Starts or ends a station-based test.

Description

This pytest initializes (or terminates) the DUT connection in a station-based test, and validates (or invalidates) related device info. This pytest is mainly used as the first and last pytest to wrap around a sequence of station-based tests.

In more detail, if the argument start_station_tests is set to True, this pytest performs following initialization steps: 1. Clear DUT info. 2. Clear serial numbers from device data. 3. Wait for DUT being connected.

On the other hand, if the argument start_station_tests is set to False, this pytest performs following cleanup steps: 1. Wait for DUT being disconnected. 2. Clear DUT info. 3. Clear serial numbers from device data.

Test Procedure

If argument start_station_tests is set to True, it waits until the DUT is connected.

Otherwise, if argument start_station_tests is set to False, it waits until the DUT is disconnected.

Dependency

Depend on Device API (cros.factory.device.device_utils) to create a DUT interface, and monitor if DUT is connected.

Examples

To start a sequence of station-based tests, this pytest can be used as the first pytest, add this in test list:

{
  "pytest_name": "station_entry"
}

If the following pytests should be started until spacebar is hit:

{
  "pytest_name": "station_entry",
  "args": {
    "prompt_start": true
  }
}

To gracefully terminate a sequence of station-based tests:

{
  "pytest_name": "station_entry",
  "args": {
    "start_station_tests": false
  }
}

Please refer to station_based.test_list.json and STATION_BASED.md about how to do station based testing.

Test Arguments

Name

Type

Description

start_station_tests

bool

(optional; default: True) To start or stop the factory station tests.

prompt_start

bool

(optional; default: False) Prompt for spacebar before starting test.

timeout_secs

int, None

(optional; default: None) Timeout for waiting the device. Set to None for waiting forever.

disconnect_dut

bool

(optional; default: True) Ask operator to disconnect DUT or not

load_dut_storage

bool

(optional; default: True) To load DUT storage into station session (DeviceData).

invalidate_dut_info

bool

(optional; default: True) To invoke dut.info.Invalidate() or not

clear_serial_numbers

bool

(optional; default: True) To invoke device_data.ClearAllSerialNumbers() or not

wait_goofy

bool

(optional; default: True) wait until we can connect to goofy