0.984Pipe or utility spec
ATLAS I - 90.914Other lettering
Hedge Fence1.0Other lettering
Ex. 15" VCP0.962Existing condition callout
Ex. 15” VCP0.939Existing condition callout
——Conc. S/W0.938Other lettering
dN00°48'12"0.818Other lettering
N00°48'12"E0.985Other lettering
Ex. 18” RCP0.917Existing condition callout
=+RCWCAS(B)0.89Other lettering
RCONSCAS(B)0.772Other lettering
LOHRCWAS(B)0.745Other lettering
-Ex. 2" Gas0.955Other lettering
RESIDENTIAL1.0Other lettering
-16.6916.710.952Other lettering
Ex. 18" RCP0.937Existing condition callout
EROQ TINLE0.648Other lettering
8" RC Water0.961Other lettering
Ex. 15" RCP0.963Existing condition callout
Ex. 18" RCP0.981Existing condition callout
Ex. 18” RCP0.913Existing condition callout
NV.00 8 S)0.731Other lettering
NV. E 8 S)0.717Other lettering
V., . (W)0.641Other lettering
V.. (S)0.664Other lettering
= 20 HORIZ.0.951Other lettering
SW 2023-140.981Other lettering
CONC. WALK0.962Other lettering
ATLAS 1- 90.956Other lettering
Ex. 4" Gas0.952Existing condition callout
Conc. Curb0.959Other lettering
Wastewater1.0Other lettering
Conc. Curb0.999Other lettering
218)5V0RCW0.705Other lettering
Cable (AL)0.997Other lettering
16.6016.710.973Other lettering
4' Conc. S0.932Other lettering
(TYPE "J")0.98Other lettering
(TYPE "J")0.957Other lettering
Ex. 6" WM-0.887Existing condition callout
Wastewater1.0Other lettering
Ex. 8" VCP0.893Existing condition callout
Ex. 2" Gas0.933Existing condition callout
Fiberoptic1.0Other lettering
V. 8 S)0.718Other lettering
V 6 75 (NW0.62Other lettering
nv. 5.8(s)0.887Other lettering
= 2’ VERT.0.94Other lettering
20’ HORIZ.0.922Other lettering
Conc. D/w0.864Other lettering
(Retired)0.95Other lettering
Conc. D/W1.0Other lettering
OH(-BT(D)0.898Other lettering
Conc. D/W0.949Other lettering
- - BT(B)0.815Other lettering
- - BT(B)0.804Other lettering
上(80A3(B)0.794Other lettering
onc. Curb0.996Other lettering
Conc. D/w0.872Other lettering
VVHI #1170.931Utility witness tag
ONE STORY1.0Other lettering
PLAN VIEW0.998Other lettering
Conc. D/W0.999Other lettering
Ex. 6" WM0.935Existing condition callout
Ex. 6” WM0.927Existing condition callout
TOP 11.200.998Other lettering
TOP 10.851.0Other lettering
TOP 10.800.999Other lettering
TOP 10.401.0Other lettering
Reclaimed1.0Other lettering
Ex. 6" WM0.945Existing condition callout
TOP 10.190.999Other lettering
PROP. 12'0.97Proposed work callout
V. 8 S)0.683Other lettering
V E 59 S)0.664Other lettering
. E 75(N)0.673Other lettering
V.. ()0.586Other lettering
V . 5 S)0.628Other lettering
REVISIONS1.0Other lettering
REVISIONS1.0Other lettering
(×2)(AL)0.961Other lettering
Frontier1.0Other lettering
000000000.544Other lettering
000000000.638Other lettering
BT(B (()0.575Other lettering
BT(B).730.849Other lettering
-OHAS(B)0.79Other lettering
1-4"COND0.941Other lettering
yVH #1150.937Other lettering
1. 2..380.668Other lettering
DRIVEWAY1.0Other lettering
DRIVEWAY1.0Other lettering
VVH #1170.966Utility witness tag
13.22 210.788Other lettering
Brick D/0.999Other lettering
STA 4+930.736Other lettering
L= 33.170.901Other lettering
L= 13.010.864Other lettering
ÉL= 3.010.854Other lettering
JQP 9.760.939Other lettering
TOP 9.760.998Other lettering
TOP 5.640.999Other lettering
V (N)0.722Other lettering
V. (N)0.76Other lettering
V. E ()0.667Other lettering
V. 7 ()0.65Other lettering
V. E)0.655Other lettering
PLAN ANI0.997Other lettering
-(0)18H0.91Other lettering
- BT(D)0.911Other lettering
- BT(B)0.818Other lettering
WPHK1080.713Other lettering
72 BFOT0.974Pipe or utility spec
_S BT(B0.875Other lettering
- BT(B)0.922Other lettering
-BT(B)-0.926Other lettering
15" RCP0.904Pipe or utility spec
- BT(B)0.936Other lettering
VVH#1120.977Utility witness tag
− BT(B)0.767Other lettering
AVH#1130.981Other lettering
二-BT(B)0.757Other lettering
- BT(B)0.9Other lettering
(A)S(8)0.779Other lettering
RASW(W)0.606Other lettering
VVH#1140.957Utility witness tag
ROWABSE0.508Other lettering
CAST(8)0.664Other lettering
RCAW(B)0.976Other lettering
- BT(B)0.849Other lettering
− BT(B)0.923Other lettering
- BT(B)0.784Other lettering
T (8) -0.55Other lettering
− ( _ 0.568Other lettering
- 8T(B)0.872Other lettering
1.82.380.703Other lettering
ASPHALT1.0Other lettering
3.0' Dp0.974Other lettering
PULLBOX1.0Other lettering
ASPHALT1.0Other lettering
VVH#1160.997Utility witness tag
3.0' Dp0.993Other lettering
Cluster1.0Other lettering
ondi i0.648Other lettering
idewalk0.817Other lettering
sidewak0.787Other lettering
O OOOLE0.699Other lettering
ST-- 130.775Other lettering
L= 3.170.769Other lettering
VVH-1080.991Utility witness tag
VVH-1170.982Utility witness tag
VWH-1140.944Other lettering
VVH-1140.996Utility witness tag
VWH-1120.934Other lettering
-Ex. 8"0.941Other lettering
VVH-1120.991Utility witness tag
VVH-1160.995Utility witness tag
72 BFOT0.976Pipe or utility spec
VVH-1150.989Utility witness tag
8.66(E)1.0Other lettering
CAUTION1.0Other lettering
VVH-1130.995Utility witness tag
@ 0.34%0.991Other lettering
@ 0.35%0.996Other lettering
@ 0.52%0.994Other lettering
V (Nw0.617Other lettering
@ 0.93%0.988Other lettering
59S)0.622Other lettering
V.E 1 W0.586Other lettering
V7 5 (N0.678Other lettering
@ 0.32%0.992Other lettering
ot 250.679Other lettering
— RCW-0.841Other lettering
110.500.956Spot elevation
+10.500.982Spot elevation
2' SRF0.947Other lettering
PULLBO1.0Other lettering
ULLBOX0.999Other lettering
-11.010.925Spot elevation
Ex. 4'0.973Existing condition callout
- RCW-0.904Other lettering
-11.010.928Spot elevation
-55WBF0.9Other lettering
Buried1.0Other lettering
2' SRF0.926Other lettering
5' WBF0.918Other lettering
BT(B) 0.837Utility witness tag
BT(B8)0.796Other lettering
-BT(D)0.898Other lettering
-BT(B)0.687Other lettering
B8r(8)0.528Other lettering
+13.360.922Spot elevation
WH#1080.975Other lettering
Ex. 150.973Existing condition callout
- BT()0.827Other lettering
BT(BC60.864Other lettering
=BT(B)0.949Other lettering
T(B)P)0.795Other lettering
CAS(B)0.999Utility witness tag
CAS(B)0.888Utility witness tag
CAS(B)0.888Utility witness tag
CAS(B)1.0Utility witness tag
(0S(8)0.673Other lettering
CAS(B)1.0Utility witness tag
CAS(D)1.0Utility witness tag
CAS(B)0.84Utility witness tag
CAS(B)0.999Utility witness tag
−BT(B)0.917Other lettering
RGyWsM0.614Other lettering
CAS(B)1.0Utility witness tag
CAS(B)1.0Utility witness tag
BBT)B80.588Other lettering
CAS(B)0.941Utility witness tag
600 BT0.861Other lettering
V-10330.852Structure callout
+14.220.973Spot elevation
− B _0.513Other lettering
BT(B) 0.926Utility witness tag
ATH IN0.744Other lettering
AT INE0.759Other lettering
70'(P)0.99Other lettering
3.0'Dp0.952Other lettering
2.1'Dp0.962Other lettering
HORTIO0.9Other lettering
+16.620.97Spot elevation
+16.590.998Spot elevation

The sheet as continuous text, in the order a person would read it. Note columns become prose, printed tables stay tables.

SW 2023-14

PLOT DATE: Tuesday, May 27, 2025

PROFILE VIEW

No.DATEREVISIONS
3
2
1
No.DATEREVISIONS
6
5
4

DES: SEB DRN: BB CKD: JDM DATE: 05/21/25

CITY of TAMPA Mobility Department Stormwater Engineering Division

WOODMERE & LOIS AVENUE DRAINAGE IMPROVEMENTS PLAN AND PROFILE

SHEET 5 OF 9

Every printed table on this sheet, recovered as rows and cells.

Revision block

DATEREVISIONSNo.DATEREVISIONSDE
36DR
25CK
Sheet
6 of 9 civil
Text lines
187 each located on the sheet
Symbols
0 0 classes
Viewports
3 titled drawings found

WOODMERE & LOIS AVENUE CROSS-SECTIONS PLAN SHEET

This sheet provides two north-looking cross-section views (SL-1 at STA. 21+00 and SL-2 at STA. 23+20) of the proposed stormwater drainage alignment along the Woodmere & Lois Avenue corridor. It instructs the contractor to install new drainage pipes and structures (labeled ST-2 through ST-7) at the indicated offsets and elevations within the right-of-way. Each section also maps existing utilities (gas, water, RCW, fiber optic, buried cable, condenser) and existing grade to be cleared or protected, with CAUTION clouds flagging areas of conflict.

Viewports

TitleKindScaleContents
PLAN VIEW SHEET 5 (sheet header)title/captionnoneCentered header text identifying the sheet as the fifth plan-view sheet of the set.
CROSS SECTION SL-1 LOOKING NORTH @ STA. 21+00section1" = 2' VERT., 1" = 20' HORIZ. (shared scale note at right of sheet)A north-looking horizontal cross section on a 0–22 offset grid. Shows R/W and E/P lines, 'Ex. Grade @ Propose Main', drainage structures ST-2, ST-4, ST-3, existing utilities (Ex. 4" Gas, Ex. 8" WM, Ex. 6" WM, Buried 200 & 400BT Frontier(L), Ex. 2" Gas, Ex. 600 BT, (2)1-4" COND, Ex. 8" RCW, Ex. 26 BT(L5), Ex. 72 BFOT, Ex. 30" RCW), proposed pipe 'PROP. 12" x 18" ERCP' and 'PROP. 18" RCP', and a CAUTION cloud.
CROSS SECTION SL-2 LOOKING NORTH @ STA. 23+20section1" = 2' VERT., 1" = 20' HORIZ. (shared scale note at right of sheet)A north-looking horizontal cross section on a 0–22 offset grid. Shows R/W, E/P and S/W lines, 'Ex. Grade @ Propose Main', drainage structures ST-5, ST-7, ST-6, 'OFFSET 6" WM' / 'Ex. 6" Water', existing utilities (Ex. 600 BT, Ex. FiberOptic Cable, Ex. 2" Gas, Ex. 8" RCW, Ex. 8" VCP Inv. El. 9.45(N)), proposed pipe 'PROP. 28LF OF 12"x18" ERCP @.07%', 'PROP. 5LF OF 15" RCP CLIV @ .12%', 'PROP. 18" RCP', and a CAUTION cloud.

