Common Wire Gauges ; 18. 0.0403. 6.385. 20.9 ; 16. 0.0508. 4.016. 13.2 ......
When working with electrical wiring, understanding the resistance of your wire is crucial. This article delves into the specifics of 16 AWG (American Wire Gauge) wire resistance per foot, helping you make informed decisions in your electrical projects.
AWG is a standard used to measure the diameter of electrical wires. It was developed in the 19th century to provide a consistent way to measure wire size. The higher the AWG number, the smaller the wire diameter. Understanding AWG is essential because it directly affects a wire's resistance, current-carrying capacity, and flexibility.
Resistance is a fundamental concept in electronics, measuring how much a material opposes the flow of electric current. In the context of wires, resistance is calculated using the formula: R = ρL/A, where R is the resistance, ρ (rho) is the resistivity of the material, L is the length of the wire, and A is the cross-sectional area of the wire.

For a 16 AWG copper wire, the resistivity (ρ) is approximately 1.68 x 10^-8 ohm-meters at 20°C. The cross-sectional area (A) can be calculated using the formula A = π(0.131" - 0.00159" * AWG)^2, where 0.131" is the diameter of a 0 AWG wire and 0.00159" is the reduction per AWG. For a 16 AWG wire, A is approximately 0.0000013 square meters.
Using these values, the resistance (R) of a 16 AWG copper wire per foot (L = 0.3048 meters) is approximately 1.07 ohms.
For quick reference, here's a table of approximate resistances for 16 AWG copper wire at various lengths:

| Length (feet) | Resistance (ohms) |
|---|---|
| 1 | 1.07 |
| 5 | 5.35 |
| 10 | 10.7 |
| 50 | 53.5 |
| 100 | 107 |
Understanding the resistance of your wire is vital for several reasons. It helps you determine voltage drops, heat generation, and current-carrying capacity. It also aids in selecting the right wire size for your electrical needs, ensuring safety and efficiency in your electrical systems.
<strong>Electrical Wire Gauges - HyperPhysics</strong><p>Common Wire Gauges ; 18. 0.0403. 6.385. 20.9 ; 16. 0.0508. 4.016. 13.2 ...</p>
<strong>Resistance of Copper Wire by AWG | Chart - Misumi USA</strong><p>22.01.2026 ... For example, values such as AWG 4 copper resistance in ohms per 1,000 feet ... 16, 2,583, 50.8, 4.016, 4.725, 13.17, 15.50, 7.82, 11.6. 17, 2,048 ...</p>
<strong>Wire Resistance Calculator - Cirris Inc</strong><p>05.06.2014 ... Wire Gauge (AWG). 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19 ... Ohms per 100 ft. Ohms per 10 ft. Ohms per 1 ft. House ...</p>
<strong>AWG table - conversion in mm, mm² and Ohm / km</strong><p>Conversion AWG table (American Wire Gauge). ✚ outside diameter Ø mm ✚ cross-section geometrical mm² ✚ conductor resistance Ohm / km.</p>
<strong>Stranded Wire Chart (AWG) - CDN</strong><p>AWG. Stranding. Approx. O.D.. Inches mm. Circular. Weight. D.C. Resistance D.C. Resistance. Mil. Square. Lbs/. Weight ohms/ ohms/. Area. Inches mm. 1000 Ft. KG/ ...</p>
<strong>Copper Wire - Electrical Resistance vs. Gauge</strong><p>Copper Wire - Electrical Resistance vs. Gauge. AWG Gauge*, Area (Circular Mils), Diameter ( mils, 1000th in), Electrical Resistance (Ohms/1000 ft), Weight</p>
<strong>WIRE GAUGES & STRANDINGS</strong><p>drawn wire is the American Wire Gauge (AWG). ... Example: #30 AWG wire is 100 CM (1/10 that of #20 AWG) and 100 ohms per 1,000 feet (10 times that of #20 AWG).</p>
<strong>DC Copper Cable Resistance Chart - Philatron</strong><p>Dc Copper Cable Resistance Ohms per 1,000 Feet ; 0000, 460.0, 211 600. 0.1662, 0.045 16 ; 000, 469.6, 167 800. .1318 .056 95 ...</p>
<strong>American wire gauge - Wikipedia</strong><p>... per 10000 ft. Because aluminum wire has a conductivity of approximately 61% of copper, an aluminum wire has nearly the same resistance as a copper wire that ...</p>
<strong>Wire Gauge - AWG, Amperage, Diameter Size, & Resistance Per ...</strong><p>07.12.2019 ... Very good up until your misapplication of V=IR. If you use that formula the way you present it, then a wire of only 10 feet would only ...</p>
<strong>Calculating the Resistance of a Wire</strong><p>Resistance Per 10 Ft (Ohms/10 Ft):, Resistance Per 100 Ft (Ohms/100 Ft): ... 16 AWG, 4.016 milliohms (mΩ), 40.16 milliohms (mΩ), 401.6 milliohms (mΩ), 4.016 ...</p>
<strong>Solid Copper Wire & Magnet Wire Data by AWG (4/0 to 24)</strong><p>Single Build Diameter. Heavy Build Diameter in mm circ. mils mm2. Ω/1000 ft. Ω/km in mm in mm. 0000 (4/0). 0.4600. 11.684. 211.2 kcmil. 107.0. 0.0490.</p>
<strong>Wire Resistance Calculator</strong><p>As well as resistivity, it is an intrinsic property of the material, but the conductivity units are "siemens per meter" ( S / m ). Electrical current can ...</p>
<strong>Copper wire tables - NIST Technical Series Publications</strong><p>It is for resistance in ohms per 1,000 feet, using No. 10 as a starting ... Ohms per Kilometer 16 at— at 20 °C at 20 °C. 0 °C. 20 °C. 25 °C. 50 °C. 75 °C.</p>
<strong>Wire Stranding Charts</strong><p>Additional allowances have to be made when the wires are cabled into a multi conductor cable. Wire. Stranding Charts. Solid and Stranded Conductor AWG Chart.</p>
<strong>Wire length by resistance : r/electricians - Reddit</strong><p>01.03.2024 ... There's a chart with resistance per 1000 feet, I think 12awg r90 is ... The 2020 NEC has chapter 9 table 8 (conductor properties) listing 12 AWG ...</p>
<strong>Wire Gauge,Diameter Resistance Table - DeviceCraft</strong><p>Ohms/Foot. Diameter. Ohms/Meter. AWG inches. Copper. Copper mm. Copper. 2. 0.25762 ... 16. 0.05082. 2027.33. 4.02. 0.00402. 1.2908. 0.01318. 17. 0.04526. 1607.75.</p>
<strong>Electrical Resistance of Copper Conductors (mm²)</strong><p>Electrical Resistance of Copper Conductors (AWG). Conductor. Section. (AWG). Section. (mm²). No. of. Wires. Single Wire. (mm) Dia. Max. Conductor Resistance. ( ...</p>
<strong>Wire Size Selection</strong><p>As a useful rule of thumb, remember that 10AWG wire has a resistance of about 1 milliohm per foot. Every time you step three AWG sizes, you double/half the ...</p>
<strong>Wire Resistance - Luca's Notes</strong><p>21.03.2025 ... AWG Copper Wire: Resistance Per 1 Ft (Ohms/Ft):, Resistance Per 10 Ft (Ohms/10 Ft): ; 0000 (4/0) AWG, 0.04901 milliohms (mΩ), 0.4901 milliohms ( ...</p>