Cross Reference AWG to MM2. AWG, mm2. 30, 0.05. 28, 0.08. 26, 0.14. 24, 0.25. 22, 0.34. 21, 0.38. 20, 0.50. 18, 0.75. 17, 1.0. 16, 1.5. 14, 2.5. 12, 4.0. 10 .....
In the realm of electrical engineering and electronics, understanding wire gauge and its corresponding cross-sectional area is crucial. The American Wire Gauge (AWG) system is widely used, but many applications require dimensions in square millimeters (mm²). This article will guide you through converting 21 AWG to mm², explaining the process, and providing a handy conversion table.
AWG is a logarithmic unit of measurement for the diameter of a circular wire. It was developed in the 19th century to standardize wire sizes. On the other hand, mm² is a unit of area, representing the cross-sectional area of a wire in square millimeters. To convert AWG to mm², we need to determine the wire's cross-sectional area using its AWG value.
Converting AWG to mm² is essential for several reasons. Firstly, many international standards and regulations use mm² for wire sizes. Secondly, it's crucial for calculating electrical parameters like current-carrying capacity and resistance. Lastly, it helps in comparing wire sizes across different systems.

To convert 21 AWG to mm², we'll use the following formula, which is based on the AWG to diameter conversion and the area calculation for a circle:
Area (mm²) = (π * (Diameter (mm))²) / 4
First, we need to find the diameter of a 21 AWG wire. The diameter (D) in millimeters for a given AWG (n) can be calculated using the formula:

D = 0.127 * (92 - 2 * n)
Plugging in 21 for n, we get:
D = 0.127 * (92 - 2 * 21) = 0.508 mm
Now, we can calculate the cross-sectional area:
Area (mm²) = π * (0.508 mm)² / 4 ≈ 0.206 mm²
| AWG | Diameter (mm) | Area (mm²) |
|---|---|---|
| 21 | 0.508 | 0.206 |
| 22 | 0.462 | 0.177 |
| 23 | 0.423 | 0.141 |
| 24 | 0.388 | 0.117 |
| 25 | 0.357 | 0.099 |
Knowing that 21 AWG wire has a cross-sectional area of approximately 0.206 mm² can help in various applications. For instance, it can help you:
Always remember that while converting AWG to mm², it's essential to use the correct formulas and values to ensure accurate results. Understanding these conversions can significantly improve your electrical engineering and electronics projects.
<strong>Cross Reference AWG to MM2 - Multi Cable Corporation</strong><p>Cross Reference AWG to MM2. AWG, mm2. 30, 0.05. 28, 0.08. 26, 0.14. 24, 0.25. 22, 0.34. 21, 0.38. 20, 0.50. 18, 0.75. 17, 1.0. 16, 1.5. 14, 2.5. 12, 4.0. 10 ...</p>
<strong>Umrechnung von AWG - mm² - Umrechnungstabelle - Litze24.de</strong><p>AWG - Umrechnungstabelle ; 2, 33,62, 35 ; 3, 26,67 ; 4, 21,15, 25 ; 5, 16,75.</p>
<strong>AWG Tabelle, Durchmesser und Widerstand</strong><p>AWG ist der genaue entsprechende Wert in mm² + Durchmesser in mm. Die nachfolgende AWG Tabelle zeigt eine Übersicht der gängigen AWG Werte in mm².</p>
<strong>AWG (American Wire Gauge) to mm2 (Millimeters squared ...</strong><p>AWG to mm² CONVERSION TABLE. AWG/kcmil. [mm²]*. 20. 0.52. 18. 0.82. 16. 1.31. 14 ... AWG (American Wire Gauge) to mm2 (Millimeters squared) Conversion. SPEC A185.</p>
<strong>Umrechnungstabellen - Zuordnung von Leiterquerschnitten (AWG</strong><p>21,2. –. 3. 26,7. 25. 2. 33,6. 35. 1. 42,4. –. 1/0. 53,4. 50. 2/0. 67,5. 70. 3/0. 85. 95. 4 ... 645,1 mm2. 1 cu. In. 16,386 cm3. 1 pint. 0,568 l. 1 grain. 0,059 g.</p>