Quantities this sheet can support

linear feet of 12" x 18" ERCP (e.g. 28 LF shown in SL-2)linear feet of 18" RCPlinear feet of 15" RCP (5 LF shown in SL-2)count of drainage structures (ST-2, ST-3, ST-4, ST-5, ST-6, ST-7)existing utility pipe diameters/counts (e.g. Ex. 30" RCW, Ex. 8" RCW, Ex. 6"/8" WM, Ex. 4"/2" Gas, Ex. 600 BT, Ex. FiberOptic Cable, Buried 200 & 400BT Frontier, (2)1-4" COND, Ex. 26 BT(L5), Ex. 72 BFOT, Ex. 8" VCP)offset grid positions (0–22) for locating structures and pipes

Key notes read from the sheet

  • Two 'CAUTION' clouds appear, one in each cross section, flagging utility/structure conflict areas.
  • Proposed slopes given as percentages: 'PROP. 28LF OF 12"x18" ERCP @.07%' and 'PROP. 5LF OF 15" RCP CLIV @ .12%'.
  • Scale note: '1" = 2' VERT.' and '1" = 20' HORIZ.'
  • Sections labeled 'LOOKING NORTH' at STA. 21+00 and STA. 23+20.
  • Existing utilities are marked 'Ex.' (e.g. 'Ex. Grade @ Propose Main', 'Ex. FiberOptic Cable', 'Ex. 8" VCP Inv. El. 9.45(N)') and are to be protected/verified.
  • Title block: City of Tampa, Mobility Department, Stormwater Engineering Division; DES: SEB, DRN: JDM, CKD: JDM, DATE: 05/21/25; project ID 'SW 2023-14'.

Every line on the sheet is typed by what it is: a structure callout, a station, an invert value, a utility witness tag, a proposed or existing note. That is what makes an annotation addressable rather than merely readable. Hover a row to light every instance of that type on the sheet.

Annotation typeCountExample
Structure callout5ST-3
Proposed work callout8PROP. 28LF OF 12"x 18" ERCP
Existing condition callout19Ex. Grade @ Propose Main
Invert or rim value2Inv. EI. 9.45(N)
Pipe or utility spec2OFFSET 6" WM
Utility witness tag5RCW
Note or long string1Stormwater Engineering Division
Other lettering145WOODMERE & LOIS AVENUE

Surveyed symbols found on this sheet, named by the set's own legend. Hover a class to light every instance at once. Counts are reported as found, never adjusted to match an expectation.

Legend classCount
None detected on this sheet.

Every instance, with the callouts printed beside it

Each located symbol, and the text on the sheet within reach of it, nearest first. Distances are real feet at the sheet scale, not pixels. Where a callout carries an identifier that names this kind of feature, it is promoted to ID; proximity alone does not establish labelling, agreement does. Hover a row to zoom to that symbol.

SymbolStationIDCallouts within reach
None.

187 lines read from this sheet, including rotated title block lettering. The 400 longest are listed here. Hover a row to zoom to it on the sheet.

TextConfidenceType
Stormwater Engineering Division1.0Note or long string
PROP. 28LF OF 12"x 18" ERCP0.984Proposed work callout
Ex. Grade @ Propose Main0.984Existing condition callout
Ex. Grade @ Propose Main0.984Existing condition callout
WOODMERE & LOIS AVENUE1.0Other lettering
PROP. 5LF OF 15" RCP0.977Proposed work callout
PROP. 12" X 18" ERCP0.956Proposed work callout
Buried 200 & 400BT-0.993Other lettering
PROP. 12"x 18" ERCP0.962Proposed work callout
PROP. 12"X 18" ERCP0.931Proposed work callout
Mobility Department0.999Other lettering
CROSS SECTION SL-11.0Other lettering
CROSS SECTION SL-21.0Other lettering
IERE & LOIS AVENUE0.979Other lettering
PLAN VIEW SHEET 50.988Other lettering
Inv. EI. 9.45(N)0.963Invert or rim value
Inv. E1. 9.45(N)0.982Invert or rim value
LOOKING NORTH @1.0Other lettering
LOOKING NORTH @0.996Other lettering
1” = 20’ HORIZ.0.943Other lettering
1” = 20' HORIZ.0.926Other lettering
Ex. FiberOptic0.994Existing condition callout
Ex. FiberOptic0.989Existing condition callout
CROSS-SECTIONS1.0Other lettering
DATE: 05/21/250.999Other lettering
Ex. 26 BT(LS)0.996Existing condition callout
PROP. 18" RCP0.947Proposed work callout
CROSS SECTIOI0.999Other lettering
1” = 2' VERT.0.944Other lettering
CITY of TAMPA0.966Other lettering
OFFSET 6" WM0.975Pipe or utility spec
Ex. 6" Water0.967Existing condition callout
Frontier(AL)1.0Other lettering
(2)1-4” COND0.937Other lettering
PROP. 18"RCP0.989Proposed work callout
-Ex. 2" Gas0.929Other lettering
OFFSET 6"WM0.972Pipe or utility spec
Ex. 72 BFOT0.998Existing condition callout
PROP.18"RCP1.0Proposed work callout
CLIV @ .12%0.938Other lettering
Ex. 30" RCW0.966Existing condition callout
SW 2023-141.0Other lettering
Ex. 4" Gas0.971Existing condition callout
Ex. 600 BT0.977Existing condition callout
Ex. 600 BT0.998Existing condition callout
Ex. 600 BT0.995Existing condition callout
Ex. 8" VCP0.92Existing condition callout
Ex. 8” VCP0.897Existing condition callout
STA. 21+000.953Other lettering
STA. 23+200.987Other lettering
PLAN SHEET0.999Other lettering
Ex. 8" WM0.964Existing condition callout
Ex. 6" WM0.941Existing condition callout
Ex. 8"RCW0.936Existing condition callout
CLIV@.12%0.999Other lettering
ot 0250.715Other lettering
REVISIONS1.0Other lettering
REVISIONS1.0Other lettering
CAUTION1.0Other lettering
OEx. 2”0.851Other lettering
CAUTION1.0Other lettering
Ex. 2"0.912Existing condition callout
Ex. 8"0.937Existing condition callout
- RCW-0.916Other lettering
SCALE:1.0Other lettering
ot 1250.712Other lettering
ST--60.819Other lettering
Cable1.0Other lettering
Cable1.0Other lettering
@.07%1.0Other lettering
-RCW-0.924Other lettering
- RCW0.946Other lettering
SHEET1.0Other lettering
ST-30.896Structure callout
ST-40.869Structure callout
ST-10.901Structure callout
9--60.811Other lettering
ST-50.881Structure callout
ST-70.819Structure callout
====0.727Other lettering
RCW-0.799Other lettering
DATE1.0Other lettering
DATE1.0Other lettering
DES:1.0Other lettering
DRN:1.0Other lettering
CKD:1.0Other lettering
OF 90.995Other lettering
R/W0.997Other lettering
R/W0.973Other lettering
R/W0.985Other lettering
R/W0.987Other lettering
E/P1.0Other lettering
E/P0.999Other lettering
C/F0.85Other lettering
E/P1.0Other lettering
E/P1.0Other lettering
S/W0.997Other lettering
Gas1.0Other lettering
RCW1.0Utility witness tag
=::0.553Other lettering
RCW1.0Utility witness tag
RCW1.0Utility witness tag
RCW1.0Utility witness tag
RCW1.0Utility witness tag
No.1.0Other lettering
Vo.0.889Other lettering
No.1.0Other lettering
SEB1.0Other lettering
JDM1.0Other lettering
JDM1.0Other lettering
220.883Other lettering
221.0Other lettering
221.0Other lettering
221.0Other lettering
RW0.997Other lettering
200.949Other lettering
201.0Other lettering
201.0Other lettering
201.0Other lettering
181.0Other lettering
181.0Other lettering
180.999Other lettering
181.0Other lettering
161.0Other lettering
161.0Other lettering
161.0Other lettering
161.0Other lettering
141.0Other lettering
141.0Other lettering
141.0Other lettering
141.0Other lettering
121.0Other lettering
120.999Other lettering
120.999Other lettering
120.999Other lettering
100.992Other lettering
100.993Other lettering
100.981Other lettering
100.991Other lettering
II0.851Other lettering
IF0.757Other lettering
W-0.918Other lettering
990.999Other lettering
Yo0.622Other lettering
二0.808Other lettering
一0.537Other lettering
二0.682Other lettering
10.696Other lettering
二0.867Other lettering
00.997Other lettering
81.0Other lettering
80.999Other lettering
81.0Other lettering
81.0Other lettering
I0.613Other lettering
U0.749Other lettering
61.0Other lettering
61.0Other lettering
61.0Other lettering
61.0Other lettering
O0.63Other lettering
O0.586Other lettering
O0.586Other lettering
O0.63Other lettering
41.0Other lettering
41.0Other lettering
41.0Other lettering
41.0Other lettering
A0.836Other lettering
21.0Other lettering
21.0Other lettering
21.0Other lettering
21.0Other lettering
00.994Other lettering
00.996Other lettering
00.997Other lettering
00.997Other lettering
90.998Other lettering
90.965Other lettering
31.0Other lettering
60.998Other lettering
90.991Other lettering
61.0Other lettering
21.0Other lettering
51.0Other lettering
11.0Other lettering
41.0Other lettering

The sheet as continuous text, in the order a person would read it. Note columns become prose, printed tables stay tables.

Plan View Sheet 5

CROSS SECTION SL-1 LOOKING NORTH @ STA. 21+00

CROSS SECTION SL-2 LOOKING NORTH @ STA. 23+20

SCALE: 1" = 2' VERT. 1" = 20' HORIZ.

No.DATEREVISIONS
3
2
1
No.DATEREVISIONS
6
5
4

DES: SEB DRN: JDM CKD: JDM DATE: 05/21/25

CITY of TAMPA Mobility Department Stormwater Engineering Division

WOODMERE & LOIS AVENUE CROSS-SECTIONS PLAN SHEET

SHEET 6 OF 9

Every printed table on this sheet, recovered as rows and cells.

Revision block

DE.
Sheet
7 of 9 civil
Text lines
172 each located on the sheet
Symbols
0 0 classes
Viewports
3 titled drawings found

WOODMERE & LOIS AVENUE CROSS-SECTIONS PLAN SHEET

This sheet provides two separate north‑looking stormwater cross‑sections (SL‑3 at STA. 24+30 and SL‑4 at STA. 26+91) along the Woodmere & Lois Avenue alignment. It directs the contractor to lay out proposed reinforced concrete pipe (RCP) mains—15 in, 18 in, and a 12 in×18 in oval/circular‑oval section—along with their associated manholes/inverts, while locating and avoiding a range of existing underground utilities. The sheet also calls out existing grade at the proposed main and flags an offset to an existing 6 in water main that must be accommodated.

Viewports

TitleKindScaleContents
CROSS SECTION SL‑3 LOOKING NORTH @ STA. 24+30section1" = 2' VERT. / 1" = 20' HORIZ.Left half of the sheet. A gridded cross‑section (vertical axis numbered 0–22 on both sides) showing the proposed 15" RCP and 18" RCP mains and a 12"×18" RCP section, manhole bells with invert/pipe markings (8.55, 6.5, 9.5, 8.15), existing grade at the proposed main, and a cluster of existing utilities including Ex. 4" Gas (Retired), Ex. 400 BT, Ex. 26 BT, Ex. 72 BFOF, Ex. 8" VCP, Ex. 2" Gas, Ex. 1‑4" Conduit, Ex. 8" RCW, Ex. 600 BT, Ex. 26 BT, with R/W, E/P, and S/W survey markers above and a 'CAUTION' cloud.
CROSS SECTION SL‑4 LOOKING NORTH @ STA. 26+91section1" = 2' VERT. / 1" = 20' HORIZ.Right half of the sheet. A gridded cross‑section (vertical axis 0–22) showing proposed 15" RCP and 18" RCP mains with manholes (11.25, 11.55), existing grade at the proposed main, an 'OFFSET EX. 6" WM' callout over the existing 6" WM, and existing utilities including Ex. 4" Gas (Retired), Ex. 8" SS, Ex. 2" Gas, Ex. BT, Ex. 8" RCW, and Ex. BT, with R/W, E/P, and S/W markers above.
SCALElegend blocknonePrinted scale note applying to the cross‑sections: 'SCALE: 1" = 2' VERT. / 1" = 20' HORIZ.' located at the lower right of the drawing area.

Quantities this sheet can support

Linear feet of proposed 15 inch RCPLinear feet of proposed 18 inch RCPLinear feet of proposed 12 inch x 18 inch RCPCount of manholes / drainage structures (with invert elevations)Linear feet / offset of existing 6 inch water main to be relocatedCount and size of existing underground utilities (gas, BT, VCP, RCW, conduit, SS)

Key notes read from the sheet

  • Header at top center reads 'PLAN VIEW SHEET 6' (note the sheet is numbered 7 of 9 in the title block).
  • Project/drawing reference 'SW 2023-14' appears in the upper right.
  • A 'CAUTION' cloud is shown over the dense existing‑utility cluster in section SL‑3.
  • 'OFFSET EX. 6" WM' is called out in section SL‑4, indicating the existing 6 inch water main is offset from its original position.
  • 'Ex. Grade @ Propose Main' is annotated in both sections to tie the existing ground to the proposed main.
  • Both sections are labeled 'LOOKING NORTH' at their respective stations (STA. 24+30 and STA. 26+91).
  • Title block identifies City of Tampa, Mobility Department, Stormwater Engineering Division; design SEB / DRN JDM / CKD JDM; date 05/21/25; revision block (rev 1–5) blank.
  • Scale note: '1" = 2' VERT. / 1" = 20' HORIZ.'

