Wire Gauge,Diameter Resistance Table. Wire Gauge. Diameter. Area /Cross. Ohms/1000 feet. Ohms/Foot. Diameter. Ohms/Meter. AWG inches. Copper. Copper mm. Copper....
When working with American Wire Gauge (AWG) wires, it's crucial to understand their resistance to ensure optimal performance and safety in your electrical circuits. This article provides a comprehensive guide to AWG wire resistance, focusing on ohms per foot, with a downloadable PDF chart for easy reference.
AWG wire resistance is primarily determined by the wire's cross-sectional area, which is inversely proportional to its gauge. As the AWG number increases, the wire's diameter decreases, leading to higher resistance. The resistance (R) of a wire can be calculated using the formula:
R = (ρL) / A

where ρ is the resistivity of the material (for copper, it's approximately 1.68 x 10^-8 ohm-meters), L is the length of the wire, and A is the cross-sectional area.
To simplify calculations, it's helpful to have a chart that provides resistance values in ohms per foot for various AWG sizes. Here's a table that you can use as a quick reference:
| AWG Size | Ohms per Foot |
|---|---|
| 12 | 0.00087 |
| 14 | 0.00130 |
| 16 | 0.00195 |
| 18 | 0.00293 |
| 20 | 0.00440 |
| 22 | 0.00660 |
| 24 | 0.01000 |
| 26 | 0.01500 |
You can download a printable PDF version of this chart here.

While the AWG size is the primary factor determining a wire's resistance, other factors can also influence it:
Temperature: Increased temperature can cause the wire's resistance to rise.
Length: Longer wires have higher resistance due to their increased length (L) in the resistance formula.
Material: Different materials have varying resistivities (ρ). For example, aluminum has a higher resistivity than copper.
When selecting an AWG wire, consider the required current, voltage drop, and the wire's length. Using the chart above, you can calculate the wire's resistance and ensure it meets your circuit's needs. For example, if you need a wire with a resistance of no more than 0.01 ohms per foot and are considering a 50-foot length, you could choose AWG 12 or larger, as they have resistances below this threshold.
Always remember that using a wire with too high a resistance can lead to excessive voltage drops, reduced performance, and even overheating. Conversely, using a wire with too low a resistance can result in short circuits and other safety hazards.
In conclusion, understanding AWG wire resistance is essential for designing safe and efficient electrical circuits. By using the provided chart and considering the factors that affect resistance, you can make informed decisions when selecting wires for your projects.
<strong>Wire Gauge,Diameter Resistance Table - DeviceCraft</strong><p>Wire Gauge,Diameter Resistance Table. Wire Gauge. Diameter. Area /Cross. Ohms/1000 feet. Ohms/Foot. Diameter. Ohms/Meter. AWG inches. Copper. Copper mm. Copper.</p>
<strong>WIRE GAUGES & STRANDINGS</strong><p>resistance of 40 ohms. (All values are ... Example: #30 AWG wire is 100 CM (1/10 that of #20 AWG) and 100 ohms per 1,000 feet (10 times that of #20 AWG).</p>
<strong>Wire Stranding Charts</strong><p>Solid and Stranded Conductor AWG Chart. AWG. Size. Total. Strands/. Strand Size ... The maximum resistance values are for the wire as a single conductor.</p>
<strong>Table 8 Conductor Properties - NECA IBEW Electricians</strong><p>(AWG or kcmil). Stranding. Overall. Copper. Area. Diameter. Diameter. Area ... These resistance values are valid only for the parameters as given. Using ...</p>
