AWG (American Wire Gauge = Amerikanische Drahtlehre) ist die Kodierung für den Leiterquerschnitt. Sie kennzeichnet unter anderem elektrische Leitungen aus ......
In the realm of electrical engineering and wiring, two terms frequently encountered are American Wire Gauge (AWG) and square millimeters (mm²). Both are used to denote the size of electrical wires, but they originate from different measurement systems. This article delves into the relation between AWG and mm², providing a comprehensive understanding of these two units and how they interrelate.
AWG is a standard used primarily in North America to measure the diameter of electrical wire. It was established in 1857 and has since been widely adopted. The AWG system is based on a logarithmic scale, which means that each gauge size is approximately 1.12 times larger than the previous one. The smaller the AWG number, the larger the wire diameter.
Starting from AWG 0000 (the largest), the sizes decrease to AWG 40 (the smallest). For example, AWG 12 wire is smaller than AWG 10, but larger than AWG 14. This logarithmic scale makes it easy to understand the relationship between different AWG sizes.

On the other hand, mm² is a metric unit used to measure the cross-sectional area of electrical conductors. It's widely used in Europe and other parts of the world. The larger the mm² value, the larger the wire diameter and the more current it can safely carry.
Some common mm² sizes include 1.5 mm², 2.5 mm², 4 mm², and 6 mm². For instance, a 2.5 mm² wire has a larger diameter and can carry more current than a 1.5 mm² wire, but less than a 4 mm² wire.
The relationship between AWG and mm² is not linear, primarily due to the different measurement systems they originate from. However, there are conversion charts and formulas that can help convert from one unit to another. Here's a simple way to understand the relation:
It's essential to note that these conversions are approximate and can vary depending on the specific wire and its construction. Always consult a detailed conversion chart or formula for precise measurements.
| AWG | mm² |
|---|---|
| 10 | 6 |
| 12 | 4 |
| 14 | 2.5 |
| 16 | 1.5 |
This table provides a quick reference for common AWG to mm² conversions. However, it's crucial to remember that these are approximate values and should be used as a starting point for more precise calculations.
Understanding the relation between AWG and mm² is vital for several reasons. Firstly, it ensures that you're using the correct wire size for your electrical needs, which is crucial for safety and efficiency. Secondly, it helps in international communication and collaboration, as different regions use different measurement systems. Lastly, it provides a more comprehensive understanding of electrical wiring, which is a valuable skill in various industries.
In conclusion, while AWG and mm² are different measurement systems, they both serve the same purpose: to denote the size of electrical wires. Understanding their relation and how to convert between them is an essential skill for anyone working with electrical wiring.
<strong>Umrechnung von AWG - mm² - Umrechnungstabelle - Litze24.de</strong><p>AWG (American Wire Gauge = Amerikanische Drahtlehre) ist die Kodierung für den Leiterquerschnitt. Sie kennzeichnet unter anderem elektrische Leitungen aus ...</p>
<strong>Cross Reference AWG to MM2 - Multi Cable Corporation</strong><p>Cross Reference AWG to MM2 ; 28, 0.08 ; 26, 0.14 ; 24, 0.25 ; 22, 0.34.</p>
<strong>AWG (American Wire Gauge) to mm2 (Millimeters squared ...</strong><p>20. 0.52. 18. 0.82. 16. 1.31. 14. 2.08. 12. 3.31. 10. 5.26. 8. 8.36. 6. 13.3. 4. 21.2. 2. 33.6. 1. 42.4. 1/0. 53.5. 2/0. 67.4. 3/0. 85.0.</p>