Every line on the sheet is typed by what it is: a structure callout, a station, an invert value, a utility witness tag, a proposed or existing note. That is what makes an annotation addressable rather than merely readable. Hover a row to light every instance of that type on the sheet.

Annotation typeCountExample
Structure callout2ST-14
Station15+91
Proposed work callout9PROP. 12"x18" RCP
Existing condition callout21Ex. 1-4" Conduit
Pipe or utility spec2OFFSET EX. 6" WM
Note or long string1Stormwater Engineering Division
Other lettering136WOODMERE & LOIS AVENUE

Surveyed symbols found on this sheet, named by the set's own legend. Hover a class to light every instance at once. Counts are reported as found, never adjusted to match an expectation.

Legend classCount
None detected on this sheet.

Every instance, with the callouts printed beside it

Each located symbol, and the text on the sheet within reach of it, nearest first. Distances are real feet at the sheet scale, not pixels. Where a callout carries an identifier that names this kind of feature, it is promoted to ID; proximity alone does not establish labelling, agreement does. Hover a row to zoom to that symbol.

SymbolStationIDCallouts within reach
None.

172 lines read from this sheet, including rotated title block lettering. The 400 longest are listed here. Hover a row to zoom to it on the sheet.

TextConfidenceType
Stormwater Engineering Division1.0Note or long string
WOODMERE & LOIS AVENUE1.0Other lettering
Mobility Department0.999Other lettering
CROSS SECTION SL-31.0Other lettering
CROSS SECTION SL-41.0Other lettering
IERE & LOIS AVENUE0.979Other lettering
PLAN VIEW SHEET 60.976Other lettering
-Ex. 1-4" Condult0.912Other lettering
—Ex. 1-4" Conduit0.956Other lettering
PROP. 12"x18" RCP0.973Proposed work callout
OFFSET EX. 6" WM0.957Pipe or utility spec
Ex. 1-4" Conduit0.978Existing condition callout
PROP. 12"x18"RCP0.992Proposed work callout
PROP.12 X18 RCP0.968Proposed work callout
LOOKING NORTH @1.0Other lettering
LOOKING NORTH @1.0Other lettering
1” = 20’ HORIZ.0.931Other lettering
1" = 20' HORIZ.0.906Other lettering
@ Propose Main0.999Other lettering
@ Propose Main0.967Other lettering
CROSS-SECTIONS1.0Other lettering
DATE: 05/21/250.996Other lettering
PROP. 15" RCP0.976Proposed work callout
PROP. 18" RCP0.963Proposed work callout
PROP. 15" RCP0.956Proposed work callout
1” = 2’ VERT.0.933Other lettering
1" = 2' VERT.0.944Other lettering
CITY of TAMPA0.966Other lettering
PROP. 15"RCP0.966Proposed work callout
PROP. 18"RCP0.996Proposed work callout
-Ex. 2"|Gas0.888Other lettering
Ex. 72 BFOT0.972Existing condition callout
SW 2023-141.0Other lettering
Ex. 4" Gas0.866Existing condition callout
Ex. 2" Gas0.93Existing condition callout
Ex. 400 BT0.968Existing condition callout
Ex. 4" Gas0.948Existing condition callout
Ex. 8" RCW0.975Existing condition callout
Ex. 8” RCW0.892Existing condition callout
Ex. 600 BT0.996Existing condition callout
Ex. 8" RCW0.907Existing condition callout
Ex. 8" VCP0.949Existing condition callout
STA. 24+300.97Other lettering
STA. 26+910.989Other lettering
PLAN SHEET1.0Other lettering
Ex. Grade0.998Existing condition callout
Ex. Grade0.971Existing condition callout
Ex. 6" WM0.978Existing condition callout
Ex. 6” WM0.905Existing condition callout
Ex. 26 BT0.999Existing condition callout
Ex. 8" SS0.963Existing condition callout
ot 0250.715Other lettering
REVISIONS1.0Other lettering
REVISIONS1.0Other lettering
Reltired0.939Other lettering
PROP 15"0.965Proposed work callout
1A.24+300.984Other lettering
STA.26+90.999Other lettering
CAUTION1.0Other lettering
Retired1.0Other lettering
Retired1.0Other lettering
S8T--80.703Other lettering
Ex. 260.996Existing condition callout
Ex. BT0.999Existing condition callout
Ex. BT0.996Existing condition callout
Ex. BT0.963Existing condition callout
15"RCP0.998Pipe or utility spec
SCALE:1.0Other lettering
ot 1250.712Other lettering
ST-140.938Structure callout
ST-150.896Structure callout
SHEET1.0Other lettering
ST-S0.81Other lettering
6-1S0.737Other lettering
5+910.995Station
DATE1.0Other lettering
DATE1.0Other lettering
DES:1.0Other lettering
DRN:1.0Other lettering
CKD:1.0Other lettering
OF 90.995Other lettering
R/W0.999Other lettering
R/W0.999Other lettering
E/P1.0Other lettering
E/P1.0Other lettering
R/W0.999Other lettering
R/W0.999Other lettering
E/P1.0Other lettering
E/P1.0Other lettering
S/W0.998Other lettering
S/W0.996Other lettering
8-10.78Other lettering
No.1.0Other lettering
Vo.0.889Other lettering
No.1.0Other lettering
SEB1.0Other lettering
JDM1.0Other lettering
JDM1.0Other lettering
221.0Other lettering
221.0Other lettering
221.0Other lettering
221.0Other lettering
200.998Other lettering
201.0Other lettering
201.0Other lettering
201.0Other lettering
181.0Other lettering
180.999Other lettering
181.0Other lettering
181.0Other lettering
I60.709Other lettering
161.0Other lettering
161.0Other lettering
161.0Other lettering
160.999Other lettering
1L0.858Other lettering
140.998Other lettering
IL0.696Other lettering
140.998Other lettering
140.997Other lettering
100.954Other lettering
140.997Other lettering
ST0.979Other lettering
120.864Other lettering
121.0Other lettering
121.0Other lettering
120.999Other lettering
010.904Other lettering
100.994Other lettering
100.987Other lettering
100.989Other lettering
100.979Other lettering
BT1.0Other lettering
—00.83Other lettering
—00.973Other lettering
—00.982Other lettering
7”0.792Other lettering
Yo0.622Other lettering
二0.608Other lettering
90.825Other lettering
00.998Other lettering
20.87Other lettering
80.999Other lettering
81.0Other lettering
80.999Other lettering
81.0Other lettering
10.883Other lettering
61.0Other lettering
61.0Other lettering
61.0Other lettering
61.0Other lettering
70.937Other lettering
41.0Other lettering
41.0Other lettering
41.0Other lettering
41.0Other lettering
21.0Other lettering
21.0Other lettering
21.0Other lettering
21.0Other lettering
00.996Other lettering
00.987Other lettering
00.927Other lettering
00.997Other lettering
90.965Other lettering
31.0Other lettering
60.998Other lettering
71.0Other lettering
21.0Other lettering
51.0Other lettering
11.0Other lettering
41.0Other lettering

The sheet as continuous text, in the order a person would read it. Note columns become prose, printed tables stay tables.

PLAN VIEW SHEET 6

CROSS SECTION SL-3 LOOKING NORTH @ STA. 24+30

CROSS SECTION SL-4 LOOKING NORTH @ STA. 26+91

SCALE: 1" = 2' VERT. 1" = 20' HORIZ.

No.DATEREVISIONS
3
2
1
No.DATEREVISIONS
6
5
4

DES: SEB DRN: JDM CKD: JDM DATE: 05/21/25

CITY of TAMPA Mobility Department Stormwater Engineering Division

WOODMERE & LOIS AVENUE CROSS-SECTIONS PLAN SHEET

SHEET 7 OF 9

Every printed table on this sheet, recovered as rows and cells.

Revision block

No. | DATE | REVISIONS | No. | DATE | REVISIONS | DE.

Sheet
8 of 9 civil
Text lines
950 each located on the sheet
Symbols
131 14 classes
Viewports
6 titled drawings found

WOODMERE & LOIS DRAINAGE IMPROVEMENTS — PAVEMENT RESTORATION PLAN AND DETAIL

This sheet is the pavement‑restoration plan and detail for the Woodmere & Lois stormwater drainage improvements in the City of Tampa. It shows the proposed re‑surfaced (milled and overlaid) pavement along South Lois Ave between STA. 21+00 and STA. 27+45, the proposed stormwater piping and Type BR‑1 stormwater inlets, and a cross‑section detail of the trench/pavement‑restoration construction. It directs the contractor to mill and overlay the pavement, restore the trench zone as pipe zone plus 5', and verify positive drainage and no ponding.

Viewports

TitleKindScaleContents
PLAN VIEW (upper main plan)plan viewSCALE: 1" = 30" (printed scale bar)Plan of the street corridor including WOODMERE RD., SOUTH LOIS AVE., WEST AZELEE ST., W. DALE AVE. and W. HORATIO ST.; station lines 21+00 through 29+00; proposed stormwater piping, proposed areas to be re‑surfaced, curb/gutter, sidewalks, trees, utility markings, a 'LIMITS OF RE‑PROFILING (STA. 21+83 TO STA. 24+93)' note, north arrow 'ATLAS 1-9', and a rectangular callout labeled 'INSET (SEE BELOW)' pointing to the lower‑left enlarged plan.
PLAN VIEW (lower‑left inset)plan view (enlarged inset)SCALE: 1" = 20" (printed scale bar)Enlarged plan of the W. HORATIO ST. / WEST AZELEE / DALE AVE. intersection area showing proposed pipe alignment with depth/elevation markers (e.g. 13.19, 13.34, 13.77, 13.96, 14.37, 14.50, MATCH EX. 14.82, MATCH EX. 12.96), proposed Type BR‑1 stormwater inlets, 60" R/W, 30' E.O.P., 2' C.O.P., and 'PROP. AREA TO BE RE‑SURFACED SEE DETAIL, SHEET X' notes.
Cross‑section detail (lower right)section (typical detail)noneTypical cross‑section of the pavement/trench showing asphalt wearing surface (see table), base course (see table), undisturbed or compacted native soils (TYP), pipe O.D., pipe zone width, pipe zone bedding/backfill, '18" MIN. (TYP)' depths, existing pavement section, existing curb and/or gutter, 'MILLING & OVERLAY LIMITS', and the dimension 'TRENCH PAVEMENT RESTORATION = PIPE ZONE + 5'".'.
Shaded‑area legend blocklegend blocknoneGray swatch with text: 'SHADED AREA REPRESENTS AREA TO BE RE‑SURFACED (STA. 21+00 TO STA. 27+45)'.
PAVEMENT REQUIREMENTS tabletablenoneTable with columns STREET CLASSIFICATION, BASE MATERIAL/THICKNESS (IN.), ASPHALT MATERIAL/THICKNESS (IN.); single row: COLLECTOR / ARTERIAL (II), CRUSHED CONC. / 12", 4".
PAVEMENT RESTORATION NOTES blocknotes/table blocknoneNumbered general notes 1 through 7 governing trenching, bedding/backfill, FDOT construction standards, milling of existing pavement outside the trench zone, gutter‑line/curb‑reveal requirements, ponding review, FDOT §327‑1 milling, and positive drainage.