<strong>Wire Size Selection</strong><p>As a useful rule of thumb, remember that 10AWG wire has a resistance of about 1 milliohm per foot. Every time you step three AWG sizes, you double/half the ...</p>
<strong>Copper wire tables - NIST Technical Series Publications</strong><p>It is for resistance in ohms per 1,000 feet, using No. 10 as a starting point. A similar table might be made for mass in pounds per. 1,000 feet, or for cross ...</p>
<strong>Stranded Wire Chart (AWG) - CDN</strong><p>Stranded Wire Chart (AWG). AWG. Stranding. Approx. O.D.. Inches mm. Circular. Weight. D.C. Resistance D.C. Resistance. Mil. Square. Lbs/. Weight ohms/ ohms/.</p>
<strong>Wire Run Resistance Chart - AWS</strong><p>Wire Run. Length (feet). Wire Size (AWG) / Ω per foot. 18 / 0.00692. 16 / 0.00435. 14 / 0.00273. 12 / 0.00171. 10 / 0.00108. 8 / 0.000641. 20. 0.2768. 0.174.</p>
<strong>AWG Wire Gauge and Current Ratings | PDF - Scribd</strong><p>As gauge size increases from 0 to 40, resistance increases from 0.0983 to 10.49 ohms per 1000 feet, while maximum current capacity decreases from 245 to 9 amps ...</p>
<strong>Solid Copper Wire & Magnet Wire Data by AWG (4/0 to 24)</strong><p>currents to distribute near the surface of a conductor, which reduces the effective utilized conductor area and increases the effective resistance. If you ...</p>
<strong>magnet wire / winding wire engineering data handbook</strong><p>The nominal AWG bare wire diameters, in inches, in this table are ... NOTE: Conductor resistance per thousand feet (ohms). RECTANGULAR, BARE WIRE ...</p>
<strong>AWG Conversion - Alpha Wire</strong><p>CONDUCTOR CHART. AWG STRANDING. APPROX. O.D.. SQUARE. BARE COPPER TINNED COPPER. CIRCULAR. WEIGHT. D.C. RESISTANCE D.C. RESISTANCE. MIL. LBS./. OHMS/ OHMS/ OHMS ...</p>
<strong>copper wire tables - GovInfo</strong><p>resistance in ohms per 1,000 feet at 20° C is given approximately by combining formulas (1) and (3); or, in other terms. Feet per ohm=^j'^' (10). Similar ...</p>
<strong>Thermocouples - - Wire Size, Resistance Weight</strong><p>THERMOCOUPLE WIRE SIZE AND RESISTANCE TABLE. RESISTANCE IN OHMS PER DOUBLE FOOT AT 68°F. AWG. NO. DIAMETER. (inches). TYPE K. Chromel /. Alumel. Page 2. BASE ...</p>
<strong>Electrical Tech Note — 212 - Michigan State University</strong><p>... ohm•circular mils per foot which is the resistance of a one feet long ... In this case the resistance of the size 2 AWG copper wire will be smaller than 0.077 ...</p>
<strong>Electrical Resistance of Copper Conductors (mm²)</strong><p>Wire Dia. Max. Wire Dia. Class 5(mm). Class 6(mm). Max. Conductor Resistance (Ohm/km at 20 °C) ... (AWG). Section. (mm²). No. of. Wires. Single Wire. (mm) Dia.</p>
<strong>Table 8.pdf - Lori's Web</strong><p>For inquiries or to report unauthorized use, contact licensing@nfpa.org. Table 8 Conductor Properties. TABLES. CHAPTER 9. Conductors. Stranding.</p>
<strong>AWG to Metric Conversion Chart - Victron Energy</strong><p>AWG Number Ø [Inch] Ø [mm] Ø [mm²] Resistance [Ohm/m]. 4/0 = 0000. 0.460. 11.7. 107. 0.000161. 3/0 = 000. 0.410. 10.4. 85.0. 0.000203. 2/0 = 00. 0.365. 9.26.</p>
<strong>Copper Magnet Wire Data</strong><p>Copper Magnet Wire Data. SIZE. (AWG). BARE COPPER. DIAMETER (INCHES). RESISTANCE** (OHMS PER 1000 FT. AT 20˚C). FEET. PER. POUND. POUNDS. PER. 1,000 FT.</p>
<strong>Table 9 Alternating-Current Resistance and Reactance for 600-Volt ...</strong><p>Ohms to Neutral per 1000 Feet. Alternating-Current. Resistance for. Alternating ... (AWG Aluminum Steel. PVC Aluminum Steel. PVC Aluminum Steel. PVC Aluminum ...</p>