Conversion AWG table (American Wire Gauge). ✚ outside diameter Ø mm ✚ cross-section geometrical mm² ✚ conductor resistance Ohm / km....
Ever wondered about the electrical resistance of a 22 AWG (American Wire Gauge) cable? Whether you're a seasoned electrician, a DIY enthusiast, or simply curious about the technical aspects of electrical wiring, understanding the resistance of a 22 AWG cable is crucial for ensuring safety and efficiency in your electrical systems. Let's delve into the world of electrical resistance and explore the intricacies of 22 AWG cables.
Before we dive into the specifics of 22 AWG cables, it's essential to have a solid understanding of electrical resistance. In simple terms, electrical resistance is the opposition to the flow of electric current through a material. It's measured in ohms (Ω) and is directly proportional to the length of the conductor and inversely proportional to its cross-sectional area. The formula for calculating resistance (R) is:
R = ρL / A

where ρ (rho) is the resistivity of the material, L is the length of the conductor, and A is the cross-sectional area.
A 22 AWG cable is a type of electrical cable that adheres to the American Wire Gauge standard. The AWG system is a logarithmic scale used to measure the diameter of round wires. A higher AWG number indicates a smaller wire diameter. A 22 AWG cable has a diameter of approximately 0.643 mm (0.0253 inches) and is commonly used for low-voltage applications, such as powering LED lights, small motors, and electronic circuits.
22 AWG cables come in various sizes and conductor materials. The most common types are:

The conductor material also affects the cable's resistance. Common conductor materials include copper, aluminum, and silver. Copper is the most commonly used due to its excellent conductivity, affordability, and wide availability.
Now that we understand the basics of electrical resistance and 22 AWG cables let's calculate the resistance of a 22 AWG cable. We'll use the formula mentioned earlier and assume a copper conductor, as it's the most common.
The resistivity (ρ) of copper at 20°C is approximately 1.68 x 10^-8 ohm-meters. The cross-sectional area (A) of a 22 AWG cable can be calculated using the formula for the area of a circle (A = πr^2), where r is the radius of the conductor. The radius of a 22 AWG cable is half of its diameter, which is approximately 0.3215 mm. Plugging these values into the formula, we get:
A = π * (0.3215 mm)^2 ≈ 0.3307 mm^2
Now, let's calculate the resistance (R) of a 100-meter length of 22 AWG cable:
R = (1.68 x 10^-8 Ω-m) * (100 m) / (0.3307 mm^2) ≈ 0.508 Ω
So, a 100-meter length of 22 AWG copper cable has a resistance of approximately 0.508 ohms.
It's also useful to know the resistance per foot of a 22 AWG cable. There are approximately 3.28084 feet in a meter. Using this conversion factor, we can calculate the resistance per foot:
R_per_foot = (0.508 Ω) / (3.28084 ft/m) ≈ 0.1547 Ω/ft
So, a single foot of 22 AWG copper cable has a resistance of approximately 0.1547 ohms.
While we've calculated the resistance of a 22 AWG cable under ideal conditions, several factors can affect its resistance in real-world applications:
To help you quickly reference the resistance of 22 AWG cables, we've created a simple chart for copper cables at 20°C:
| Length | Resistance (Ω) | Resistance (Ω/ft) |
|---|---|---|
| 10 m | 0.0508 | 0.1547 |
| 50 m | 0.2540 | 0.1547 |
| 100 m | 0.5080 | 0.1547 |
| 500 m | 2.5400 | 0.1547 |
| 1000 m | 5.0800 | 0.1547 |
This chart provides the resistance of 22 AWG copper cables for various lengths at 20°C. Keep in mind that these values are approximate and can vary based on the factors mentioned earlier.
Now that we've discussed the resistance of 22 AWG cables, let's explore when to use them. Due to their small diameter and relatively high resistance, 22 AWG cables are best suited for low-voltage, low-current applications. Some common uses include:
However, it's essential to consider the voltage drop and heat generation in your specific application. Using a cable with too high a resistance can lead to excessive voltage drop, reduced performance, and even safety hazards. Always choose the appropriate cable size for your needs.
In conclusion, understanding the resistance of a 22 AWG cable is crucial for ensuring safe and efficient electrical systems. By calculating and considering the factors affecting cable resistance, you can make informed decisions when selecting and using 22 AWG cables in your projects. Whether you're a seasoned electrician or a DIY enthusiast, having a solid grasp of electrical resistance will serve you well in your endeavors.