Quantities this sheet can support

linear feet of re‑surfaced / milled‑and‑overlaid pavement (STA. 21+00 to STA. 27+45)linear feet of proposed stormwater piping (18" typical minimum pipe)count of proposed Type BR‑1 stormwater inletslinear feet of trench pavement restoration (pipe zone + 5')pavement thicknesses (12" crushed concrete base; 4" asphalt wearing course)

Key notes read from the sheet

  • SHADED AREA REPRESENTS AREA TO BE RE‑SURFACED (STA. 21+00 TO STA. 27+45).
  • TRENCH PAVEMENT RESTORATION = PIPE ZONE + 5'".
  • 2. PROVIDE BEDDING AND PIPE BACKFILL WITHIN THE PIPE ZONE AS OTHERWISE REQUIRED.
  • 3. ROAD BASE AND ASPHALT WEARING COURSES SHALL BE CONSTRUCTED IN ACCORDANCE WITH FDOT TRANSPORTATION TECHNICAL STANDARDS.
  • 4. FOR ROADWAY AREA OUTSIDE OF THE TRENCH ZONE, EXISTING ASPHALT PAVEMENT SHALL BE MILLED SUFFICIENT DEPTH TO PROVIDE FOR ASPHALT OVERLAY TO THE LEVEL AND CROSS SLOPES INDICATED.
  • 5.1. CONTRACTOR SHALL REVIEW ROADWAY LONGITUDINAL GRADES PRIOR TO PAVEMENT RESTORATION WORK TO ENSURE THAT NO PONDING GREATER THAN 3/4" DEEP SHALL REMAIN AT A TIME 2 HOURS AFTER THE SURFACE HAS BEEN FLOODED BY A STORM EVENT OR OTHERWISE BY THE CONTRACTOR APPLIED AT A SUFFICIENT RATE TO SATISFY ENGINEER OR HIS DESIGNEE.
  • 6. MILLING AND RESURFACING OPERATIONS SHALL BE PERFORMED IN ACCORDANCE WITH FDOT STANDARD SPECIFICATIONS, SECTION 327‑1 MILLING OF EXISTING ASPHALT PAVEMENT.
  • 7. ENSURE POSITIVE DRAINAGE IS PRESERVED OR IMPROVED ACROSS THE ENTIRE MILLED AND RESURFACED AREA.
  • LIMITS OF RE‑PROFILING (STA. 21+83 TO STA. 24+93).

Every line on the sheet is typed by what it is: a structure callout, a station, an invert value, a utility witness tag, a proposed or existing note. That is what makes an annotation addressable rather than merely readable. Hover a row to light every instance of that type on the sheet.

Annotation typeCountExample
Structure callout1D-21
Station621+00
Proposed work callout8PROP. TYPE BR-1 STORMWATER INLET
Existing condition callout11EXISTING PAVEMENT SECTION
Invert or rim value4SHALL MATCH GUTTER LINE FOR EXISTING CURB/GUTTER STREETS OR
Pipe or utility spec5-6' PVC Fence
Utility witness tag204CAS(D)
Spot elevation78+12.38
Note or long string385. FINISHED ASPHALT SURFACE SHALL MEET CROSS SLOPE INDICATED AND
Other lettering595MILLING & OVERLAY LIMITS

Surveyed symbols found on this sheet, named by the set's own legend. Hover a class to light every instance at once. Counts are reported as found, never adjusted to match an expectation.

Legend classCount
water meter32
iron pipe31
shared utility pole20
water valve cover14
drainage manhole9
single support sign6
telephone pedestal5
reclaimed water valve cover5
fire hydrant4
telephone manhole1
post1
cleanout1
iron rod1
sanitary manhole1

Every instance, with the callouts printed beside it

Each located symbol, and the text on the sheet within reach of it, nearest first. Distances are real feet at the sheet scale, not pixels. Where a callout carries an identifier that names this kind of feature, it is promoted to ID; proximity alone does not establish labelling, agreement does. Hover a row to zoom to that symbol.

SymbolStationIDCallouts within reach
water meter23+71.21·nothing within reach
iron pipe23+74.45·nothing within reach
iron pipe23+77.73·14.29  14.65
water meter23+87.07·14.65  14.29
telephone pedestal24+02.15·21+00
water meter24+05.68·RCW
single support sign24+05.92·nothing within reach
iron pipe24+05.35·14.06  14.26
water meter24+08.20·RCW
shared utility pole24+07.49·RCW
water valve cover24+09.82·nothing within reach
iron pipe24+12.05·13.89  G
shared utility pole24+17.24·14.27
fire hydrant24+20.87·G  W
iron pipe24+26.82·14.27
water valve cover24+27.63·W  RCW
iron pipe24+28.84·14.27
iron pipe24+29.29·14.36  13.82  G
water meter24+32.26·BT(B)  14.36
single support sign24+34.17·W  BFOT(B)
shared utility pole24+38.65·nothing within reach
shared utility pole24+40.46·nothing within reach
water meter24+42.27·nothing within reach
water meter24+41.72·nothing within reach
telephone pedestal24+44.99·G
iron pipe24+45.99·W
water meter24+48.56·G
shared utility pole24+48.81·nothing within reach
telephone pedestal24+51.88·nothing within reach
shared utility pole24+53.39·G
iron pipe24+54.85·13.73  14.08  CAS(B)
drainage manhole24+60.03·nothing within reach
shared utility pole24+65.81·nothing within reach
iron pipe24+81.76·BT(B)  13.54  13.65
single support sign24+83.32·RCW  EX. 14.87  EX.14.87
post24+83.72·RCW  EX. 14.87  EX.14.87
iron pipe24+84.58·13.95  13.89  EXISTING
shared utility pole24+86.69·EXISTING
water meter24+87.39·RCW  BT(B)
water valve cover24+89.00·G
water valve cover24+90.21·13.89  13.95  EXISTING
iron pipe24+90.06·13.89  13.95  EXISTING
iron pipe24+96.55·13.89  EXISTING
single support sign24+99.92·RCW  BT(B)
water meter24+99.97·nothing within reach
iron pipe25+00.87·EXISTING
fire hydrant25+06.96·13.77  8'VCP
iron pipe25+11.98·8'VCP
iron pipe25+13.35·BT(B)  8'VCP  13.77
iron pipe25+14.51·8'VCP  EXISTING
iron pipe25+24.05·8'VCP  EXISTING
iron pipe25+24.05·8'VCP  EXISTING
iron pipe25+33.11·RCW  8'VCP
cleanout25+35.27·W  BT(B)
shared utility pole25+36.12·BT(B)  EXISTING
iron pipe25+39.09·13.19  EXISTING
water meter25+48.60·W  13.77  13.34
telephone pedestal25+50.06·G
drainage manhole25+52.37·S
shared utility pole25+62.08·G
drainage manhole25+65.35·EXISTING
telephone manhole25+68.12·G  EXISTING
shared utility pole25+74.10·G  EXISTING
shared utility pole25+90.10·W
water meter26+11.11·BT(D)
water meter26+17.65·W  BT(D)
drainage manhole26+24.60·BT(B)  CAS(B)  S
water meter26+24.75·BT(D)
water meter26+26.31·BT(B)
water meter26+28.82·BT(D)
water meter26+35.26·nothing within reach
water meter26+35.97·nothing within reach
water valve cover26+44.67·BT(B)
water valve cover26+46.88·BT(B)
water meter26+60.97·RCW  W  14.98
water meter26+62.48·W  RCW  14.98
water meter26+62.58·W  RCW  14.98
fire hydrant26+63.08·12.88
drainage manhole26+75.61·S  CAS(B)
water meter26+82.85·BT(B)
water meter26+86.17·BT(B)
water meter27+00.74·G  BT(B)  BT(D)
single support sign27+09.55·BT(B)  S
iron rod27+21.57·nothing within reach
water meter27+39.48·BT(B)  G
shared utility pole27+72.63·nothing within reach
shared utility pole27+75.80·RCW
shared utility pole27+78.92·27+00
iron pipe27+85.16·nothing within reach
water valve cover27+87.25·W
telephone pedestal27+97.01·27+00
drainage manhole27+97.26·BT(B)  RCW  S
water valve cover27+99.38·BT(B)  RCW
water valve cover28+08.68·nothing within reach
reclaimed water valve cover28+14.52·RCW  BT(B)  2' Curb And Gutter
reclaimed water valve cover28+23.93·RCW  BT(B)  2' Curb And Gutter
shared utility pole28+48.42·BT(B)  +13.18
shared utility pole28+51.24·+13.18  2' Curb And Gutter
water valve cover28+51.24·W  S  28+00
water meter28+57.48·G  13.88  3.38
sanitary manhole28+57.03·S  28+00  W
water meter28+58.08·G  12.67  2' Curb And Gutter
reclaimed water valve cover28+58.44·W  9.68  9.99
reclaimed water valve cover28+58.59·W  9.68  9.99
shared utility pole28+58.44·BT(B)
water meter28+59.19·W  RCW
water valve cover28+61.40·W  9.68  9.99
single support sign28+60.95·13.99  6.99  14.63
drainage manhole28+67.17·BT(B)  BT(8)  G
drainage manhole28+67.48·S  12.03  BT(8)
iron pipe28+78.39·14.20  14.33
iron pipe28+80.40·13.74  W
iron pipe28+81.71·W
drainage manhole28+82.37D-21D-21  12.76  13.22
water meter28+83.62·W  RCW  14.33
water valve cover28+82.27·9.00
water meter28+83.77·W  RCW  14.33
water valve cover28+82.47·9.00
water meter28+84.43·RCW  14.33  W
shared utility pole28+84.63·nothing within reach
fire hydrant28+86.59·W  11.50  10.14
shared utility pole28+87.20·10.72  W  10.14
water meter28+88.65·nothing within reach
reclaimed water valve cover28+89.91·+12.38  CAS(B)  D-21
iron pipe28+91.67·CAS(B)  +12.38  D-21
iron pipe28+91.97·W  1.93
iron pipe28+92.23·CAS(B)  BT(B)  +12.38
water valve cover28+93.23·11.74  11.50  11.03
iron pipe29+27.89·BT(B)  RCW
iron pipe29+62.45·10.52  10.65
iron pipe29+64.12·10.53

950 lines read from this sheet, including rotated title block lettering. The 400 longest are listed here. Hover a row to zoom to it on the sheet.

