AWG to mm² CONVERSION TABLE ... Multiple AWG choices — consult responsible engineer for required ampacity. AWG (American Wire Gauge) to mm2 (Millimeters squa...
When working with electrical wiring, it's crucial to understand the relationship between American Wire Gauge (AWG), millimeter squared (MM²), and ampacity. This guide will help you navigate the AWG to MM² chart, ensuring you select the right wire size for your electrical needs while adhering to safety standards.
American Wire Gauge (AWG) is a standard used to measure the diameter of electrical wires in North America. It's an inverse scale, meaning the higher the AWG number, the smaller the wire diameter. On the other hand, millimeter squared (MM²) is a metric unit used to measure the cross-sectional area of a wire. Understanding both systems is essential for international projects or when working with different suppliers.
Here's a simple AWG to MM² conversion chart to help you convert between the two systems:

| AWG | MM² |
|---|---|
| 12 | 2.05 |
| 14 | 1.63 |
| 16 | 1.31 |
| 18 | 1.03 |
| 20 | 0.82 |
| 22 | 0.65 |
| 24 | 0.52 |
| 26 | 0.41 |
| 28 | 0.32 |
| 30 | 0.25 |
This chart is vital for several reasons. Firstly, it helps you select the correct wire size for your electrical needs, ensuring your circuit can handle the required current. Secondly, it aids in international collaboration by allowing you to convert between imperial and metric units. Lastly, it promotes safety by preventing overloaded circuits, which can lead to fires and other hazards.
Ampacity refers to the maximum current a wire can safely carry without overheating. It's crucial to consider the wire's ampacity when selecting a wire size, as it ensures the wire can handle the expected load. The ampacity of a wire depends on its size, insulation type, and the ambient temperature.
Here's a simplified ampacity chart for common wire sizes in free air at 30°C (86°F), assuming PVC insulation:

| AWG/MM² | Ampacity (A) |
|---|---|
| 12/2.05 | 20 |
| 14/1.63 | 15 |
| 16/1.31 | 13 |
| 18/1.03 | 10 |
| 20/0.82 | 8 |
| 22/0.65 | 6 |
| 24/0.52 | 5 |
| 26/0.41 | 4 |
| 28/0.32 | 3 |
| 30/0.25 | 2.5 |
To select the right wire size, follow these steps:
Always adhere to local electrical codes and regulations when selecting wire sizes. If you're unsure, consult a licensed electrician or electrical engineer.
In conclusion, understanding the AWG to MM² chart and ampacity is essential for selecting the right wire size for your electrical needs. By following the guidelines in this article, you can ensure your circuits are safe and efficient.
<strong>AWG (American Wire Gauge) to mm2 (Millimeters squared ...</strong><p>AWG to mm² CONVERSION TABLE ... Multiple AWG choices — consult responsible engineer for required ampacity. AWG (American Wire Gauge) to mm2 (Millimeters squared) ...</p>
<strong>Cross Reference AWG to MM2 - Multi Cable Corporation</strong><p>Cross Reference AWG to MM2 ; 28, 0.08 ; 26, 0.14 ; 24, 0.25 ; 22, 0.34.</p>
<strong>Metric AWG to MM2 Conversion Chart - Top Cable</strong><p>02.10.2023 ... According to the chart, 2.5 mm² is approximately equivalent to 14 AWG. Why does the US use AWG? It has historical roots and remains the standard ...</p>
<strong>American Wire Gauge Chart and AWG Electrical Current Load Limits ...</strong><p>18.04.2023 ... AWG Wire size chart and ampacity table for design engineers ... Conductor cross section in mm2, Ohms per 1000 ft. Ohms per km, Maximum ...</p>