<strong>Conversion table (AWG/mm/mm2) - Scankab</strong><p>Here you will find our converting table so you easily can compare AWG (American Wire Gauge) with de approximately sizes i mm and mm2. Download Convesion ...</p>
<strong>AWG table - conversion in mm, mm² and Ohm / km</strong><p>In the North American economic area, the dimensions of copper conductors for power and telecommunication purposes are mostly given in AWG (American Wire ...</p>
<strong>AWG Tabelle, Durchmesser und Widerstand</strong><p>AWG ist der genaue entsprechende Wert in mm² + Durchmesser in mm. Die nachfolgende AWG Tabelle zeigt eine Übersicht der gängigen AWG Werte in mm².</p>
<strong>AWG to Metric Conversion Chart - Victron Energy</strong><p>AWG Number Ø [Inch] Ø [mm] Ø [mm²] Resistance [Ohm/m]. 4/0 = 0000. 0.460. 11.7. 107. 0.000161. 3/0 = 000. 0.410. 10.4. 85.0. 0.000203. 2/0 = 00. 0.365. 9.26.</p>
<strong>AWG to mm2 - American Wire Gauge vs. Square mm Cross Section</strong><p>AWG is the exact corresponding value in mm² + diameter in mm. The following AWG table shows an overview of the common AWG values in mm². The table comparing ...</p>
<strong>Umrechnungstabellen - Zuordnung von Leiterquerschnitten (AWG</strong><p>MCM metrischer. Leiterquerschnitt mm2 vergleichbarer. Leiterquerschnitt mm2. 27. 0,102. –. 250. 127. 120. 26. 0,128. 0,14. 300. 152. 150. 25. 0,163.</p>
<strong>Metric AWG to MM2 Conversion Chart - Voltimum UK</strong><p>23.11.2023 ... If you work in a sector involving the measurement of cables or wires, you may have come across the terms AWG and mm2. Both units of measurement ...</p>
<strong>Metric-to-AWG Conversion Chart | Technical Resources</strong><p>Metric to AWG Conversion Table ; 0.34, 22 ; 0.38, 21 ; 0.5, 20 ; 0.75, 19.</p>
<strong>American wire gauge - Wikipedia</strong><p>American Wire Gauge (AWG) is a logarithmic stepped standardized wire gauge system used since 1857, predominantly in North America, for the diameters of ...</p>
<strong>Metric AWG to MM2 Conversion Chart - Top Cable</strong><p>02.10.2023 ... Is AWG the same as mm²? No. AWG is a gauge number, while mm² is a direct measurement of cross-sectional area. They are correlated but not the ...</p>
<strong>Conversion Chart, AWG to mm2 General Measuring Units</strong><p>This cross reference list shows equivalent nominal values. Actual cross sections may vary. AWG mm2. AWG mm2. AWG mm2. 30.</p>
<strong>AWG to MM2 Wire Gauge Size Chart | LEX Innovations</strong><p>As a general rule of thumb, for every 6 gauge decrease, the wire diameter doubles, and every 3 gauge decrease doubles the cross-sectional area. The table below ...</p>
<strong>AWG conversion table - TNT-Audio</strong><p>... relation between the mysterious AWG number and the cross-section in mm2. May we leave you alone to face this trouble? Certainly not! So here it is an useful ...</p>
<strong>What is the difference between American Wire Gauge (AWG) and ...</strong><p>25.09.2022 ... Much of the world just uses mm². . . Very easy and can cover any size.. . . . The American use AWG for small wires, and number backwards, so ...</p>
<strong>Metric AWG to MM2 Conversion Chart - Mueller Group</strong><p>MM2 to AWG/MCM conversion chart included in PDF. Have a question about this information or a specific wire or cable? Need help figuring out if a wire meets ...</p>
<strong>AWG in mm² calculator - Calculate wire cross-section | CiS</strong><p>What Is American Wire Gauge (AWG)? · What Does Gauge Mean in Relation to Wire? · Why Is the Wire Diameter Important? · Important Factors When Selecting the Correct ...</p>
<strong>AWG in mm² | How to convert | Simply explained - Stecker Express</strong><p>Find out how to convert AWG to millimetres to accurately determine your cable and wire diameters. Read the guide now.</p>