TextConfidenceType
5. FINISHED ASPHALT SURFACE SHALL MEET CROSS SLOPE INDICATED AND0.998Note or long string
7. ENSURE POSITIVE DRAINAGE IS PRESERVED OR IMPROVED ACROSS THE0.978Note or long string
5.1. CONTRACTOR SHALL REVIEW ROADWAY LONGITUDINAL GRADES PRIOR0.999Note or long string
3. ROAD BASE AND ASPHALT WEARING COURSES SHALL BE CONSTRUCTED0.997Note or long string
ASPHALT PAVEMENT SHALL BE MILLED SUFFICIENTLY DEEP TO PROVIDE0.988Note or long string
2. PROVIDE BEDDING AND PIPE BACKFILL WITHIN THE PIPE ZONE AS0.988Note or long string
IN ACCORDANCE WITH C.O.T. TRANSPORTATION TECHNICAL STANDARDS1.0Note or long string
FOR ASPHALT OVERLAY TO THE LEVEL AND CROSS SLOPES INDICATED.0.993Note or long string
SHALL MATCH GUTTER LINE FOR EXISTING CURB/GUTTER STREETS OR1.0Invert or rim value
GREATER THAN 1/4" DEEP SHALL REMAIN AT A TIME 2 HOURS AFTER0.981Note or long string
6. MILLING AND RESURFACING OPERATIONS SHALL BE PERFORMED IN0.991Note or long string
REQUIRED TO ALLOW ALL DRIVEWAY APRONS TO ADEQUATELY DRAIN.0.994Note or long string
ACCORDANCE WITH FDOT STANDARD SPECIFICATIONS, SECTION 327-0.991Note or long string
4. FOR ROADWAY AREA OUTSIDE OF THE TRENCH ZONE, EXISTING0.991Note or long string
SHALL PROVIDE A 6" CURB REVEAL FOR BARRIER CURB STREETS.0.991Note or long string
OTHERWISE BY THE CONTRACTOR APPLIED AT A SUFFICIENT RATE0.991Note or long string
FOR NON-CURBED STREETS, MILLING SHALL EXTEND TO A DEPTH0.986Note or long string
TO PAVEMENT RESTORATION WORK TO ENSURE THAT NO PONDING0.993Note or long string
5. FINISHED ASPHALT SURFACE SHALL MEET CROSS SLOI0.993Note or long string
THE SURFACE HAS BEEN FLOODED BY A STORM EVENT OR0.99Note or long string
1. OPEN CUT TRENCH FOR UTILITY INSTALLATION.0.972Note or long string
FOR NON—CURBED STREETS,MILLING SHALL EXTEND0.945Note or long string
MILLING OF EXISTING ASPHALT PAVEMENT.0.994Note or long string
TO SATISFY ENGINEER OR HIS DESIGNEE.0.993Note or long string
PAVEMENT RESTORATION PLAN AND DETAIL0.998Note or long string
ENTIRE MILLED AND RESURFACED AREA.0.989Note or long string
PROFILE MILL EXISTING ASPHALT AS0.996Note or long string
PROP. TYPE BR-1 STORMWATER INLET0.989Proposed work callout
ASPHALT MATERIAL/THICKNESS (IN.)0.999Note or long string
PROP. TYPE BR-1 STORMWATER INLET0.996Proposed work callout
PROP. TYPE BR-1 STORMWATERINLET0.978Proposed work callout
Stormwater Engineering Division0.999Note or long string
CROSS SLOPES AS SHOWN ON PLANS0.998Note or long string
PROP. AREA TO BE RE- SURFACED0.999Proposed work callout
BASE MATERIAL/THICKNESS (IN.)1.0Note or long string
PROP. AREA TO BE RE-SURFACED1.0Proposed work callout
RESTORATION = PIPE ZONE + 5'0.982Note or long string
TRENCH BACKFILL COMPACTED TO0.993Note or long string
98% MODIFIED PROCTOR (AASHTO0.985Note or long string
PROP. AREA TO BE RE-SURFACED0.999Proposed work callout
PAVEMENT RESTORATION NOTES:0.993Note or long string
(STA. 21+83 TO STA. 24+93)0.999Note or long string
(STA. 21+00 TO STA. 27+45)0.996Note or long string
REQUIRED TO MEET GRADE AND0.997Note or long string
COLLECTOR / ARTERIAL. (II)0.978Note or long string
EXISTING PAVEMENT SECTION0.997Existing condition callout
MILLING & OVERLAY LIMITS0.998Other lettering
MILLING & OVERLAY LIMITS0.995Other lettering
UNDISTURBED OR COMPACTED0.999Other lettering
PROP. STORMWATER PIPING0.998Proposed work callout
PROP. STORMWATER PIPING0.994Proposed work callout
LIMITS OF RE-PROFILING1.0Other lettering
SEE DETAIL, THIS SHEET0.999Other lettering
SEE DETAIL, THIS SHEET1.0Other lettering
SHADED AREA REPRESENTS1.0Other lettering
AREA TO BE RE-SURFACED1.0Other lettering
T-180), 12" MAX. LIFTS0.967Other lettering
T-180), 12” MAX. LIFTS0.964Other lettering
CAS(D) - - - - - CAS(D0.829Other lettering
PAVEMENT REQUIREMENTS:1.0Other lettering
ASPHALT MATERIAL/THICI1.0Other lettering
STREET CLASSIFICATION1.0Other lettering
DRAINAGE IMPROVEMENTS1.0Other lettering
OTHERWISE REQUIRED.0.995Other lettering
SEE DETAIL, SHEET X0.995Other lettering
CRUSHED CONC. / 12"0.998Other lettering
Mobility Department1.0Other lettering
BT(D) 24 +0024+000.879Other lettering
BF(B)=二二== BF(B)=二0.667Other lettering
2' Curb And Gutter0.976Invert or rim value
2' Curb And Gutter0.963Invert or rim value
NATIVE SOILS (TYP)0.998Other lettering
SEE TRAFFIC PLANS1.0Other lettering
OVERLAY (SP-12.5)0.976Other lettering
BT()" CōnC. Curb0.855Other lettering
INSET(SEE BELOW)1.0Other lettering
1.5" ASPHALT AND0.97Other lettering
SCALE: 1" = 30'0.952Other lettering
SCALE: 1” = 30'0.938Other lettering
SCALE: 1" = 20'0.952Other lettering
SCALE: 1” = 20'0.957Other lettering
TRENCH PAVEMENT0.999Other lettering
ASPHALT WEARING0.999Other lettering
(WHERE PRESENT)0.982Other lettering
PIPE ZONE WIDTH0.996Other lettering
WOODMERE & LOIS0.999Other lettering
Conc. Sidewalk0.998Other lettering
-4" Conc. Curb0.93Other lettering
— PROP. STORMW0.982Other lettering
Conc. Sidewalk0.975Other lettering
Conc. Sidewalk0.999Other lettering
Conc. Sidewalk1.0Other lettering
Conc. Sidewalk1.0Other lettering
-4” Conc. Curb0.986Other lettering
Conc. Sidewalk1.0Other lettering
-4" Conc. Curb0.959Other lettering
DATE: 05/21/250.986Other lettering
4' Conc. S/W-0.973Other lettering
4" Conc. Curb0.99Other lettering
4" Conc. Curb0.965Other lettering
4” Conc. Curb0.961Other lettering
=SRB2(B)OT(B)0.787Other lettering
CAS(B)-CAS(B)0.942Other lettering
() Conc. Curb0.877Other lettering
4” Conc. Curb0.959Other lettering
-6' PVC Fence0.97Pipe or utility spec
4" Conc. Curb0.945Other lettering
EXISTING CURB0.999Existing condition callout
AND/OR GUTTER1.0Invert or rim value
CAS(B) CAS(B)0.944Other lettering
RCWS(BCASA(B)0.812Other lettering
CITY of TAMPA0.971Other lettering
WOODMERE RD.1.0Other lettering
4' Conc. S/W0.971Other lettering
NESTORY RAEL0.593Other lettering
CASAS(B) (B)0.567Other lettering
ATLAS I - 90.912Other lettering
BT(B)CAS(B)0.993Other lettering
RESIDENTIAL1.0Other lettering
RESIDENTIAL1.0Other lettering
Éonc Siwalk0.745Other lettering
(SEE TABLE)1.0Other lettering
BASE COURSE0.998Other lettering
(SEE TABLE)1.0Other lettering
(B) BT(B)0.547Other lettering
CASTEGAS(B)0.751Other lettering
CAR(BSAS(B)0.846Other lettering
ott a 0250.638Other lettering
ATLAS 1- 90.955Other lettering
Conc. Curb0.999Other lettering
CONÇ. WALK0.919Other lettering
BRICK WALK1.0Other lettering
=SRBAOT(B)0.742Other lettering
Conc. Curb0.999Other lettering
Bonc. Curb0.981Other lettering
Conc. Curb0.997Other lettering
Conc. Curb0.998Other lettering
CAS(BAS(B)0.952Other lettering
= = BT(B)0.796Other lettering
CAS(B) — —0.951Other lettering
ASPHAT TTY0.628Other lettering
SHADED ARI0.946Other lettering
ATLAS I- 90.957Other lettering
RCWXBCAASB0.661Other lettering
SW2023-141.0Other lettering
BFOT(B) —0.901Pipe or utility spec
nc. Curb-0.969Other lettering
Conc. D/w0.91Other lettering
CON. WALK0.988Other lettering
Conc. D/W0.999Other lettering
Conc. D/W0.999Other lettering
Conc. D/W0.977Other lettering
Conc. S/W0.999Other lettering
BT(B) — —0.82Other lettering
25+00(B))0.958Other lettering
-6" Water0.915Other lettering
-4" Conc.0.931Other lettering
Conc. D/W0.999Other lettering
CASLBAS(A0.701Other lettering
AS(BAS(D)0.941Other lettering
BCABS)(B)0.863Other lettering
CAS(B) = 0.888Other lettering
- - BT(B)0.788Other lettering
1-4~ COND0.884Other lettering
onc. D/Ww0.787Other lettering
- - BT(B)0.863Other lettering
Conc. D/w0.864Other lettering
ONE STORY1.0Other lettering
ONE STORY1.0Other lettering
Brick D/W0.999Other lettering
Conc. D/W0.994Other lettering
HHAHHHHHE0.7Other lettering
Conc. D/W0.989Other lettering
Conc. D/W0.999Other lettering
Brick D/W0.98Other lettering
PLAN VIEW1.0Other lettering
ATLAS 1-90.996Other lettering
94.88'(P)1.0Other lettering
PIPE ZONE0.843Other lettering
PIPE O.D.0.999Other lettering
EX. 14.870.975Existing condition callout
EX. 14.870.979Existing condition callout
EX. 15.000.987Existing condition callout
PLAN VIEW0.999Other lettering
REVISIONS1.0Other lettering
REVISIONS1.0Other lettering
Conc D/w0.866Other lettering
LIMITS C0.972Other lettering
Sidewalk0.88Other lettering
Conc D/W0.78Other lettering
== BT(D)0.71Other lettering
VAULIFOQ0.866Other lettering
4" Conc.0.941Other lettering
111.76460.953Other lettering
CAS(B) —0.95Other lettering
WASEASCD0.773Other lettering
CAS(B) —0.979Other lettering
E/G1B(B)0.563Other lettering
-13.40 00.712Other lettering
-- BT(B)0.874Other lettering
1-4”COND0.953Other lettering
DRIVEWAY1.0Other lettering
DRIVEWAY1.0Other lettering
SIDETIAL0.863Other lettering
882020050.574Other lettering
2% SLOPE0.938Other lettering
2% SLOPE0.999Other lettering
18" MIN.0.935Other lettering
18” MIN.0.917Other lettering
18" MIN.0.931Other lettering
18” MIN.0.932Other lettering
EXISTING1.0Existing condition callout
EXISTING1.0Existing condition callout
EXISTING1.0Existing condition callout
CAS(B) —0.963Other lettering
-RCAS(D)0.727Other lettering
CAS(D) —0.942Other lettering
78.6'(R)0.998Other lettering
ot D11200.693Other lettering
EX.14.871.0Existing condition callout
EX.14.871.0Existing condition callout
EX.15.001.0Existing condition callout
BFOT(B)0.863Pipe or utility spec
-8FOT()0.856Other lettering
(8)18 —0.509Other lettering
A一BT(D)0.791Other lettering
BT(B) -0.908Other lettering
= BT(D)0.908Other lettering
- BT(D)0.948Other lettering
CAS(B)-0.897Other lettering
CASYBCW0.903Other lettering
RCAW(B)0.982Other lettering
BCAS(B)0.766Other lettering
BTA8(B)0.649Other lettering
BA(B(B)0.845Other lettering
RCWB(B)0.778Other lettering
ASPHALT1.0Other lettering
3.0' Dp0.967Other lettering
ASPHALT1.0Other lettering
PULLBOX1.0Other lettering
3.0' Dp0.946Other lettering
3.0' Dp0.973Other lettering
1.0' Dp0.903Other lettering
− BT(B)0.885Other lettering
3.0' Dp0.945Other lettering
3.0' Dp0.951Other lettering
DRIVEWA1.0Other lettering
60° R/W0.949Other lettering
- BT(B)0.854Other lettering
SURFACE1.0Other lettering
- BT(B)0.88Other lettering
BT(B) -0.895Other lettering
BT(B) =0.991Other lettering
DDIFILL0.747Other lettering
EDDIILL0.763Other lettering
CAS(B)=0.945Other lettering
= BT(B)0.931Other lettering
3.0' Dp0.969Other lettering
60' R/W0.863Other lettering
FOT(8)0.905Other lettering
- RCW-0.858Other lettering
W.·ALE0.833Other lettering
E.O.P.0.939Other lettering
VAULTG0.999Other lettering
4' MEF0.915Other lettering
BFT(B)0.627Other lettering
2' SRF0.96Other lettering
E.O.P.0.834Other lettering
Sidwak0.824Other lettering
- RCW-0.868Other lettering
AZEELE0.884Other lettering
- RCW-0.962Other lettering
2' SRF0.967Other lettering
5' WBF0.945Other lettering
2' SRF0.908Other lettering
2' SRF0.946Other lettering
BT(B)+0.987Other lettering
-BT(D)0.899Other lettering
VAULT-0.969Other lettering
E.O.P.0.925Other lettering
BT(B))0.673Other lettering
CAS(D)1.0Utility witness tag
CAS(B)1.0Utility witness tag
CAS(B)1.0Utility witness tag
CAS(D)1.0Utility witness tag
CRS(DN0.784Other lettering
CAS(B)0.997Utility witness tag
CAS(B)1.0Utility witness tag
CAS(B)1.0Utility witness tag
−BT(B)0.947Other lettering
CAS(B)1.0Utility witness tag
600 BT0.995Other lettering
CAS(B)1.0Utility witness tag
CAS(B)1.0Utility witness tag
BT()110.742Other lettering
+12.380.996Spot elevation
3.0 Dp0.996Other lettering
3.0 Dp0.932Other lettering
3.0 Dp0.908Other lettering
1.0 000.742Other lettering
+11.780.998Spot elevation
+13.181.0Spot elevation
RCWRCW0.913Other lettering
.·ATIO0.841Other lettering
60'R/W0.915Other lettering
60’R/W0.916Other lettering
+15.670.94Spot elevation
*15.670.911Other lettering
60'R/W0.96Other lettering
E.O.P.0.947Other lettering
E.0.P.0.799Other lettering
E.O.P.0.816Other lettering
--BTB)0.739Other lettering
E.O.P.1.0Other lettering
CAS(B)1.0Utility witness tag
CAS(时)0.748Utility witness tag
CAS(B)0.984Utility witness tag
BT(B))0.707Other lettering
BT(B))0.882Other lettering
CAS(B)1.0Utility witness tag
CAS(B)1.0Utility witness tag
CAS(B)1.0Utility witness tag
CAS(D)1.0Utility witness tag
CAS(B)0.965Utility witness tag
CAS(D)1.0Utility witness tag
CAS(B)1.0Utility witness tag
- RCW-0.888Other lettering
60’R/W0.915Other lettering
S.E.B.1.0Other lettering
-RCW-0.893Other lettering
-RCW-0.86Other lettering
BT(B)1.0Utility witness tag
Conc.1.0Other lettering
_.ALE0.72Other lettering
Conc.1.0Other lettering
4'MEE0.916Other lettering
BT()0.886Other lettering
SOUTH1.0Other lettering
9.38S0.963Other lettering
2 SRF0.967Other lettering
10.240.993Spot elevation
-RCW-0.952Other lettering
10.040.986Spot elevation
VAULT1.0Other lettering
2 SRF0.895Other lettering
10.720.892Spot elevation
10.020.756Spot elevation
10.160.971Spot elevation
10.410.979Spot elevation
2 SRF0.885Other lettering
21+001.0Station
22+000.935Station
10.600.968Spot elevation
10.140.686Spot elevation
BT(D)0.91Utility witness tag
BT(D)0.562Utility witness tag
BT(D)1.0Utility witness tag
BT(D)1.0Utility witness tag
BT(D)1.0Utility witness tag
BTBBT0.791Other lettering
BT(B)0.998Utility witness tag
BT(D)1.0Utility witness tag
28+001.0Station
26+001.0Station
BT(D)1.0Utility witness tag
BT(B)0.993Utility witness tag
BT(D)1.0Utility witness tag
BT(D)1.0Utility witness tag
29+001.0Station
27+000.998Station
E.O.P0.989Other lettering
11.500.783Spot elevation
11.740.987Spot elevation
11.030.853Spot elevation
10.531.0Spot elevation
13.970.868Spot elevation
13.650.997Spot elevation
13.540.992Spot elevation
BT(B)1.0Utility witness tag
Conc.1.0Other lettering
BT(B)0.969Utility witness tag
12.880.805Spot elevation
-RCW-0.872Other lettering
12.980.801Spot elevation
87(8)0.88Other lettering
BT(B)0.887Utility witness tag
10.650.978Spot elevation
BT(B)0.846Utility witness tag
10.520.825Spot elevation
BT(B)1.0Utility witness tag
AS(B)0.997Other lettering
BT(B)1.0Utility witness tag
BT(B)1.0Utility witness tag
CASCW0.803Other lettering
BT(B)0.979Utility witness tag
BT(B)0.998Utility witness tag
AS(D)1.0Other lettering
BT(B)0.984Utility witness tag
ST(0)0.783Other lettering
BT(B)1.0Utility witness tag