<strong>AWG table - conversion in mm, mm² and Ohm / km</strong><p>Conversion AWG table (American Wire Gauge). ✚ outside diameter Ø mm ✚ cross-section geometrical mm² ✚ conductor resistance Ohm / km.</p>
<strong>Electrical Wire Gauges - HyperPhysics</strong><p>Common Wire Gauges ; 22. 0.0254. 16.14. 52.7 ; 20. 0.0320. 10.15. 33.2 ...</p>
<strong>AWG to mm2 - American Wire Gauge vs. Square mm Cross Section</strong><p>Cable sizes - AWG to mm2 Table: AWG Number, Cable Cross Section in mm², Outer Diameter Ø mm, Conductor Resistance in Ohm/km ... 22,7, 0,061. 550, 279, 21,7, 0,066.</p>
<strong>AWG to Metric Conversion Chart - Victron Energy</strong><p>... Resistance [Ohm/m]. 4/0 = 0000. 0.460. 11.7. 107. 0.000161. 3/0 = 000. 0.410. 10.4 ... 22. 0.0253 0.644. 0.326. 0.0530. 23. 0.0226 0.573. 0.258. 0.0668. 24.</p>
<strong>AWG Tabelle</strong><p>AWG 20. AWG 18. AWG 16. AWG 22. AWG 30. AWG 28. AWG 27. AWG 26. AWG 36. AWG 34. AWG 32. AWG 24. AWG Tabelle. Seite 1/2. Page 2. AWG. AWG. AUFBAU. LEITER.</p>
<strong>Resistance of Copper Wire by AWG | Chart - Misumi USA</strong><p>22.01.2026 ... A wire resistance gauge like AWG is based on conductor diameter, so ... 22, 642.4, 25.3, 16.14, 19.00, 52.96, 62.33, 1.95, 2.90. 23, 509.5, 22.6 ...</p>
<strong>Standard DC resistance of conductor - Cableizer</strong><p>26 AWG, 0.128, 138, 143, 225, 140, 150, 230. 24 AWG, 0.205, 85.9, 89.3, 141, 87.6, 94.2, 144. 22 AWG, 0.324, 54.3, 56.4, 88.9, 55.4, 59.4, 90.9. 0.5 mm 2 ^2 ...</p>
<strong>Wire Resistance Calculator - Cirris Inc</strong><p>05.06.2014 ... Wire Gauge (AWG). 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 ...</p>
<strong>Electrical Resistance of Copper Conductors (mm²)</strong><p>Electrical Resistance of Copper Conductors (AWG). Conductor. Section. (AWG). Section. (mm²). No. of. Wires. Single Wire. (mm) Dia. Max. Conductor Resistance. ( ...</p>
<strong>22 AWG Wire FAQ: Specifications, Current, Power, and Applications</strong><p>05.09.2025 ... The current carrying capacity of a 22 AWG wire is typically between 0.9A and 3A. In free air: 2-3A. In cable bundles or ducts: 0.9-1.5A is ...</p>
<strong>Stranded Wire Chart (AWG) - CDN</strong><p>D.C. Resistance D.C. Resistance. Mil. Square. Lbs/. Weight ohms/ ohms/. Area ... 7/22. ,073. 1.8542. 4480.00 .0035. 2.2848. 13.56. 20.179. 2.31. 7.58. 14. 19/27.</p>
<strong>Wire Gauge, Resistance, Cross Section & Current Table | Technicals</strong><p>Cable excellence engineered through quality. Stranding and Resistance ... Change of 3 AWG Numbers Doubles Resistance and Halves Weight. 3. Properties of ...</p>
<strong>American wire gauge - Wikipedia</strong><p>Rules of thumb ; 1 Ω · for 10 AWG, ; 10 Ω · for 20 AWG, ; 100 Ω · for 30 AWG, and so on. · For an arbitrary gauge n, it is approximately 10 n/10 Ω per 10000 ft.</p>
<strong>Would a 22AWG wire be fine for my simple 5V Power supply circuit?</strong><p>16.04.2024 ... In the list above, for AWG22, the resistance is listed as 52.96 mOhm per meter or 16.14 mOhm per ft. Let's say you want to power a device that ...</p>
<strong>AWG Table – American Strand Design - HEW-Kabel</strong><p>AWG means American Wire Gauge and represents the actual cable cross-section in mm² & conductor resistance. ... 22, 0,355, 56,1, 52,1, 54,4. 0,382, 53,1, 49,5, 52, ...</p>
<strong>DC Copper Cable Resistance Chart - Philatron</strong><p>22, 25.35, 642.4 .000 504 6, 14.87, 15.83, 16.14, 16.46, 18.05, 19.63. 23, 22.57, 509.5 .000 400 2, 18.76, 19.96, 20.36, 20.76, 22.76, 24.76. 24, 20.10, 404.0 .</p>
<strong>Copper Wire - Electrical Resistance vs. Gauge</strong><p>8.21, 3.90. 20, 1020, 32, 10.4, 11.9, 3.09. 21, 810, 13.1, 2.45. 22, 642, 25.3, 16.5 ... American Wire Gauge (AWG) is a U.S. standard for wire conductor size. The ...</p>
<strong>Wire Data Stranded Tinned Copper</strong><p>Standard Wire & Cable Co. design, engineer, and manufacture commercial, military, and industrial electronic and electrical wire and cable.</p>
<strong>Wire Resistance Calculator</strong><p>Resistivity in a superconductor drops sharply to zero, and thus the conductivity approaches infinity. We can say that it is a perfect conductor. Conductance ...</p>
<strong>AWG Wire Gauge Chart: Sizes, Diameter, Resistance & Ampacity ...</strong><p>23.10.2023 ... 20 – 22, 0.9–1.5A, Small motors, sensors, electronics, speaker wire. 24 – 26, 0.36–0.58A, Ethernet cable, telephone, data cable, patch cables ...</p>