<strong>Metric-to-AWG Conversion Chart | Technical Resources</strong><p>Metric to AWG Conversion Table ; 95, 4/0 ; 120, 250MCM ; 150, 300MCM ; 185, 350MCM, 400MCM.</p>
<strong>AWG table - conversion in mm, mm² and Ohm / km</strong><p>AWG overview table ; 750, 25.4, 380 ; 600, 22.7, 304 ; 550, 21.7, 279 ; 500, 20.7, 253 ...</p>
<strong>AWG to MM2 Wire Gauge Size Chart | LEX Innovations</strong><p>The table below illustrates the conversion of AWG to MM2 (or MM2 to AWG) for easy conversion of wire gauge to mm2. Wire Size Conversion Chart - American Wire ...</p>
<strong>American wire gauge - Wikipedia</strong><p>Tables of AWG wire sizes ; 0000 (4/0) ; 0.4600 ; 11.684 ...</p>
<strong>American Wire Gauge “AWG” Chart – Wire Size & Ampacity Table.. 3/0</strong><p>09.03.2026 ... 4 AWG (21.1 mm²): Perfect for main feeder lines or very high-demand applications, rated for 70 AMPs. Always consult local electrical codes and ...</p>
<strong>Wire Gauge Chart Master Guide: AWG to mm² & Amps (2025)</strong><p>17.12.2025 ... Looking for the correct wire size? Access our expert Wire Gauge Chart (2025) with instant AWG to mm² conversions, NEC ampacity tables ...</p>
<strong>Wire AWG Size Conversion Calculator - Pinterest</strong><p>25.12.2023 ... American Wire Gauge "AWG" Chart - Wire Size & Ampacity Table · 1. Save · haud ; Awg Sizes & Properties of Electrical Cables / Conductors Magnetic ...</p>
<strong>What are HELU's awg cables? Converting awg into mm2 - Helukabel</strong><p>The regulations on electrical circuit protection and the NEC (National Electrical Code) standards are all based on ampacity according to AWG size. Although ...</p>
<strong>AWG - Wire Gauge Sizes: Current Ratings, Charts, Measurements ...</strong><p>The AWG table below is for a single, solid, round conductor. Because of the small gaps between the strands in a stranded wire, a stranded wire with the same ...</p>
<strong>AWG-IEC Wire Gauges - MetaTek</strong><p>11.03.2026 ... American Wire Gauge (AWG) and IEC (mm2) Copper wire sizes. AWG ... IEC mm2, Circular Mils, Amperes. Free Air, 70C PVC, In Wall, 70C PVC. 0.5 ...</p>
<strong>Awg MM2 PDF - Scribd</strong><p>NEC Table 310.15(B)(16) Ampacity Guide. PDF. 100% (1). NEC Table 310.15(B)(16) Ampacity Guide ... MM2 to AWG Wire Size Conversion Chart. 7 Seiten. AWG to mm ...</p>
<strong>Mm2 Ampacity Chart - hris.mohs.gov.sl</strong><p>AMPACITY CHART wire size Copper awg area mm2 VdI ampacity VdI aluminum ampacity 16 1.31 1 10 14. 2.08 2 15 12 3.31 3 20 10 5.26 5 30 don't use 8 8.37 8 55 6 ...</p>
<strong>American Wire Gauge "AWG" Chart - Wire Size & Ampacity Table</strong><p>The following AWG “American Wire Gauge” table shows the AWG Size and diameter in millimeter “mm” and inches in “in”, its cross sectional area in mm2, Inche2 and ...</p>
<strong>What cable size is required for a solar panel installation with a 30 ...</strong><p>25.06.2024 ... ⚡️ Key Takeaways from the chart: 14 AWG (2.0 mm²): Ideal for ... I see on the NEC ampacity table that for example a 2 AWG wire can ...</p>
<strong>American Wire Gauge Conductor Size Table - Solaris-Shop.com</strong><p>Complete American Wire Gauge (AWG) chart with wire sizes, diameter, resistance, ampacity and more ... Area (mm²), Resistance (Ω/1000ft), Resistance (Ω/km) ...</p>
<strong>AWG Tabelle</strong><p>LEITER. GEWICHT. Nr. nxAWG. nxDraht-Ø mm mm² mm. Ohm/ km kg/ km. AWG 36. 36 massiv massiv. 0.013. 0.127. 1460.0. 0.116. 36. 7/44. 7x0.05. 0.014. 0.152.</p>