The sheet as continuous text, in the order a person would read it. Note columns become prose, printed tables stay tables.

SW2023-14

PLAN VIEW

PLAN VIEW

No.DATEREVISIONS
3
2
1
No.DATEREVISIONS
6
5
4

DES: S.E.B.

DRN: BB

CKD: JDM

DATE: 05/21/25

CITY of TAMPA

Mobility Department

Stormwater Engineering Division

WOODMERE & LOIS DRAINAGE IMPROVEMENTS PAVEMENT RESTORATION PLAN AND DETAIL

SHEET 8

OF 9

Every printed table on this sheet, recovered as rows and cells.

Revision block

No. | DATE | REVISIONS | No. | DATE | REVISIONS | DE | DR | CK 3 | | | 6 | | | | | 2 | | | 5 | | | | |

Sheet
9 of 9 detail
Text lines
323 each located on the sheet
Symbols
0 0 classes
Viewports
9 titled drawings found

TREE PROTECTION & SILT FENCE SHEET

This is a detail-and-notes sheet (Sheet 9 of 9) that instructs the contractor on how to protect existing trees during construction and how to install silt fencing and inlet protection for stormwater erosion control. It defines the Protective Root Zone (PRZ) offsets for palms, protected, specimen, and grand trees, and shows the required tree protection fence, warning signs, and mulch layers. It also details Type IV silt fence construction (posts, fabric, rock bags), silt fence protection around ditch inlets, and the required protection of stormwater inlets (partial and completed inlets) with rock bags or approved equal.

Viewports

TitleKindScaleContents
Upper-left tree graphic with notes (treated as 'GRAND TREES' / tree protection detail)detail (elevation/plan of single tree with fence and PRZ dimension lines)none printed per viewport (sheet scale 1/4" = 1'-0")Lined tree in cross-section/plan with protective fence hatch, PRZ boundary line, dimension callouts '10' min (tree <24" DBH) measured from edge of trunk' and '15' min (tree <24" DBH) measured from edge of trunk', PRZ labels. Left NOTES block (items 1-5: see specs for additional tree protection requirements; no existing irrigation see watering requirements; pruning per ANSI A300; no equipment inside protective fencing during install/removal; see site prep plan for modifications). Right text: 'Tree Protection fence: High Density Polyethylene Fencing with 3.5" x 1.5" openings; color orange; attach to steel or wood posts installed at 6' or on center.', '2" x 4' to 6' steel posts or approved equal.', '3" thick layer of mulch (eucalyptus or City approved equivalent); no closer than 1' from trunk.', 'Maintain existing natural grade with the tree protection fence unless otherwise indicated on the plans', 'Root pruning shall be performed to ANSI A300 standards; must be clean, severed cuts (not jagged, frayed, etc.) performed with a hand-saw or Dosko Root Pruner or approved equivalent equipment.'
TREE PROTECTION FOR GRAND TREEdetail (plan/elevation of grand tree with fence and PRZ)none printed per viewport (sheet scale 1/4" = 1'-0")Grand tree with crown spread/drip line limit of Tree Protection, fence hatch, '20' minimum measured from edge of trunk' dimension, PRZ labels. Annotations: '8.5' x 11" cardboard warning with 2" hgt. black lettering; Sign to be laminated in a waterproof, and fastened to fence with plastic zipties or equivalent to prevent sagging; Locate one (1) sign every 50' on calford fence.' (as printed), 'Tree Protection fence: 6-8' hgt. Chain Link fence sections in Metal Frame sections; mount with Stanchions or Steel posts on Movable Core Drill Concrete Blocks, installed at 8' on center.', '2" x 4' to 6' steel posts or approved equal.', '3" thick layer of mulch (eucalyptus or City approved equivalent); no closer than 1' from trunk.', plus grade/root-pruning notes as in left graphic.
Silt fence elevation/section detail (upper right)detail (elevation + section + inlet-protection plan callouts)none printedPOST OPTIONS (SOFTWOOD 2 1/2" DIA, SOFTWOOD 2 1/4", HARDWOOD 1 3/4" x 1 1/2" DIA, STEEL 1.33 LBS./FT. MIN); ELEVATION labeled TYPE IV SILT FENCE with 6' MAX, 2'-0" MIN, 1'-0" MIN, 2'-0" MAX, FILTER FABRIC (IN CONFORMANCE WITH SEC. 985 TDOT SPEC.); SECTION showing PRINCIPLE POST POSITION (CANTED 20° TOWARD FLOW), FILTER FABRIC, SILT FLOW; small plan details 'SILT FENCE PROTECTION AROUND DITCH BOTTOM INLETS' (SILT FENCE around STORMWATER INLET) and 'SILT FENCE PROTECTION IN DITCHES WITH INTERMITTENT FLOW' (WITH WEEP/HOUSING).
NOTES FOR SILT FENCEStable/legend block (numbered notes)noneNote 1: TYPE IV SILT FENCE TO BE USED AT MOST LOCATIONS; TYPE IV SILT FENCE TO BE USED WHERE HEAVY SEDIMENT LOADS ARE ANTICIPATED, SUGGESTED USE IS WHERE FILL SLOPE IS 1:2 OR STEEPER AND LENGTH OF SLOPE EXCEEDS 25 FEET, AVOID WHERE THE DRAINING WATER MAY BACK INTO TRAVEL LANES OR OFF THE RIGHT OF WAY. Note 2: DO NOT CONSTRUCT SILT FENCES ACROSS PERMANENT FLOWING WATERCOURSES; SILT FENCES ARE TO BE UPLAND LOCATIONS AND TURBIDITY BARRIERS USED AT PERMANENT BODIES OF WATER. Note 3: WHERE USED AS SLOPE PROTECTION, SILT FENCE IS TO BE CONSTRUCTED ON OR LONGITUDINAL GRADE TO AVOID CHANNELIZING RUNOFF ALONG THE LENGTH OF THE FENCE.
SILT FENCE DETAIL — NOT TO SCALE (partial/completed inlet)detail (two inlet plans: PARTIAL INLET and COMPLETED INLET)not to scalePARTIAL INLET plan showing PROPOSED INLET, TEMP. DRAIN, ROCK BAGS, CURB & GUTTER; COMPLETED INLET plan showing SIDEWALK, CURB & GUTTER, ROCK BAGS.
INLET PROTECTION DETAIL — NOT TO SCALE (numbered callouts 1-6)detail (callout/legend list)not to scaleNumbered list: (1) 3-inch layer of mulch (eucalyptus or city approved equivalent); no mulch shall be placed within one foot of the trunk. (2) Grand Tree Protection Fence: 6-foot or 8-foot high chain link in metal frame sections; mount with stanchions or steel posts on movable core drilled concrete blocks, installed on 8' on center max spacing. (3) Notice Sign: 8.5" x 11" corrugated plastic warning with 2" high black lettering; Fasten to fence with plastic zip toes or similar. Locate one sign every 50' of along the fence. (4) Maintain existing natural grade within the tree protection fence unless noted otherwise on the plans. (5) Standard Tree Protection Fence: high density polyethylene fencing with 3.5-inch x 1.5-inch openings; color orange; attach to steel or wood posts installed at eight-foot on center max. (6) 2x2x6' posts embedded a minimum of 24-inches (or similar approved post). Plus 'NOTE: INSTALL FDOT INLET PROTECTION OR APPROVED EQUAL'.
GRAND TREES (lower left, numbered detail 1-6)detail (plan/elevation of fenced grand tree with callouts)none printed per viewport (sheet scale 1/4" = 1'-0")Fenced tree with hatched fence, callout bubbles 1-6 (1 fence, 2 posts, 3 sign, 4 grade, 5 mulch, 6 post embedment), '6' min' fence height dimension, PRZ labels, TREE PROTECTION AREA DO NOT DISTURB THIS AREA sign graphic.
PALMS, PROTECTED AND SPECIMEN TREES (lower center, numbered detail)detail (plan/elevation of fenced tree with callouts)none printed per viewport (sheet scale 1/4" = 1'-0")Fenced tree with hatched/dashed fence, callout bubbles 1, 4, 5, 6, '4' min' dimension, PRZ labels, root zone hatching below grade.
TREE PROTECTION NOTES (lower right text block)table/legend block (numbered notes + PRZ definition + fence-extent bullets)noneNotes 1-7 (minimum protection standards met before construction; no changes to predevelopment PRZ; protective barricades may be removed only for non-mechanical landscaping within PRZ, no alteration to any part of tree not approved by Natural Resources Coordinator/designee; no parking/storing vehicles/equipment/materials within minimum protective area; no site clearing/grading within minimum protective area except approved; canopy pruning must meet ANSI A300 by ISA Certified Arborist; root pruning per ANSI A300 clean severed cuts with mechanical root pruning tools, no pruning to prune or crush roots). 'PRZ: Protective Root Zone: The entire surface and subsurface soil area encompassed by prescribed radius for protected, specimen, and grand trees.' 'See plan for fence extents, but typically the extents are as follows: Palms: 3' offset FFT; Protected Trees (5- to 23-inch DBH): 10' offset from face of trunk (FFT); Specimen Trees: (24- to 31-inch DBH): 15' offset FFT; Grand Trees (32-inch DBH): 20' offset FFT.'