<strong>AWG table - conversion in mm, mm² and Ohm / km</strong><p>Conversion AWG table (American Wire Gauge). ✚ outside diameter Ø mm ... 34.8. 21, 0.724, 0.412, 43.6. 22, 0.643, 0.324, 55.2. 23, 0.574, 0.259, 69.2. 24, 0.511 ...</p>
<strong>AWG to Metric Conversion Chart - Victron Energy</strong><p>AWG Number Ø [Inch] Ø [mm] Ø [mm²] Resistance [Ohm/m]. 20. 0.0320 0.812. 0.518. 0.0333. 21. 0.0285 0.723. 0.410. 0.0420. 22. 0.0253 0.644. 0.326. 0.0530. 23.</p>
<strong>Metric AWG to MM2 Conversion Chart - Mueller Group</strong><p>Metric AWG to MM2 Conversion Chart ; 26, 0.14 ; 24, 0.25 ; 22, 0.34 ; 21, 0.38.</p>
<strong>AWG in mm²: Wie umrechnen | Einfach erklärt - Stecker Express</strong><p>AWG Strombelastbarkeit ; 3, 26,65, 80,00 A ; 4, 21,14, 70,00 A ; 6, 13,29, 55,00 A ; 8, 8,35, 40,00 A ...</p>
<strong>AWG Tabelle</strong><p>mm² mm. Ohm/ km kg/ km. AWG 36. 36 massiv massiv. 0.013. 0.127. 1460.0. 0.116. 36 ... 259/21. 259x0.724. 106.626. 13.259. 0.16. 948.97. 4/0. 427/23. 427x0.574.</p>
<strong>AWG-Umrechner | Farnell Österreich</strong><p>... [mm2], Circular Mil Area [CMA], and more. Simply enter the known measurement ... 21, 0.0285, 0.723, 0.810, 0.410, 42.00, 12.80, 1.2, 33 K Hz. 22, 0.0253, 0.644 ...</p>
<strong>AWG Tabelle – AWG in mm2 umrechnen - HEW-Kabel</strong><p>AWG steht für American Wire Gauge und bedeutet tatsächlicher Kabel-Querschnitt in mm² & Leiterwiderstand. HEW nutzt dahingehend die untenstehende Liste. Diese ...</p>
<strong>AWG - mm² Umrechnungstabelle - KabelForum</strong><p>AWG - mm² Umrechnungstabelle. ... 21, 0.723, 0.412. 22, 0.644, 0.325. 23, 0.573, 0.259. 24, 0.455, 0.205. 25, 0.405, 0.163.</p>
<strong>AWG to mm2 - ALVA Industries</strong><p>AWG to mm2 Conversion Chart. AWG, Diameter (mm), Area (mm²). 0000, 11.684 ... 21, 0.723, 0.411. 22, 0.644, 0.326. 23, 0.573, 0.258. 24, 0.511, 0.205. 25, 0.455 ...</p>
<strong>Conversion Chart, AWG to mm2 General Measuring Units</strong><p>21. 0.38. 2. 35. 1000 kcmil. 500. 20. 0.50. 1. 50. 18. 0.75. 17. 1.00. 2/0. 70. 16. 1.50. 3/0. 95. 14. 2.50. 4/0. 120. Length. Equivalent. Weight. Equivalent.</p>
<strong>American wire gauge - Wikipedia</strong><p>9.266, 2.74, 1.08, 133, 67.4, 0.2557, 0.07793, 145, 175, 195, 2.3 kA, 21 kA, 115 kA. 0 (1 ... Interactive Wire Size and Voltage Drop Calculator (AWG/mm²) — Tool ...</p>
<strong>Metric-to-AWG Conversion Chart | Technical Resources</strong><p>Metric to AWG Conversion Table. Metric Size (mm2 cross-sectional area), AWG Wire Gauge Size. 0.05, 30. 0.08, 28. 0.14, 26. 0.25, 24. 0.34, 22. 0.38, 21. 0.5, 20.</p>
<strong>AWG to mm2 - American Wire Gauge vs. Square mm Cross Section</strong><p>American Conductor Stranding - AWG Table ; 3, 26,7, 5,83 ; 4, 21,2, 5,19 ; 5, 16,8, 4,62 ; 6, 13,3, 4,11 ...</p>
<strong>Conversion table - AWG - Scankab</strong><p>mm2. Kg./km. 4/0. 11,684. 107,15. 953. 3/0. 10,404. 84,95. 756. 2/0. 9,266. 67,49. 599. 1 ... 21. 0,723. 0,4106. 3,65. 22. 0,644. 0,3257. 2,89. 23. 0,573. 0,2579.</p>
<strong>CORDIAL Cables - AWG-Tabelle</strong><p>08.07.2021 ... 21,8. 7,32. 1.00 mm². 7/26. 7x0,404. 0,897. 1,219. 19,2. 7,98. 16/30. 16x0,254. 0,811. 1,194. 21,3. 7,22. 19/30. 19x0,254. 0,963. 1,245. 17,9. 8 ...</p>