Quantities this sheet can support

count of protected trees by category (grand / protected / specimen / palms) to be fencedlinear feet of tree protection fence (chain link metal-frame for grand trees; high-density polyethylene/orange fencing for standard trees)count of fence posts / stanchions (2x4' to 6' steel posts or 2x2x6' posts at 6' or 8' on center; concrete block bases)count of tree protection warning signs (one per 50' of fence; 8.5" x 11" laminated plastic)linear feet / square feet of 3" mulch layer (eucalyptus or approved) within fence, kept 1' from trunklinear feet of Type IV silt fence (and length of softwood/hardwood/steel posts)count of stormwater inlets requiring silt-fence/inlet protection (partial and completed inlets) and count of rock bags for inlet protection

Key notes read from the sheet

  • PRZ = Protective Root Zone: 'The entire surface and subsurface soil area encompassed by prescribed radius for protected, specimen, and grand trees.'
  • Typical fence extents by tree class: 'Palms: 3' offset FFT; Protected Trees (5- to 23-inch DBH): 10' offset from face of trunk (FFT); Specimen Trees: (24- to 31-inch DBH): 15' offset FFT; Grand Trees (32-inch DBH): 20' offset FFT.'
  • Grand Tree Protection Fence: '6-foot or 8-foot high chain link in metal frame sections; mount with stanchions or steel posts on movable core drilled concrete blocks, installed on 8' on center max spacing.'
  • Standard Tree Protection Fence: 'high density polyethylene fencing with 3.5-inch x 1.5-inch openings; color orange; attach to steel or wood posts installed at eight-foot on center max.'
  • Notice Sign: '8.5" x 11" corrugated plastic warning with 2" high black lettering; Fasten to fence with plastic zip toes or similar. Locate one sign every 50' of along the fence.'
  • Mulch: '3-inch layer of mulch (eucalyptus or city approved equivalent); no mulch shall be placed within one foot of the trunk.'
  • Posts: '2x2x6' posts embedded a minimum of 24-inches (or similar approved post).'
  • Inlet protection: 'NOTE: INSTALL FDOT INLET PROTECTION OR APPROVED EQUAL.'
  • Silt fence Note 1: 'TYPE IV SILT FENCE TO BE USED AT MOST LOCATIONS; TYPE IV SILT FENCE TO BE USED WHERE HEAVY SEDIMENT LOADS ARE ANTICIPATED, SUGGESTED USE IS WHERE FILL SLOPE IS 1:2 OR STEEPER AND LENGTH OF SLOPE EXCEEDS 25 FEET, AVOID WHERE THE DRAINING WATER MAY BACK INTO TRAVEL LANES OR OFF THE RIGHT OF WAY.'
  • Silt fence Note 2: 'DO NOT CONSTRUCT SILT FENCES ACROSS PERMANENT FLOWING WATERCOURSES; SILT FENCES ARE TO BE UPLAND LOCATIONS AND TURBIDITY BARRIERS USED AT PERMANENT BODIES OF WATER.'
  • Silt fence Note 3: 'WHERE USED AS SLOPE PROTECTION, SILT FENCE IS TO BE CONSTRUCTED ON OR LONGITUDINAL GRADE TO AVOID CHANNELIZING RUNOFF ALONG THE LENGTH OF THE FENCE.'
  • Tree protection Note 2: 'No changes to the predevelopment conditions within the approved protective root zone during the construction process.'
  • Tree protection Note 4: 'No parking or storing of vehicles, equipment, or materials is permitted within the minimum protective area, at any time.'
  • Tree protection Note 6: 'All canopy pruning must Meet ANSI A300 pruning per "American National Standards for Tree Care Operations". ANSI. A300, current edition. Work should be planned and supervised by an ISA Certified Arborist.'
  • Tree protection Note 7: 'Root Pruning shall be performed to ANSI A300 standards; must be clean, severed cuts (not jagged or frayed). Root pruning shall be performed with specifically designed mechanical root pruning tools (Vermeer or Dosko) or hand pruners, loppers, hand saws, reciprocating saws, oscillating saws, or small chain saws. Trenchers, excavators, and backhoes shall not be used to prune or crush roots.'
  • Sheet scale (bottom left of drawing area): '1/4" = 1'-0"'; several detail viewports explicitly marked 'NOT TO SCALE'.

Every line on the sheet is typed by what it is: a structure callout, a station, an invert value, a utility witness tag, a proposed or existing note. That is what makes an annotation addressable rather than merely readable. Hover a row to light every instance of that type on the sheet.

Annotation typeCountExample
Proposed work callout1PROPOSED INLET
Invert or rim value2CURB & GUTTER
Note or long string131TYPE III SILT FENCE TO BE USED AT MOST LOCATIONS. TYPE IV SILT FENCE TO BE USED WHERE LARG
Other lettering189Sign to be laminated in a

Surveyed symbols found on this sheet, named by the set's own legend. Hover a class to light every instance at once. Counts are reported as found, never adjusted to match an expectation.

Legend classCount
None detected on this sheet.

Every instance, with the callouts printed beside it

Each located symbol, and the text on the sheet within reach of it, nearest first. Distances are real feet at the sheet scale, not pixels. Where a callout carries an identifier that names this kind of feature, it is promoted to ID; proximity alone does not establish labelling, agreement does. Hover a row to zoom to that symbol.

SymbolStationIDCallouts within reach
None.

323 lines read from this sheet, including rotated title block lettering. The 400 longest are listed here. Hover a row to zoom to it on the sheet.

TextConfidenceType
TYPE III SILT FENCE TO BE USED AT MOST LOCATIONS. TYPE IV SILT FENCE TO BE USED WHERE LARGE SEDIMENT LOADS0.989Note or long string
ARE ANTICIPATED. SUGGESTED USE IS WHERE FILL SLOPE IS 1: 2 OR STEEPER AND LENGTH OF SLOPE EXCEEDS 25 FEET.0.989Note or long string
WHERE USED AS SLOPE PROTECTION, SILT FENCE IS TO BE CONSTRUCTED ON O% LONGITUDINAL GRADE TO AVOID0.987Note or long string
DO NOT CONSTRUCT SILT FENCES ACROSS PERMANENT FLOWING WATERCOURSES. SILT FENCES ARE TO BE UPLAND0.999Note or long string
AVOID WHERE THE DETAINED WA TER MAY BACK INTO TRAVEL LANES OR OFF THE RIGHT OF WAY.0.983Note or long string
alteration(s), of any kind, shall be made to any part of the tree (roots, trunk,0.997Note or long string
public or private right-of-way, in accordance with the tree protection graphics0.994Note or long string
No parking or storing of vehicles, equipment, or materials is permitted within0.996Note or long string
No site clearing or grading is permitted within the minimum protective area,0.992Note or long string
Minimum protection standards shall be met for all protected trees, prior to0.998Note or long string
commencement of any construction activities on a development site and/or in1.0Note or long string
No changes to the predevelopment conditions within the approved protective0.999Note or long string
for final landscaping activities. During this activity only non-mechanical0.99Note or long string
canopy/crown), other than those that are approved by the Natural Resources0.993Note or long string
hand pruners, loppers, hand saws, reciprocating saws, oscillating saws, or0.997Note or long string
small chain saws. Trenchers, excavators, and backhoes shall not be used to0.997Note or long string
Protective barricades may be removed only to prepare the development site1.0Note or long string
severed cuts (not jagged or frayed). Root pruning shall be performed with0.994Note or long string
specifically designed mechanical root pruning tools (Vermeer or Dosko) or1.0Note or long string
Standards for Tree Care Operations". ANSI. A300, current edition. Work0.998Note or long string
Root Pruning shall be performed to ANSI A300 standards; must be clean,0.994Note or long string
All canopy pruning must Meet ANSI A300 pruning per "American National0.993Note or long string
LOCATIONS AND TURBIDITY BARRIERS USED AT PERMANENT BODIES OF WA TER.0.994Note or long string
Crown spread/drip line or other limits of Tree Protection area. See0.994Note or long string
techniques may occur within the designated protective root zone. No1.0Note or long string
other than those changes that are approved by the Natural Resources1.0Note or long string
AVOID WHERE THE DETAINED WATER MAY BACK INTO TRAVEL LANES OR OFF0.987Note or long string
WHERE USED AS SLOPE PROTECTION, SILT FENCE IS TO BE CONSTRUCTEL0.995Note or long string
should be planned and supervised by an ISA Certified Arborist.0.996Note or long string
See plan for fence extents, but typically the extents are as0.987Note or long string
high black lettering. Fasten to fence with plastic zip toes1.0Note or long string
Maintain existing natural grade within the tree protection1.0Note or long string
Notice Sign: 8.5" x11" corrugated plastic warning with 2"0.987Note or long string
or similar. Locate one sign every 50' of along the fence.0.994Note or long string
Crown spread/drip line or other limit of Tree Protection0.994Note or long string
equivalent); no mulch shall be placed within one foot of1.0Note or long string
Grand Tree Protection Fence: 6-foot or 8-foot high chain0.994Note or long string
color orange; attach to steel or wood posts installed at1.0Note or long string
olan for fence extents, but typically the extents are as0.999Note or long string
polyethylene fencing with 3.5-inch x 1.5-inch openings;0.998Note or long string
Coordinator or designee, as part of the related permit.0.997Note or long string
Coordinator or designee, as part of the related permit.0.996Note or long string
The entire surface and subsurface soil area encompassed0.994Note or long string
by prescribed radius for protected, specimen, and grand0.999Note or long string
link in metal frame sections; mount with stanchions or0.99Note or long string
area. See Tree preservation plan for fence alignment.1.0Note or long string
stell posts on movable core drilled concrete blocks,1.0Note or long string
Protected Trees (5- to 23-inch DBH): 10' offset from1.0Note or long string
Specimen Trees: (24- to 31-inch DBH):15' offset FFT0.989Note or long string
CHANNELIZING RUNOFF ALONG THE LENGTH OF THE FENCE.0.998Note or long string
3-inch layer of mulch (eucalyptus or city approved0.991Note or long string
2x2x6' posts embedded a minimum of 24-inches (or0.999Note or long string
INSTALL FDOT INLET PROTECTION OR APPROVED EQUAL0.994Note or long string
alteration(s), of any kind, shall be made to ar0.986Note or long string
No site clearing or grading is permitted withir1.0Note or long string
Standard Tree Protection Fence: high density0.999Note or long string
VSTRUCTED ON O% LONGITUDINAL GRADE TO AVOID0.99Note or long string
2- If there is no existing irrigation, see0.988Note or long string
3- Pruning shall be performed to ANSI A3000.998Note or long string
root zone during the construction process.1.0Note or long string
fence unless noted otherwise on the plans.1.0Note or long string
1- See specifications for additional tree0.99Note or long string
specifications for watering reguirements.0.991Note or long string
specifications for watering requirements.1.0Note or long string
protective fencing including during fence0.997Note or long string
le to any part of the tree (roots, trunk,0.992Note or long string
the minimum protective area, at any time.0.998Note or long string
Koot F Tuning snair be penomed to ANSr A30.835Note or long string
Grand Trees (32-inch DBH): 20' offset FFT0.999Note or long string
4- No equipment shall operate inside the0.986Note or long string
steel or wood posts installed at 6'-8'0.999Note or long string
modifications with the Tree Protection1.0Note or long string
installed on 8' on center max spacing.0.999Note or long string
TAMPA TREE PROTECTION DETAIL AND NOTES1.0Note or long string
eservation [plan for fence alignment.0.991Note or long string
Polyethylene Fencing with 3.5" X 1.5"0.996Note or long string
2" X 4' to 6' steel posts or approved0.989Note or long string
2" x 8" steel post or approved equal.0.998Note or long string
5- See site preparation plan for any0.998Note or long string
Maintain existing natural grade with0.99Note or long string
Maintain existing natural grade with1.0Note or long string
Tree Protection fence: High Density0.998Note or long string
3" thick layer of mulch (eucalyptus0.992Note or long string
PALMS, PROTECTED AND SPECIMEN TREES0.989Note or long string
Chain Link fence sections in Matal1.0Note or long string
Blocks, installed at 8' on center.0.999Note or long string
3" thick layer of mulch (eucalytus0.996Note or long string
Root pruning shall be performed to1.0Note or long string
Root pruning shall be performed to1.0Note or long string
VSI A300 standards; must be clean,0.986Note or long string
Nor Aooo Standards, must be cleam,0.894Note or long string
TREE PROTECTION & SILT FENCE SHEET1.0Note or long string
openings; color orange; attach to0.989Note or long string
Tree Protection fence: 6'-8' hgt.0.997Note or long string
or City approved equivalent); no1.0Note or long string
or City approved equivalent); no0.999Note or long string
SILT FENCE PROTECTION IN DITCHES0.991Note or long string
the tree protection fence unless1.0Note or long string
otherwise indicated on the plans1.0Note or long string
clean, severed cuts (not jagged,0.997Note or long string
the tree protection fence unless0.983Note or long string
otherwise indicated on the plans0.991Note or long string
clean, severed cuts (not jagged,0.986Note or long string
INSTALL FDOT INLET PROTECTION OF0.989Note or long string
handsaw or Dosko Root Pruner or1.0Note or long string
handsaw or Dosko Root pruner or1.0Note or long string
Stormwater Engineering Division0.99Note or long string
TREE PROTECTION FOR GRAND TREE1.0Note or long string
equivalnet to prevent sagging.1.0Note or long string
frayed, etc.) performed with a1.0Note or long string
frayed, ect.) performed with a0.993Note or long string
fence with plastic zipties or1.0Note or long string
Locate one (1) sign every 50'0.992Note or long string
approved equivalent equipment1.0Note or long string
approved equivalent equipment0.99Note or long string
HARDWOOD 1 1/2"× 1 1/2" DIA.0.89Note or long string
with 2" hgt. black lettering0.996Note or long string
Stanchions or Steel posts on1.0Note or long string
SILT FENCE PROTECTION AROUND0.983Note or long string
ANSI A300 standards; must be1.0Note or long string
8.5" × 11" cardboad warning0.961Note or long string
8.5" x 11" cardboad warning0.998Note or long string
Movable Core Drill Concrete0.994Note or long string
waterproof, and fastened to1.0Note or long string
ANSI A300 standard; must be1.0Note or long string
measured from edge of trunk1.0Note or long string
measured from edge of trunk0.991Note or long string
measured from edge of trunk1.0Note or long string
measured from edge of trunk0.975Note or long string
Frame sections; mount with1.0Note or long string
closer than 1' from trunk.0.98Note or long string
Sign to be laminated in a1.0Other lettering
installation and removal.1.0Other lettering
closer than 1' from trunk0.992Other lettering
eight-foot on center max.1.0Other lettering
HARDWOOD 1'2"× 1 2" DIA.0.867Other lettering
STEEL 1.33 LBS./FT. MIN.0.998Other lettering
protection requirements.1.0Other lettering
10' min (tree <24" DBH)0.988Other lettering
10' min (free <24" DBH)0.986Other lettering
15' min (tree <24" DBH)0.992Other lettering
15' min (tree <24" DBH)0.988Other lettering
INLET PROTECTION DETAIL1.0Other lettering
plastic material to be1.0Other lettering
NOTES FOR SILT FENCES:0.985Other lettering
WITH INTERMITTENT FLOW0.977Other lettering
similar approved post)1.0Other lettering
WOODMERE & LOIS AVENUE0.999Other lettering
TREE PROTECTION NOTES1.0Other lettering
Protective Root Zone:1.0Other lettering
prune or crush roots.1.0Other lettering
DRAINAGE IMPROVEMENTS1.0Other lettering
SOFTWOOD 2 '/2" DIA.0.923Other lettering
SOFTWOOD 2 1/2" DIA.0.98Other lettering
SEC. 985 FDOT SPEC.)0.989Other lettering
Palms: 3' offset FFT0.973Other lettering
DITCH BOTTOM INLETS0.992Other lettering
nin (tree <24" DBH)0.997Other lettering
face of trunk (FFT)1.0Other lettering
Mobility Department1.0Other lettering
FIL TER FABRIC (IN0.999Other lettering
TYPE IV SILT FENCE1.0Other lettering
IERE & LOIS AVENUE0.997Other lettering
SILT FENCE DETAIL0.982Other lettering
CONFORMANCE WITH0.973Other lettering
on calonf fence.0.973Other lettering
SOFTWOOD 2"x 4"0.975Other lettering
COMPLETED INLET1.0Other lettering
TREE PROTECTION0.998Other lettering
FIL TER FABRIC0.998Other lettering
PROPOSED INLET0.948Proposed work callout
DATE: 05/21/250.999Other lettering
POST OPTIONS:0.999Other lettering
POST POSITION0.995Other lettering
FILTER FABRIC1.0Other lettering
measured fron1.0Other lettering
measured from1.0Other lettering
measured from1.0Other lettering
CURB & GUTTER0.995Invert or rim value
edge of trunk1.0Other lettering
edge of trunk1.0Other lettering
PARTIAL INLET0.999Other lettering
PROTECCION DE1.0Other lettering
CITY of TAMPA0.959Other lettering
TOWARD FLOW)0.996Other lettering
WA TERCOURSE0.973Other lettering
NOT TO SCALE0.985Other lettering
NOT TO SCALE0.971Other lettering
Protective F0.98Other lettering
1/4" = 1'-0"0.991Other lettering
reservation0.974Other lettering
(CANTED 20°1.0Other lettering
WATERCOURSE1.0Other lettering
SIL T FENCE0.935Other lettering
SIL T FENCE0.97Other lettering
20' minimum0.999Other lettering
20' minimum0.998Other lettering
GRAND TREES1.0Other lettering
DRAINAGE II0.993Other lettering
SW 2023-140.987Other lettering
PRIINCIPLE0.985Other lettering
on center.1.0Other lettering
1ANCE WITH0.973Other lettering
standards.1.0Other lettering
SILT FENCE0.999Other lettering
STORMWATER1.0Other lettering
SILT FENCE0.996Other lettering
the trunk.1.0Other lettering
POSITIONS0.994Other lettering
ELEVATION1.0Other lettering
SIL T FEI0.914Other lettering
ROCK BAGS0.997Other lettering
ot 1 250.811Other lettering
REVISIONS1.0Other lettering
REVISIONS1.0Other lettering
OPTIONAL1.0Other lettering
12" MIN.0.666Other lettering
SIDEWALK1.0Other lettering
the trui0.954Other lettering
stell pc0.912Other lettering
KEEP OUT0.997Other lettering
follows:1.0Other lettering
SECTION0.999Other lettering
AREA DE0.999Other lettering
PROTECO0.948Other lettering
ARDOLES0.965Other lettering
o 1 0250.65Other lettering
6'MAX.0.985Other lettering
NOTES:1.0Other lettering
R MORE0.891Other lettering
equal.1.0Other lettering
RUNOFF1.0Other lettering
004/4/0.618Other lettering
CURB &0.991Other lettering
GUTTER1.0Invert or rim value
below.1.0Other lettering
6 min.0.877Other lettering
6' mn.0.829Other lettering
trees.1.0Other lettering
Specir0.999Other lettering
OP T/0.91Other lettering
SIL T0.828Other lettering
TEMP.1.0Other lettering
DRAIN0.999Other lettering
NOTE:0.972Other lettering
FUERA1.0Other lettering
'min.0.828Other lettering
VOTES0.996Other lettering
SHEET1.0Other lettering
POST1.0Other lettering
POS/0.921Other lettering
FLOW1.0Other lettering
memw0.597Other lettering
MMVD0.752Other lettering
FLOW0.912Other lettering
SILT0.991Other lettering
FLON0.95Other lettering
ROCK1.0Other lettering
BAGS1.0Other lettering
AREA1.0Other lettering
PRZ:1.0Other lettering
DATE1.0Other lettering
DATE1.0Other lettering
DES:1.0Other lettering
DRN:1.0Other lettering
CKD:1.0Other lettering
PRZ1.0Other lettering
20±0.999Other lettering
RAL0.929Other lettering
RCA0.715Other lettering
PRZ1.0Other lettering
COI0.974Other lettering
PRZ1.0Other lettering
PRZ1.0Other lettering
vs:0.751Other lettering
Vo.0.943Other lettering
No.1.0Other lettering
No.1.0Other lettering
SEB0.874Other lettering
JDM1.0Other lettering
150.935Other lettering
业业0.953Other lettering
7.0.762Other lettering
1.0.953Other lettering
2.1.0Other lettering
3.0.999Other lettering
1.1.0Other lettering
2.1.0Other lettering
3.1.0Other lettering
4.0.999Other lettering
5.1.0Other lettering
6.1.0Other lettering
Wy0.758Other lettering
7.1.0Other lettering
To0.552Other lettering
B80.512Other lettering
BB1.0Other lettering
OF1.0Other lettering
30.992Other lettering
N0.663Other lettering
小0.863Other lettering
10.999Other lettering
21.0Other lettering
31.0Other lettering
41.0Other lettering
31.0Other lettering
21.0Other lettering
51.0Other lettering
51.0Other lettering
61.0Other lettering
61.0Other lettering
41.0Other lettering
L0.599Other lettering
61.0Other lettering
31.0Other lettering
90.998Other lettering
91.0Other lettering
60.992Other lettering
51.0Other lettering
21.0Other lettering
41.0Other lettering
11.0Other lettering
91.0Other lettering

The sheet as continuous text, in the order a person would read it. Note columns become prose, printed tables stay tables.

SW 2023-14

NOTES FOR SILT FENCES:

  1. TYPE III SILT FENCE TO BE USED AT MOST LOCATIONS. TYPE IV SILT FENCE TO BE USED WHERE LARGE SEDIMENT LOADS ARE ANTICIPATED. SUGGESTED USE IS WHERE FILL SLOPE IS 1:2 OR STEEPER AND LENGTH OF SLOPE EXCEEDS 25 FEET. AVOID WHERE THE DETAINED WATER MAY BACK INTO TRAVEL LANES OR OFF THE RIGHT OF WAY.
  1. DO NOT CONSTRUCT SILT FENCES ACROSS PERMANENT FLOWING WATERCOURSES. SILT FENCES ARE TO BE UPLAND LOCATIONS AND TURBIDITY BARRIERS USED AT PERMANENT BODIES OF WATER.
  1. WHERE USED AS SLOPE PROTECTION, SILT FENCE IS TO BE CONSTRUCTED ON 0% LONGITUDINAL GRADE TO AVOID CHANNELIZING RUNOFF ALONG THE LENGTH OF THE FENCE.

SILT FENCE DETAIL NOT TO SCALE

PARTIAL INLET

COMPLETED INLET

NOTE:

INSTALL FDOT INLET PROTECTION OR APPROVED EQUAL

INLET PROTECTION DETAIL NOT TO SCALE

TAMPA TREE PROTECTION DETAIL AND NOTES

1/4" = 1'-0"

  1. 3-inch layer of mulch (eucalyptus or city approved equivalent); no mulch shall be placed within one foot of the trunk.
  1. Grand Tree Protection Fence: 6-foot or 8-foot high chain link in metal frame sections; mount with stanchions or stell posts on movable core drilled concrete blocks, installed on 8' on center max spacing.
  1. Notice Sign: 8.5" x11" corrugated plastic warning with 2" high black lettering. Fasten to fence with plastic zip toes or similar. Locate one sign every 50' of along the fence.
  1. Maintain existing natural grade within the tree protection fence unless noted otherwise on the plans.
  1. Standard Tree Protection Fence: high density polyethylene fencing with 3.5-inch x 1.5-inch openings; color orange; attach to steel or wood posts installed at eight-foot on center max.
  1. 2x2x6' posts embedded a minimum of 24-inches (or similar approved post)

PRZ:

Protective Root Zone:

The entire surface and subsurface soil area encompassed by prescribed radius for protected, specimen, and grand trees.

See plan for fence extents, but typically the extents are as follows:

  • Palms: 3' offset FFT
  • Protected Trees (5- to 23-inch DBH): 10' offset from face of trunk (FFT)
  • Specimen Trees: (24- to 31-inch DBH):15' offset FFT
  • Grand Trees (32-inch DBH): 20' offset FFT

TREE PROTECTION NOTES

  1. Minimum protection standards shall be met for all protected trees, prior to commencement of any construction activities on a development site and/or in public or private right-of-way, in accordance with the tree protection graphics below.
  1. No changes to the predevelopment conditions within the approved protective root zone during the construction process.
  1. Protective barricades may be removed only to prepare the development site for final landscaping activities. During this activity only non-mechanical techniques may occur within the designated protective root zone. No alteration(s), of any kind, shall be made to any part of the tree (roots, trunk, canopy/crown), other than those that are approved by the Natural Resources Coordinator or designee, as part of the related permit.
  1. No parking or storing of vehicles, equipment, or materials is permitted within the minimum protective area, at any time.
  1. No site clearing or grading is permitted within the minimum protective area, other than those changes that are approved by the Natural Resources Coordinator or designee, as part of the related permit.
  1. All canopy pruning must Meet ANSI A300 pruning per "American National Standards for Tree Care Operations". ANSI. A300, current edition. Work should be planned and supervised by an ISA Certified Arborist.
  1. Root Pruning shall be performed to ANSI A300 standards; must be clean, severed cuts (not jagged or frayed). Root pruning shall be performed with specifically designed mechanical root pruning tools (Vermeer or Dosko) or hand pruners, loppers, hand saws, reciprocal saws, oscillating saws, or small chain saws. Trenchers, excavators, and backhoes shall not be used to prune or crush roots.
No.DATEREVISIONSNo.DATEREVISIONSDES: SEB
36DRN: BB
25CKD: JDM
14DATE: 05/21/25

CITY of TAMPA

Mobility Department

Stormwater Engineering Division

WOODMERE & LOIS AVENUE DRAINAGE IMPROVEMENTS TREE PROTECTION & SILT FENCE SHEET

SHEET

9

OF 9

Every printed table on this sheet, recovered as rows and cells.

Revision block

No. | DATE | REVISIONS | No. | DATE | REVISIONS | DE.